PowerPad Model 8335 with 4 SR193 (1200A).
PowerPad Model 8335 with 4 SR193 (1200A).
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
| Sampling Frequency | 256 samples per cycle |
| Data Storage | 2GB SD Card |
| Voltage (TRMS) | Phase-to-Phase: 1000V; Phase-to-Neutral: 1000V |
| Current (TRMS) | MN Clamp: 0 to 6A/120A or 0 to 240A MR Clamp: 0 to 1200AAC, 0 to 1400ADC SR Clamp: 0 to 1200A AmpFlex: 0 to 6500A¹ |
| MEASUREMENT | RANGE |
| Single-Phase RMS Voltages | 15 to 1000V |
| Phase-to-Phase RMS Voltages | 15 to 1000V |
| Single-Phase Peak Voltages | 15 to 1414V |
| Phase-to-Phase Peak Voltages | 15 to 1414V |
| Frequency (Hz) | 40 to 69Hz |
| DC Voltage Component | 15 to 1000V |
| Current Probes MN Clamp SR Clamp AmpFlex Probe |
0 to 240A 0 to 1200A 10 to 6500A |
| Active (Real) Power (kW) | 0 to 9999kW |
| Reactive Power (kVAR) | 0 to 9999kVAR |
| Apparent Power (kVA) | 0 to 9999kVA |
| Power Factor (PF & DPF) | -1.000 to 1.000 |
| Active Energy (kWh) | 0 to 9999MWh |
| Reactive Energy (kVARh) | 0 to 9999MVARh |
| Apparent Energy (kVAh) | 0 to 9999MVAh |
| Unbalance (V & A) | 0 to 100% |
| Phase Angle (V-A, A-A, V-V)) | -179° to +180° |
| Harmonics (1st to 50th) F = 40 to 69Hz (V >e; 50V, A > Inom/100) |
0 to 999% |
| Total Harmonic Distortion (V & A) | 0 to 999% |
| K-factor (Akf) | 1 to 99.99 |
| Flicker (PST) | 0.00 to 9.99 |
| Power Source | 9.6V NiMH rechargeable battery pack AC supply: 110/230VAC ±20% (50/60Hz) |
| Battery Life | ≤8 hrs with display on; ≤35 hrs with display off (record mode) |
| Operating Temperature | 32° to 122°F (0° to 50°C) |
| Storage Temperature | -4° to +122°F (-20° to +50°C) |
| Display 1/4 VGA | (320 x 240) color LCD |
| Dimensions | 9.5 x 7 x 2" (240 x 180 x 55mm) |
| Weight | 4.6 lbs (2.1kg) |
| Safety Rating | EN 61010-1, 600V Cat. III, Pollution Degree 2 |
| Double Insulation | Yes |
| CE Mark | Yes |