1.888.610.7664

sales@GlobalTestSupply.com

Customer Reviews

Veris H622-10 Current Transducer, 0 to 5 VDC analog output, 0 to 10 A

Model: H622-10

Veris H622-10 Current Transducer, 0 to 5 VDC analog output, 0 to 10 A-


Downloads: datasheet

Veris H622-10 Current Transducer, 0 to 5 VDC analog output, 0 to 10 A

Model: H622-10

This is a current monitoring transducer that has a self-gripping split-core for fast retrofit installation and no need to remove conductor. The current transducer has an amperage range of 0 to 10 A and provides accurate load trending information with a proportional 0 to 5 VDC output signal and monitored amperage range without jumpers.

This is a current monitoring transducer that has a self-gripping split-core for fast retrofit installation and no need to remove conductor. The current transducer has an amperage range of 0 to 10 A and provides accurate load trending information with a proportional 0 to 5 VDC output signal and monitored amperage range without jumpers.

Sale Price $42.75 USD
Regular Price $121.04 USD
Availability 2 to 3 Weeks
Quantity

Veris H622-10 Offers

This is a current monitoring transducer that has a self-gripping split-core for fast retrofit installation and no need to remove conductor. The current transducer has an amperage range of 0 to 10 A and provides accurate load trending information with a proportional 0 to 5 VDC output signal and monitored amperage range without jumpers.

Features

  • Self-powered analog current sensor simplifies installation
  • No external power required for sensor to eliminate power supplies
  • No jumpers on unit reduces installation error
  • Factory calibrated range, no field adjustment
  • Mounting bracket included
  • 100% solid state, no moving parts to fail
  • 5-year limited warranty

Applications

  • Load Trending
  • Motor Control
  • Positive Proof of Flow

Veris H622-10 Specifications

Sensor Power Induced from monitored conductor
Insulation Class 600 VAC RMS (UL), 300 VAC RMS (CE)
Frequency Range 50/60 Hz
Temperature Range 5 to 140°F (-15 to 60°C)
Humidity Range 10 to 90% RH, non-condensing
Accuracy ±2% FS from 10 to 100% (selected range)
Response Time 2 seconds
Terminal Block Maximum Wire Size 14 AWG
Terminal Block Torque (Nominal) 4 in-lbs (0.45 N-m)
Agency Approvals UL 508 open device listing CE:EN61010-1:2001-02, CAT III, deg. 2, basic insulation
Click here for complete specifications on the Veris H622-10

What's included with the Veris H622-10

  • Veris H622-10 Current Transducer, 0 to 5 VDC analog output, 0 to 10 A

Ask a question about Veris H622-10 Current Transducer, 0 to 5 VDC analog output, 0 to 10 A

Customer Reviews for the Veris H622-10

Veris H622-10 Offers

This is a current monitoring transducer that has a self-gripping split-core for fast retrofit installation and no need to remove conductor. The current transducer has an amperage range of 0 to 10 A and provides accurate load trending information with a proportional 0 to 5 VDC output signal and monitored amperage range without jumpers.

Features

  • Self-powered analog current sensor simplifies installation
  • No external power required for sensor to eliminate power supplies
  • No jumpers on unit reduces installation error
  • Factory calibrated range, no field adjustment
  • Mounting bracket included
  • 100% solid state, no moving parts to fail
  • 5-year limited warranty

Applications

  • Load Trending
  • Motor Control
  • Positive Proof of Flow

Veris H622-10 Specifications

Sensor Power Induced from monitored conductor
Insulation Class 600 VAC RMS (UL), 300 VAC RMS (CE)
Frequency Range 50/60 Hz
Temperature Range 5 to 140°F (-15 to 60°C)
Humidity Range 10 to 90% RH, non-condensing
Accuracy ±2% FS from 10 to 100% (selected range)
Response Time 2 seconds
Terminal Block Maximum Wire Size 14 AWG
Terminal Block Torque (Nominal) 4 in-lbs (0.45 N-m)
Agency Approvals UL 508 open device listing CE:EN61010-1:2001-02, CAT III, deg. 2, basic insulation
Click here for complete specifications on the Veris H622-10

What's included with the Veris H622-10

  • Veris H622-10 Current Transducer, 0 to 5 VDC analog output, 0 to 10 A

Ask a question about Veris H622-10 Current Transducer, 0 to 5 VDC analog output, 0 to 10 A

Customer Reviews for the Veris H622-10

More Veris Products