Hioki PQ3198 Power Quality Analyzer-


Downloads: datasheet manual

Hioki PQ3198 Power Quality Analyzer

Model: 3198 | Order No: PQ3198

Investigate power characteristics and analyze the causes of problems with this power quality analyzer that simultaneously measures all waveforms of power, harmonic, and error events. In addition, this power quality analyzer has a broadband voltage range of up to 80 kHz.

Investigate power characteristics and analyze the causes of problems with this power quality analyzer that simultaneously measures all waveforms of power, harmonic, and error events. In addition, this power quality analyzer has a broadband voltage range of up to 80 kHz.

Your Price $8939.00 USD
Availability 5 to 6 Weeks
Quantity

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 3198 Power Quality Analyzer

Traceable Calibration Certificate Icon

Traceable Calibration Certificate for your 3198 Power Quality Analyzer

Hioki 3198 Offers

Featuring continuous gapless recording and high accuracy, use the Power Quality Analyzer to verify power problems in accordance with the IEC61000-4-30 Class A Standard.

Features

  • CAT IV 600V - safe enough for incoming power lines
  • Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz
  • Wide dynamic range from low voltages up to 1300V (3P4W line-to-line voltage)
  • Maximum 6000V transient overvoltage up to 700kHz
  • International power quality measurement standard IEC 61000-4-30 Edition 2 Class A
  • LAN, USB and SD card interfaces
  • Optional GPS BOX for synchronizing multiple devices

Applications

  • Power quality troubleshooting in industrial and commercial electrical systems

The number of power supply problems is increasing as power systems are becoming more and more complicated - all due to the rising use of power electronics devices plus a growing installed base of large systems and distributed power supplies. The quickest way to approach these problems is to understand the situation quickly and accurately. The Power Quality Analyzer is ready to effectively solve your power supply problems.

  • EV charger and inverter testing for power quality and efficiency verification

The unit can measure all waveforms of power, harmonic, and error events simultaneously. When a problem occurs with the equipment or system on your site, the analyzer will help you detect the cause of the problem early and solve it quickly. You can depend on the PW3198 to monitor all aspects of your power supplies.

  • UPS and renewable energy monitoring for harmonics, voltage events, and power anomalies

Hioki 3198 Specifications

Measurement Line Type Single-phase two-wire
Single-phase three-wire
Three-phase three-wire or three-phase three-wire plus one extra input channel for voltage, current, power measurement (AC or DC measurement)
Ranges Voltage: 600 Vrms, 6.0000 kV peak (transient)
Current: 100 A
Power: 300 W to 3.0000 MW (determined automatically based on voltage and current range in use)
Basic Accuracy Voltage: ±0.1% of nominal voltage
Current: ±0.1% rdg, ±0.1% f.s. + current sensor accuracy
Active power: ±0.2% rdg, ±0.1% f.s. + current sensor accuracy
Measurement Items 1. Transient voltage: 2 MHz sampling
2. Frequency cycle: Calculated as one cycle, 40 to 70 Hz
3. Voltage (½) RMS: One cycle calculation refreshed every half cycle; Current (½) RMS: Half-cycle calculation
4. Voltage swell, voltage dips, voltage interruption
5. Inrush current
6. Voltage waveform comparison
7. Instantaneous flicker value: As per IEC61000-4-15
8. 200 ms frequency: Calculated as 10 or 12 cycles, 40 to 70 Hz
9. 10 second frequency: Calculated as the whole-cycle time during the specified 10 second period, 40 to 70 Hz
10. Voltage waveform peak, current waveform peak
11. Voltage, current, active power, apparent power, reactive power, active energy, reactive energy, power factor, displacement power factor, voltage unbalance factor, current unbalance factor, and efficiency
12. High-order harmonic component (voltage/current): 2 to 80 kHz
13. Harmonic/harmonic phase angle (voltage/current); Harmonic power: 0 to 50 th orders
14. Harmonic voltage-current phase angle: 1 to 50 th orders
15. Total harmonic distortion factor (voltage/current)
16. Inter harmonic (voltage/current): 0.5 to 49.5 th order
17. K Factor (multiplication factor)
18. IEC flicker, Δ V10 flicker
Record Repeated on: One year, maximum recording event: 9999 x 366 days (up to 9999 events per day)
Repeated off: 35 days, maximum recording event: 9999 events
Interfaces SD/SDHC memory card, LAN (HTTP server function/FTP function), USB 2.0 (for communication)
Display 6.5" (165.1 mm) TFT color LCD (640 x 480)
Power Supply AC adapter: 100 to 240 V AC, 50/60 Hz, rated current 1.7 A
Battery pack: Continuous use: 180 minutes; charging time: Maximum 5.5 hours with AC adapter
Dimensions 11.81 x 8.31 x 2.68" (300 x 211 x 68 mm)
Weight 5.7 lbs (2.6 kg) with battery pack
Click here for complete specifications on the Hioki 3198

What's included with the Hioki 3198

  • Power Quality Analyzer
  • 8 x Voltage Cord L1000 with Alligator Clip
  • 20 x Spiral Tube
  • Color clip
  • AC Adapter Z1002
  • Strap
  • USB Cable
  • SD Memory Card 2GB Z4001
  • Battery Pack Z1003
  • Measurement Guide
  • Manual

Ask a question about Hioki PQ3198 Power Quality Analyzer

Customer Reviews for the Hioki 3198

Hioki 3198 Offers

Featuring continuous gapless recording and high accuracy, use the Power Quality Analyzer to verify power problems in accordance with the IEC61000-4-30 Class A Standard.

Features

  • CAT IV 600V - safe enough for incoming power lines
  • Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz
  • Wide dynamic range from low voltages up to 1300V (3P4W line-to-line voltage)
  • Maximum 6000V transient overvoltage up to 700kHz
  • International power quality measurement standard IEC 61000-4-30 Edition 2 Class A
  • LAN, USB and SD card interfaces
  • Optional GPS BOX for synchronizing multiple devices

Applications

  • Power quality troubleshooting in industrial and commercial electrical systems

The number of power supply problems is increasing as power systems are becoming more and more complicated - all due to the rising use of power electronics devices plus a growing installed base of large systems and distributed power supplies. The quickest way to approach these problems is to understand the situation quickly and accurately. The Power Quality Analyzer is ready to effectively solve your power supply problems.

  • EV charger and inverter testing for power quality and efficiency verification

The unit can measure all waveforms of power, harmonic, and error events simultaneously. When a problem occurs with the equipment or system on your site, the analyzer will help you detect the cause of the problem early and solve it quickly. You can depend on the PW3198 to monitor all aspects of your power supplies.

  • UPS and renewable energy monitoring for harmonics, voltage events, and power anomalies

Hioki 3198 Specifications

Measurement Line Type Single-phase two-wire
Single-phase three-wire
Three-phase three-wire or three-phase three-wire plus one extra input channel for voltage, current, power measurement (AC or DC measurement)
Ranges Voltage: 600 Vrms, 6.0000 kV peak (transient)
Current: 100 A
Power: 300 W to 3.0000 MW (determined automatically based on voltage and current range in use)
Basic Accuracy Voltage: ±0.1% of nominal voltage
Current: ±0.1% rdg, ±0.1% f.s. + current sensor accuracy
Active power: ±0.2% rdg, ±0.1% f.s. + current sensor accuracy
Measurement Items 1. Transient voltage: 2 MHz sampling
2. Frequency cycle: Calculated as one cycle, 40 to 70 Hz
3. Voltage (½) RMS: One cycle calculation refreshed every half cycle; Current (½) RMS: Half-cycle calculation
4. Voltage swell, voltage dips, voltage interruption
5. Inrush current
6. Voltage waveform comparison
7. Instantaneous flicker value: As per IEC61000-4-15
8. 200 ms frequency: Calculated as 10 or 12 cycles, 40 to 70 Hz
9. 10 second frequency: Calculated as the whole-cycle time during the specified 10 second period, 40 to 70 Hz
10. Voltage waveform peak, current waveform peak
11. Voltage, current, active power, apparent power, reactive power, active energy, reactive energy, power factor, displacement power factor, voltage unbalance factor, current unbalance factor, and efficiency
12. High-order harmonic component (voltage/current): 2 to 80 kHz
13. Harmonic/harmonic phase angle (voltage/current); Harmonic power: 0 to 50 th orders
14. Harmonic voltage-current phase angle: 1 to 50 th orders
15. Total harmonic distortion factor (voltage/current)
16. Inter harmonic (voltage/current): 0.5 to 49.5 th order
17. K Factor (multiplication factor)
18. IEC flicker, Δ V10 flicker
Record Repeated on: One year, maximum recording event: 9999 x 366 days (up to 9999 events per day)
Repeated off: 35 days, maximum recording event: 9999 events
Interfaces SD/SDHC memory card, LAN (HTTP server function/FTP function), USB 2.0 (for communication)
Display 6.5" (165.1 mm) TFT color LCD (640 x 480)
Power Supply AC adapter: 100 to 240 V AC, 50/60 Hz, rated current 1.7 A
Battery pack: Continuous use: 180 minutes; charging time: Maximum 5.5 hours with AC adapter
Dimensions 11.81 x 8.31 x 2.68" (300 x 211 x 68 mm)
Weight 5.7 lbs (2.6 kg) with battery pack
Click here for complete specifications on the Hioki 3198

What's included with the Hioki 3198

  • Power Quality Analyzer
  • 8 x Voltage Cord L1000 with Alligator Clip
  • 20 x Spiral Tube
  • Color clip
  • AC Adapter Z1002
  • Strap
  • USB Cable
  • SD Memory Card 2GB Z4001
  • Battery Pack Z1003
  • Measurement Guide
  • Manual

Ask a question about Hioki PQ3198 Power Quality Analyzer

Customer Reviews for the Hioki 3198

More Hioki Products