This kit comes with everything you need to start monitoring power quality. Use it to accurately measure single to 3-phase lines.
This kit comes with everything you need to start monitoring power quality. Use it to accurately measure single to 3-phase lines.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
Hioki's state-of-the-art PW3198-90 Power Quality Analyzer Kit with Software is ideal for handling all of your power monitoring needs. Instead of using more than 1 device to measure voltage, current, power and more, you can bring Hioki's versatile, portable analyzer with you to any job. Plus, this kit comes with software and a USB cable, so you can easily transfer your power quality data to a compatible PC for viewing, analysis and eventual report writing. CE compliant.
Features
Measurement Item | Voltage, current, power, EVENT |
Line Type | Single phase 2-wire, 3-wire; 3-phase 3-wire, 4-wire; 1 extra input channel |
Input Channel Amount | 4 voltage, 4 current |
Input Method | Voltage: isolated and differential inputs; current: insulated clamp-on sensors |
Sensor Compatibility | Clamp sensors with fs = 0.5 V output at rated current input; units with rate of 0.1, 1, 10 or 100 mV/A |
Range | Voltage: 600 V rms, 6 kV peak; current: 500 mA to 5 kA AC (depends on selected sensor); power: 300 W to 3 MW (determined automatically based on voltage and current range in use) |
Accuracy | Voltage: ±0.1% of nominal voltage; current and power: ±0.2% rdg, ±0.1% fs plus current sensor accuracy |
Interface | SD/SDHC card, RS-232C, LAN (HTTP server function), USB 2.0 |
Display | 6.5" (16.51 cm) TFT color LCD (640 x 480 dots) |
Maximum Recording Period | 1-week repeated recording: 55 weeks; 1-day repeated recording: 55 days; no repeated recording: 35 days |
Event Recording Maximum | Repeated recording on: 55,000 events; repeated recording off: 1,000 events |
Memory | 2 to 32 GB SD/SDHC memory cards |
Maximum Rated Power | 15 VA (when not charging, except AC adapter); 35 VA (when charging, except AC adapter) |
Power Supply | Z1002 AC adapter: 12 V DC, rated power supply 100 to 240 V AC, 50/60 Hz); Z1003: NiMH 7.2 V DC, 4,500 mAh |
Compliance | CE |
Product Length | 2.68" (68 mm) |
Product Width | 11.81" (300 mm) |
Product Height | 8.31" (211 mm) |
Product Weight | 91.7 oz (2.6 kg) including battery pack |
Measurement Item | Voltage, current, power, EVENT |
Line Type | Single phase 2-wire, 3-wire; 3-phase 3-wire, 4-wire; 1 extra input channel |
Input Channel Amount | 4 voltage, 4 current |
Input Method | Voltage: isolated and differential inputs; current: insulated clamp-on sensors |
Sensor Compatibility | Clamp sensors with fs = 0.5 V output at rated current input; units with rate of 0.1, 1, 10 or 100 mV/A |
Range | Voltage: 600 V rms, 6 kV peak; current: 500 mA to 5 kA AC (depends on selected sensor); power: 300 W to 3 MW (determined automatically based on voltage and current range in use) |
Accuracy | Voltage: ±0.1% of nominal voltage; current and power: ±0.2% rdg, ±0.1% fs plus current sensor accuracy |
Interface | SD/SDHC card, RS-232C, LAN (HTTP server function), USB 2.0 |
Display | 6.5" (16.51 cm) TFT color LCD (640 x 480 dots) |
Maximum Recording Period | 1-week repeated recording: 55 weeks; 1-day repeated recording: 55 days; no repeated recording: 35 days |
Event Recording Maximum | Repeated recording on: 55,000 events; repeated recording off: 1,000 events |
Memory | 2 to 32 GB SD/SDHC memory cards |
Maximum Rated Power | 15 VA (when not charging, except AC adapter); 35 VA (when charging, except AC adapter) |
Power Supply | Z1002 AC adapter: 12 V DC, rated power supply 100 to 240 V AC, 50/60 Hz); Z1003: NiMH 7.2 V DC, 4,500 mAh |
Compliance | CE |
Product Length | 2.68" (68 mm) |
Product Width | 11.81" (300 mm) |
Product Height | 8.31" (211 mm) |
Product Weight | 91.7 oz (2.6 kg) including battery pack |