1.888.610.7664

sales@GlobalTestSupply.com

Customer Reviews

Kyoritsu 6050 Combi Tester LOOP plus RCD

Model: 6050 | Order No: KEW6050

Kyoritsu 6050 Combi Tester LOOP plus RCD-

Kyoritsu 6050 Combi Tester LOOP plus RCD

Model: 6050 | Order No: KEW6050

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Portable Power Quality Analyzers category for similar products.

Or let's do a search and help you find what you need:


Kyoritsu 6050 Combi Tester LOOP plus RCD

The Kyoritsu 6050 Combitester provides the ultimate in Microprocessor technology offering Loop and RCD tests with a comprehensive memory and downloading test results.

  • LOOP Impedance 200/2000Ω range measurement is carried out using a test current of 15mA. This current will not trip RCD’s rated at 30mA or greater.
  • High resolution for low Loop Impedance (resolution of 0.01Ω) on 20Ω range.
  • Direct reading of Prospective Short Circuit Current (PSC) and earth fault current.
  • RCD tests at 0 and 180 degree phase angle switch permit quick tests and consistent readings.
  • Test of a large kind of RCD's Standard, Selective, AC and A (DC sensitive breakers).
  • Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
  • RCD Ramp test in order to indicate the actual tripping current of RCD.
  • Contact Voltage Reading (UC). with two selectable contact voltage limits(50 and 25V).
  • Visual indication of correct wiring status and automatic lock-out if test resistors overheats.
  • Designed to IEC 61010-1, IEC 61557 and high protection degree IP54.
  • The stored data can be transferred to PC via Optical Adapter Model 8212-RS232C and 8212-USB.

Specifications:

Loop Impedance Ranges(Z reading) 20/200/2000Ω Loop Impedance Ranges without tripping RCDs 200 and 2000Ω with 15mA of test current Max test current on Loop ranges 3A (20Ω) / 15mA (200 and 2000Ω) PSC / Earth Fault Current Ranges 200/2000A/20kA RCD Test AC Type(Standard and Selective)

  • × 1/2 10, 30, 100, 300, 500, 1000mA
  • × 1 10, 30, 100, 300, 500, 1000mA
  • × 5 10, 30, 100mA
  • Auto Ramp 10, 30, 100, 300, 500mA

RCD Test A Type(Standard and Selective) 10, 30, 100, 300, 500mA RCD Test Currents multipliers

  • × 1/2, × 1, × 5
  • (max 1000mA type AC)
  • (max 500mA type A)

RCD Test Time Duration

  • 1000ms: × 1/2, × 1, DC
  • 200ms: × 5, DC (500mA), and × 1 (1000mA)

RCD Ramp Test From 20% to 110% of IΔn (AC type) Contact Voltage Block (RCD) 50V and 25V Contact Voltage Reading (RCD) 100.0V Phase and Earth(2 wires only) measurements

  • RCD (without DC)
  • LOOP

Working Voltage for Loop Tests

  • 20Ω: 230V+10%-15%
  • 200/2000Ω: 230V+10%-15% and 400V+10%-15%

Working Voltage for RCD Tests 230V+10%-15% Voltage Test

  • 100 ~ 260V
  • (LOOP 200/2000Ω, PSC 200A:100 ~ 440V)

Memory 300 memory locations PC Software, Connection Cable optional with 8212-USB, 8212-RS232C Safety Standards IEC 61010-1 CAT.III 300V, IEC 61557 Power Source 8 × 1.5V R6P(AA) Dimensions 186(L) × 167(W) × 89(D)mm Weight 980g

Accessories Included:

  • Molded Plug Test Lead 7125-EU
  • Pouch for Test Leads
  • Instruction Manual
  • Shoulder Strap
  • Batteries

Optional Accessories:

  • 7121B (Simplified measurement probe)
  • 8212-RS232C
  • (RS232C adaptor with KEW Report (Software))
  • 8212-USB
  • (USB adaptor with KEW Report (Software))

What's included with the Kyoritsu 6050

  • Kyoritsu 6050 Combi Tester LOOP plus RCD

Ask a question about Kyoritsu 6050 Combi Tester LOOP plus RCD

Customer Reviews for the Kyoritsu 6050

Kyoritsu 6050 Combi Tester LOOP plus RCD

The Kyoritsu 6050 Combitester provides the ultimate in Microprocessor technology offering Loop and RCD tests with a comprehensive memory and downloading test results.

  • LOOP Impedance 200/2000Ω range measurement is carried out using a test current of 15mA. This current will not trip RCD’s rated at 30mA or greater.
  • High resolution for low Loop Impedance (resolution of 0.01Ω) on 20Ω range.
  • Direct reading of Prospective Short Circuit Current (PSC) and earth fault current.
  • RCD tests at 0 and 180 degree phase angle switch permit quick tests and consistent readings.
  • Test of a large kind of RCD's Standard, Selective, AC and A (DC sensitive breakers).
  • Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings.
  • RCD Ramp test in order to indicate the actual tripping current of RCD.
  • Contact Voltage Reading (UC). with two selectable contact voltage limits(50 and 25V).
  • Visual indication of correct wiring status and automatic lock-out if test resistors overheats.
  • Designed to IEC 61010-1, IEC 61557 and high protection degree IP54.
  • The stored data can be transferred to PC via Optical Adapter Model 8212-RS232C and 8212-USB.

Specifications:

Loop Impedance Ranges(Z reading) 20/200/2000Ω Loop Impedance Ranges without tripping RCDs 200 and 2000Ω with 15mA of test current Max test current on Loop ranges 3A (20Ω) / 15mA (200 and 2000Ω) PSC / Earth Fault Current Ranges 200/2000A/20kA RCD Test AC Type(Standard and Selective)

  • × 1/2 10, 30, 100, 300, 500, 1000mA
  • × 1 10, 30, 100, 300, 500, 1000mA
  • × 5 10, 30, 100mA
  • Auto Ramp 10, 30, 100, 300, 500mA

RCD Test A Type(Standard and Selective) 10, 30, 100, 300, 500mA RCD Test Currents multipliers

  • × 1/2, × 1, × 5
  • (max 1000mA type AC)
  • (max 500mA type A)

RCD Test Time Duration

  • 1000ms: × 1/2, × 1, DC
  • 200ms: × 5, DC (500mA), and × 1 (1000mA)

RCD Ramp Test From 20% to 110% of IΔn (AC type) Contact Voltage Block (RCD) 50V and 25V Contact Voltage Reading (RCD) 100.0V Phase and Earth(2 wires only) measurements

  • RCD (without DC)
  • LOOP

Working Voltage for Loop Tests

  • 20Ω: 230V+10%-15%
  • 200/2000Ω: 230V+10%-15% and 400V+10%-15%

Working Voltage for RCD Tests 230V+10%-15% Voltage Test

  • 100 ~ 260V
  • (LOOP 200/2000Ω, PSC 200A:100 ~ 440V)

Memory 300 memory locations PC Software, Connection Cable optional with 8212-USB, 8212-RS232C Safety Standards IEC 61010-1 CAT.III 300V, IEC 61557 Power Source 8 × 1.5V R6P(AA) Dimensions 186(L) × 167(W) × 89(D)mm Weight 980g

Accessories Included:

  • Molded Plug Test Lead 7125-EU
  • Pouch for Test Leads
  • Instruction Manual
  • Shoulder Strap
  • Batteries

Optional Accessories:

  • 7121B (Simplified measurement probe)
  • 8212-RS232C
  • (RS232C adaptor with KEW Report (Software))
  • 8212-USB
  • (USB adaptor with KEW Report (Software))

What's included with the Kyoritsu 6050

  • Kyoritsu 6050 Combi Tester LOOP plus RCD

Ask a question about Kyoritsu 6050 Combi Tester LOOP plus RCD

Customer Reviews for the Kyoritsu 6050

More Kyoritsu Products