Compact and installer-friendly, this protective relay Rogowski coil integrator is compatible with any protection relay or power meter with a 1 A nominal input. In addition, this integrator features five field-configurable CT ratios to switch between high and low amperage loads effortlessly.
Compact and installer-friendly, this protective relay Rogowski coil integrator is compatible with any protection relay or power meter with a 1 A nominal input. In addition, this integrator features five field-configurable CT ratios to switch between high and low amperage loads effortlessly.
Features
Applications
Rated Current | |
Range | Current: 0.25 to 100,000 A Sensing: 50, 200, 500, 2000, and 5000 A user selectable |
Integrator's Current Range Settings | Primary input (Arms): 50 200 500 2000 5000 Sensing range: 0.25 to 1000 1 to 4000 2.5 to 10000 10 to 40000 25 to 10,0000 Output: 1 A at 50 A 1 A at 200 A 1 A at 500 A 1 A at 2000 A 1 A at 5000 A Relay class output: 20 A at 1 kA 20 A at 4 kA 20 A at 10 kA 20 A at 40 kA 20 A at 100 kA CT ratio: 50:1 200:1 500:1 2000:1 5000:1 |
Integrator | Output: 0 to 1 A Accuracy: 1% at 1 A, 5% at 20 A |
Phase Maximum Error | 1 degree |
Class | 5P20 (IEC 61869-2) |
Thermal Current | Continuous: 150% (1.5 A) Short-time: 20 A Short-time maximum duration: 4 seconds |
Settling Time to Full Scale | <100 μs |
Electrical | |
Measurement Channels | 1 |
Frequency Range | 50⁄60 Hz |
Power Supply | 100 to 240 V AC |
Burden | 0.25 Ω |
General Specifications | |
Input/Output Wire Connection | 14 to 30 AWG |
Operating Temperature | Temperature: -13 to 158°F (-25 to 70°C) Humidity: Non-condensing, 0 to 95% RH |
Integrator Enclosure Material | ABS, UL 94V-0 |
Mounting | DIN TS-35/7.5 or 15 (DIN 43880) or Panel |
Overload Protection | Thermal |
Certifications | CE, UL Listed (E359521), RoHS |
Dimensions | 7.83 x 4.93 x 4.47" (199 x 125.2 x 113.5 mm) |
Weight | 0.8 lbs (362.9 g) |
Click on a category to view a selection of compatible accessories with the Accuenergy RIK 1AR Protective Relay Rogowski Coil Integrator, 0.25 to 100,000 A, 50/60 Hz.
Rated Current | |
Range | Current: 0.25 to 100,000 A Sensing: 50, 200, 500, 2000, and 5000 A user selectable |
Integrator's Current Range Settings | Primary input (Arms): 50 200 500 2000 5000 Sensing range: 0.25 to 1000 1 to 4000 2.5 to 10000 10 to 40000 25 to 10,0000 Output: 1 A at 50 A 1 A at 200 A 1 A at 500 A 1 A at 2000 A 1 A at 5000 A Relay class output: 20 A at 1 kA 20 A at 4 kA 20 A at 10 kA 20 A at 40 kA 20 A at 100 kA CT ratio: 50:1 200:1 500:1 2000:1 5000:1 |
Integrator | Output: 0 to 1 A Accuracy: 1% at 1 A, 5% at 20 A |
Phase Maximum Error | 1 degree |
Class | 5P20 (IEC 61869-2) |
Thermal Current | Continuous: 150% (1.5 A) Short-time: 20 A Short-time maximum duration: 4 seconds |
Settling Time to Full Scale | <100 μs |
Electrical | |
Measurement Channels | 1 |
Frequency Range | 50⁄60 Hz |
Power Supply | 100 to 240 V AC |
Burden | 0.25 Ω |
General Specifications | |
Input/Output Wire Connection | 14 to 30 AWG |
Operating Temperature | Temperature: -13 to 158°F (-25 to 70°C) Humidity: Non-condensing, 0 to 95% RH |
Integrator Enclosure Material | ABS, UL 94V-0 |
Mounting | DIN TS-35/7.5 or 15 (DIN 43880) or Panel |
Overload Protection | Thermal |
Certifications | CE, UL Listed (E359521), RoHS |
Dimensions | 7.83 x 4.93 x 4.47" (199 x 125.2 x 113.5 mm) |
Weight | 0.8 lbs (362.9 g) |
Click on a category to view a selection of compatible accessories with the Accuenergy RIK 1AR Protective Relay Rogowski Coil Integrator, 0.25 to 100,000 A, 50/60 Hz.