1.888.610.7664

sales@GlobalTestSupply.com

Customer Reviews

Veris H931 Current Monitoring Current Transducer with relay, 4 to 20 mA analog output

Model: H931

Veris H931 Current Monitoring Current Transducer with relay, 4 to 20 mA analog output-


Downloads: datasheet

Veris H931 Current Monitoring Current Transducer with relay, 4 to 20 mA analog output

Model: H931

The current monitoring transducer with relay provides accurate load trending information with a proportional 4 to 20 mA output signal and offers 3 amperage ranges for versatility. Complete with easy slide-switch selection.

The current monitoring transducer with relay provides accurate load trending information with a proportional 4 to 20 mA output signal and offers 3 amperage ranges for versatility. Complete with easy slide-switch selection.

Sale Price $110.20 USD
Regular Price $339.04 USD
Availability 2 to 3 Weeks
Quantity

Veris H931 Offers

The current monitoring transducer with relay provides accurate load trending information with a proportional 4 to 20 mA output signal and offers 3 amperage ranges for versatility. Complete with easy slide-switch selection.

Features

  • Reduces the number of installed components, which saves time and space
  • Self-gripping split-core for fast retrofit installation; no need to remove conductor
  • 1 device to install for start/stop and status; reduces installation charges
  • Power the current sensor and receive the 4 to 20 mA signal with only 2 wires; fewer wires required than with traditional 3-wire sensors
  • Factory calibrated switch-selectable ranges (30/60/120 A) for high resolution and installation ease
  • No jumpers on unit to help reduce installation error
  • Bracket can be installed in 3 different configurations for added flexibility
  • Command relay switches up to 5 A at 250 VAC
  • 5-year limited warranty

Applications

  • Load Trending
  • Motor Control
  • Positive Proof of Flow

Veris H931 Specifications

Sensor Power 30 mA (max) at 12 to 30 VDC
Insulation Class 600 VAC RMS
Frequency Range 50/60 Hz
Temperature Range 5 to 140°F (-15 to 60°C)
Humidity Range 10 to 90% RH non-condensing
Accuracy ±2% FS from 10 to 100% (selected range)
Response Time 2 seconds
Terminal Block Wire Size 24 to 14 AWG (0.2 to 2.1 mm²)
Terminal Block Torque 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)
Warranty 5 years limited
Agency Approvals UL 508 open device listing, CAT III, Pollution Degree 2, basic insulation
Click here for complete specifications on the Veris H931

What's included with the Veris H931

  • Veris H931 Current Monitoring Current Transducer with relay, 4 to 20 mA analog output

Ask a question about Veris H931 Current Monitoring Current Transducer with relay, 4 to 20 mA analog output

Customer Reviews for the Veris H931

Veris H931 Offers

The current monitoring transducer with relay provides accurate load trending information with a proportional 4 to 20 mA output signal and offers 3 amperage ranges for versatility. Complete with easy slide-switch selection.

Features

  • Reduces the number of installed components, which saves time and space
  • Self-gripping split-core for fast retrofit installation; no need to remove conductor
  • 1 device to install for start/stop and status; reduces installation charges
  • Power the current sensor and receive the 4 to 20 mA signal with only 2 wires; fewer wires required than with traditional 3-wire sensors
  • Factory calibrated switch-selectable ranges (30/60/120 A) for high resolution and installation ease
  • No jumpers on unit to help reduce installation error
  • Bracket can be installed in 3 different configurations for added flexibility
  • Command relay switches up to 5 A at 250 VAC
  • 5-year limited warranty

Applications

  • Load Trending
  • Motor Control
  • Positive Proof of Flow

Veris H931 Specifications

Sensor Power 30 mA (max) at 12 to 30 VDC
Insulation Class 600 VAC RMS
Frequency Range 50/60 Hz
Temperature Range 5 to 140°F (-15 to 60°C)
Humidity Range 10 to 90% RH non-condensing
Accuracy ±2% FS from 10 to 100% (selected range)
Response Time 2 seconds
Terminal Block Wire Size 24 to 14 AWG (0.2 to 2.1 mm²)
Terminal Block Torque 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)
Warranty 5 years limited
Agency Approvals UL 508 open device listing, CAT III, Pollution Degree 2, basic insulation
Click here for complete specifications on the Veris H931

What's included with the Veris H931

  • Veris H931 Current Monitoring Current Transducer with relay, 4 to 20 mA analog output

Ask a question about Veris H931 Current Monitoring Current Transducer with relay, 4 to 20 mA analog output