1.888.610.7664

sales@GlobalTestSupply.com

Chat Live

Customer Reviews

Leviton 6S101-D02 Single Element Mini Meter, 1P/2W, 120V, 0.1 kWh Resolution, Mechanical Counter, 200:0.1A Rated CT Required.

Model: 6S101-D02 | UPC: 078477547762

Leviton 6S101-D02 Single Element Mini Meter, 1P/2W, 120V, 0.1 kWh Resolution, Mechanical Counter, 200:0.1A Rated CT Required.-


Downloads: datasheet manual

Leviton 6S101-D02 Single Element Mini Meter, 1P/2W, 120V, 0.1 kWh Resolution, Mechanical Counter, 200:0.1A Rated CT Required.

Model: 6S101-D02

The Leviton 6S101-D02 single element mini meter meets all measurement and verification based opportunities - including load management and LEED rating achievement. It's designed to provide a simple and effective process for accurately capturing measurements of power consumption, and is easy to specify and install for new construction and retrofits.

The Leviton 6S101-D02 single element mini meter meets all measurement and verification based opportunities - including load management and LEED rating achievement. It's designed to provide a simple and effective process for accurately capturing measurements of power consumption, and is easy to specify and install for new construction and retrofits.

This product has been discontinued. Contact us for more information.


Leviton 6S101-D02 Offers

Features

  • Measures kWh
  • Revenue-Grade: Conforms to all applicable standards of ANSI C12.1
  • Equipped standard with an Isolated Pulse Output channel for automated meter reading
  • Available in indoor flush mount enclosure
  • Available in NEMA 4X indoor/outdoor enclosure packages and Multiple Meter Units (MMUs) from 2-19 meters
  • Utilizes revenue-grade 0.3% accuracy class 0.1A secondary solid core current transformers (CTs) that conform to all applicable ANSI requirements or 1.0% accuracy split-core CTs
  • Up to three sets of CTs per phase can be paralleled per meter without the need for a meter multiplier
  • CT lead length maximum: 48"
  • "6" models UL/cUL Listed Energy Usage Monitor per CCN FTRZ; "7" models UL/cUL Recognized Energy Usage Monitoring Equipment
  • Ten year warranty

Applications

Use Mini Meters in multi-tenant residential and certain commercial industrial applications for:

  • Load profiling and benchmarking
  • AMR/BAS/BMS/EMS integration
  • Usage aggregation
  • Tenant cost allocation
  • Measurement and verification
  • Energy conservation and cost reduction
  • Green building initiatives and Government mandates

Leviton 6S101-D02 Specifications

Electrical
Input Configurations 1 Phase, 2 Wire
1 or 2 Phase, 3 Wire
Supply Voltage Range (L1 or L2 to Neutral) 102 VAC to 138 VAC
Maximum Input Power (L1 and L2) 8 VA
Maximum Rated Current 440 A primary for 400 A models
220 A primary for 200 A models
110 A primary for 100 A models
0.11 A secondary for 0.1 A secondary models
0.22 A secondary for 0.2 A secondary models
Line Frequency 50 to 60 Hz
Power Factor Range 0.5 to 1.0, Leading or Lagging
Accuracy +/- 0.5% of registration @ 1.0pf. 2 to 200 A
+/- 0.75% of registration @ 0.5pf, 2 to 200 A
Operating Temperature Range -30 to 60°C
Rated Pollution Degree 2
Rated Relative Humidity 80%
Inputs
Voltage Inputs (Wire Connections) L1: Black wire, voltage input, Line 1, 120V with respect to neutral
N: White wire, Neutral input
L2: Red wire, voltage input, Line 2, 120V with respect to neutral (7B and 5B models only)
CT Inputs CT1: X1 Current Transformer input, CT1. Colored wire of CT 1
CT1: X2 Current Transformer input, CT1. White wire of CT1
CT2: X1 Current Transformer input, CT2.Colored wire of CT2 (7B and 5B models only)
CT2: X2 Current Transformer input, CT2. White wire of CT2 (7B and 5B models only)
Outputs
10, Isolated Output (10 Wh/P, Kh = 10) Isolated Pulse Output: 5 watthours on, 5 watthours off, referenced to ISOL COM NOT TO BE USED FOR FIELD WIRING
100, Isolated Output (100 Wh/P, Kh=100) Isolated Pulse Output: 50 watthours on, 50 watthours off, referenced to ISOL COM
1000, Isolated Output (1 kWh/P, Kh=1000) Isolated pulse output: 500 watthours on, 500 watthours off, referenced to ISOL COM (not available on models with T suffix)
ISOL COM Isolated common for 10/100/1000 isolated outputs
Counter (kh = 100 or kh = 1000) For 12 VDC electro-mechanical counter
Counter (kh = 100 or kh = 1000) For 12 VDC electro-mechanical counter
+12 VDC (MMS and MMD models only) 12 VDC Output; current rating is 3 mA max.
LED Indicators
Power LED (Green) Illuminates when the meter is supplied with proper voltage
Load LED (Green) 50% duty cycle (at constant load) LED to verify proper meter function when connected to a load. At 200 watts, LED will illuminate for 1.5 minutes, then turn off for 1.5 minutes; with no load, LED will remain on or off
Reverse Phase LED (Red) Illuminates when a problem with meter phasing exists. With no load, LED may be on or off. See CT installation section for instructions.
LCD Display Optional LCD display that shows total kWh
Click here for complete specifications on the Leviton 6S101-D02

What's included with the Leviton 6S101-D02

  • Leviton 6S101-D02 Single Element Mini Meter, 1P/2W, 120V, 0.1 kWh Resolution, Mechanical Counter, 200:0.1A Rated CT Required.
  • Submetering How To Step 1 - Evaluate Facility

    Submetering How To Step 2 - Energy Information Plan

    Submetering How To Step 3 - Install

    Customer Reviews for the Leviton 6S101-D02

    Ask a question about Leviton 6S101-D02 Single Element Mini Meter, 1P/2W, 120V, 0.1 kWh Resolution, Mechanical Counter, 200:0.1A Rated CT Required.

    comments powered by Disqus

    Leviton 6S101-D02 Offers

    Features

    • Measures kWh
    • Revenue-Grade: Conforms to all applicable standards of ANSI C12.1
    • Equipped standard with an Isolated Pulse Output channel for automated meter reading
    • Available in indoor flush mount enclosure
    • Available in NEMA 4X indoor/outdoor enclosure packages and Multiple Meter Units (MMUs) from 2-19 meters
    • Utilizes revenue-grade 0.3% accuracy class 0.1A secondary solid core current transformers (CTs) that conform to all applicable ANSI requirements or 1.0% accuracy split-core CTs
    • Up to three sets of CTs per phase can be paralleled per meter without the need for a meter multiplier
    • CT lead length maximum: 48"
    • "6" models UL/cUL Listed Energy Usage Monitor per CCN FTRZ; "7" models UL/cUL Recognized Energy Usage Monitoring Equipment
    • Ten year warranty

    Applications

    Use Mini Meters in multi-tenant residential and certain commercial industrial applications for:

    • Load profiling and benchmarking
    • AMR/BAS/BMS/EMS integration
    • Usage aggregation
    • Tenant cost allocation
    • Measurement and verification
    • Energy conservation and cost reduction
    • Green building initiatives and Government mandates

    Leviton 6S101-D02 Specifications

    Electrical
    Input Configurations 1 Phase, 2 Wire
    1 or 2 Phase, 3 Wire
    Supply Voltage Range (L1 or L2 to Neutral) 102 VAC to 138 VAC
    Maximum Input Power (L1 and L2) 8 VA
    Maximum Rated Current 440 A primary for 400 A models
    220 A primary for 200 A models
    110 A primary for 100 A models
    0.11 A secondary for 0.1 A secondary models
    0.22 A secondary for 0.2 A secondary models
    Line Frequency 50 to 60 Hz
    Power Factor Range 0.5 to 1.0, Leading or Lagging
    Accuracy +/- 0.5% of registration @ 1.0pf. 2 to 200 A
    +/- 0.75% of registration @ 0.5pf, 2 to 200 A
    Operating Temperature Range -30 to 60°C
    Rated Pollution Degree 2
    Rated Relative Humidity 80%
    Inputs
    Voltage Inputs (Wire Connections) L1: Black wire, voltage input, Line 1, 120V with respect to neutral
    N: White wire, Neutral input
    L2: Red wire, voltage input, Line 2, 120V with respect to neutral (7B and 5B models only)
    CT Inputs CT1: X1 Current Transformer input, CT1. Colored wire of CT 1
    CT1: X2 Current Transformer input, CT1. White wire of CT1
    CT2: X1 Current Transformer input, CT2.Colored wire of CT2 (7B and 5B models only)
    CT2: X2 Current Transformer input, CT2. White wire of CT2 (7B and 5B models only)
    Outputs
    10, Isolated Output (10 Wh/P, Kh = 10) Isolated Pulse Output: 5 watthours on, 5 watthours off, referenced to ISOL COM NOT TO BE USED FOR FIELD WIRING
    100, Isolated Output (100 Wh/P, Kh=100) Isolated Pulse Output: 50 watthours on, 50 watthours off, referenced to ISOL COM
    1000, Isolated Output (1 kWh/P, Kh=1000) Isolated pulse output: 500 watthours on, 500 watthours off, referenced to ISOL COM (not available on models with T suffix)
    ISOL COM Isolated common for 10/100/1000 isolated outputs
    Counter (kh = 100 or kh = 1000) For 12 VDC electro-mechanical counter
    Counter (kh = 100 or kh = 1000) For 12 VDC electro-mechanical counter
    +12 VDC (MMS and MMD models only) 12 VDC Output; current rating is 3 mA max.
    LED Indicators
    Power LED (Green) Illuminates when the meter is supplied with proper voltage
    Load LED (Green) 50% duty cycle (at constant load) LED to verify proper meter function when connected to a load. At 200 watts, LED will illuminate for 1.5 minutes, then turn off for 1.5 minutes; with no load, LED will remain on or off
    Reverse Phase LED (Red) Illuminates when a problem with meter phasing exists. With no load, LED may be on or off. See CT installation section for instructions.
    LCD Display Optional LCD display that shows total kWh
    Click here for complete specifications on the Leviton 6S101-D02

    What's included with the Leviton 6S101-D02

  • Leviton 6S101-D02 Single Element Mini Meter, 1P/2W, 120V, 0.1 kWh Resolution, Mechanical Counter, 200:0.1A Rated CT Required.
  • Submetering How To Step 1 - Evaluate Facility

    Submetering How To Step 2 - Energy Information Plan

    Submetering How To Step 3 - Install

    Ask a question about Leviton 6S101-D02 Single Element Mini Meter, 1P/2W, 120V, 0.1 kWh Resolution, Mechanical Counter, 200:0.1A Rated CT Required.

    Customer Reviews for the Leviton 6S101-D02

    More Leviton Products