TED MTU LITE Measuring Transmitting Unit for Pro LITE

Model: MTU LITE

Designed for three-phase wye systems in small business applications where maximum amperage is 200A and maximum voltage is 277V. To be used in conjunction with the Pro LITE.

Designed for three-phase wye systems in small business applications where maximum amperage is 200A and maximum voltage is 277V. To be used in conjunction with the Pro LITE.

This product has been discontinued. Contact us for more information.


TED MTU LITE Offers

Measures the energy consumption, demand voltage, current, and power factor. It is designed for three-phase wye systems in small business applications where maximum amperage is 200A and maximum voltage is 277V. It is also ideally suited for residential occupancies with three-phase services. Data communication between MTU and ECC is via PLC.

The MTU is generally located at the main electrical panel and transmits the information collected over the building's existing electrical wiring, using state-of-the-art Power Line Carrier communications (PLC) to an ECC which receives and interprets the data. Multiple MTUs can be used to give individual measurement of panels or loads. For systems with solar, wind or other alternative generation, TED will provide the user consumption, generation and net usage.

MTU Facts

  • 'MTU' stands for "Measuring Transmitting Unit"
  • An installed MTU (in a residence) will typically have 2 CTs (current transformers) - more CTs in three-phase systems
  • A TED system requires at least one MTU to operate
  • Accurate to within +/- 1%
  • It samples energy-data at a rate of 8,000 times per second, takes the average, and transmits that data each second to the ECC (Energy Control Center)
  • It will post one measurement every one second - which is the combined measurement of the 2 CTs (generally connected to the main circuits)
  • If there is a Spyder connected to the MTU, the Spyder measurements will post as independent data
  • Data posted includes voltage, power factor, kW

TED MTU LITE Specifications

Single-phase 2-wire or 3-wire Yes
Frequency 50/60 Hz
Maximum voltage - Phase/Neutral 277V
Minimum voltage 95V
Maximum current - per phase 200A
Maximum wire size 4/0 AWG (15mm OD)
Operating temperature -40°C<TA>+50°C
Overall accuracy Better than ±2% 1-phase
±4% 3-phase
Click here for complete specifications on the TED MTU LITE

What's included with the TED MTU LITE

  • TED MTU LITE Measuring Transmitting Unit for Pro LITE
  • Customer Reviews for the TED MTU LITE

    Ask a question about TED MTU LITE Measuring Transmitting Unit for Pro LITE

    comments powered by Disqus

    TED MTU LITE Offers

    Measures the energy consumption, demand voltage, current, and power factor. It is designed for three-phase wye systems in small business applications where maximum amperage is 200A and maximum voltage is 277V. It is also ideally suited for residential occupancies with three-phase services. Data communication between MTU and ECC is via PLC.

    The MTU is generally located at the main electrical panel and transmits the information collected over the building's existing electrical wiring, using state-of-the-art Power Line Carrier communications (PLC) to an ECC which receives and interprets the data. Multiple MTUs can be used to give individual measurement of panels or loads. For systems with solar, wind or other alternative generation, TED will provide the user consumption, generation and net usage.

    MTU Facts

    • 'MTU' stands for "Measuring Transmitting Unit"
    • An installed MTU (in a residence) will typically have 2 CTs (current transformers) - more CTs in three-phase systems
    • A TED system requires at least one MTU to operate
    • Accurate to within +/- 1%
    • It samples energy-data at a rate of 8,000 times per second, takes the average, and transmits that data each second to the ECC (Energy Control Center)
    • It will post one measurement every one second - which is the combined measurement of the 2 CTs (generally connected to the main circuits)
    • If there is a Spyder connected to the MTU, the Spyder measurements will post as independent data
    • Data posted includes voltage, power factor, kW

    TED MTU LITE Specifications

    Single-phase 2-wire or 3-wire Yes
    Frequency 50/60 Hz
    Maximum voltage - Phase/Neutral 277V
    Minimum voltage 95V
    Maximum current - per phase 200A
    Maximum wire size 4/0 AWG (15mm OD)
    Operating temperature -40°C<TA>+50°C
    Overall accuracy Better than ±2% 1-phase
    ±4% 3-phase