Flexible 36" 6000A AC current probe with BNC terminated lead.
Flexible 36" 6000A AC current probe with BNC terminated lead.
The Fluke i6000s Flex is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
| Current Ranges | 60 A / 600 A / 6000 A ACRMS | ||
| Output Sensitivity (AC coupled) | 50 mV /5mV / 0.5mV per A | ||
| Load Impedance | 100 kOhm minimum | ||
| Accuracy (at +25°C) | ±1% of range (45 - 65 Hz) | ||
| Linearity (10% to 100% of range) | ±0.2% of reading | ||
| Noise | 8mV ACRMS (60 A) 2 mV ACRMS (600/6000A) | ||
| Frequency Range | 10 Hz to 50 kHz (- 3 dB) | ||
| Phase Error | < ±1° (45 - 65Hz), ±10° (at 20 kHz) </td> | ||
| Position Sensitivity (with cable > 25mm from the coupling) | ±2% of range | ||
| External field (with cable > 200mm from the head) | ±1% of range | ||
| Power Supply | 2 x AA MN 1500 LR6 alkaline 400 Hours, low battery indicator or dedicated ext power supply | ||
| Temperature Coefficient | ±0.08% of reading per C | ||
| Working Voltage (see Safety Standards section) | 600 V ACRMS or DC | ||
| Head Cable length-(double insulated) |
|
||
| 610mm (24") I6000s Flex-24 915mm (36") I6000s Flex-36 |
|||
| Head Cable Diameter |
|
||
| 14.3 mm | |||
| Head Bend Radius |
|
||
| 38.1 mm | |||
| Cable length (head to electronics) |
|
||
| 2 meters | |||
| Output Connection |
|
||
| 0.5 m cable terminated with safety BNC connector Supplied with 4mm safety plug adaptor |
|||
| Operating Temperature Range |
|
||
| -20 to +90°C (head) -20 to +85°C (electronics) |
|||
| Storage Temperature Range |
|
||
| -40 to +105°C (head) -20 to +85°C (electronics) |
|||
| Operating Humidity |
|
||
| 15% to 85% (non condensing) | |||
| Weight |
|
||
| 180 g (head), 190 g (electronics) | |||
| BS EN 61010 |
|
||
| 1.4312500000000001 | |||
| BS EN 61010 |
|
||
| 2-032: 2002 | |||
| BS EN 61010 |
|
||
| 031: 2002 | |||
| 600VRMS, Category III, Pollution Degree 2 | |||
| Note |
|
||
| Use of the probe on uninsulated conductors is limited to 600 V ACRMS or DC and frequencies below 1 kHz. | |||
| EMC Standards |
|
||
| BS EN 61326 | 1998 +A1, A2, & A3 |
Click on a category to view a selection of compatible accessories with the Fluke i6000s Flex-36 AC Current Probe.
| Current Ranges | 60 A / 600 A / 6000 A ACRMS | ||
| Output Sensitivity (AC coupled) | 50 mV /5mV / 0.5mV per A | ||
| Load Impedance | 100 kOhm minimum | ||
| Accuracy (at +25°C) | ±1% of range (45 - 65 Hz) | ||
| Linearity (10% to 100% of range) | ±0.2% of reading | ||
| Noise | 8mV ACRMS (60 A) 2 mV ACRMS (600/6000A) | ||
| Frequency Range | 10 Hz to 50 kHz (- 3 dB) | ||
| Phase Error | < ±1° (45 - 65Hz), ±10° (at 20 kHz) </td> | ||
| Position Sensitivity (with cable > 25mm from the coupling) | ±2% of range | ||
| External field (with cable > 200mm from the head) | ±1% of range | ||
| Power Supply | 2 x AA MN 1500 LR6 alkaline 400 Hours, low battery indicator or dedicated ext power supply | ||
| Temperature Coefficient | ±0.08% of reading per C | ||
| Working Voltage (see Safety Standards section) | 600 V ACRMS or DC | ||
| Head Cable length-(double insulated) |
|
||
| 610mm (24") I6000s Flex-24 915mm (36") I6000s Flex-36 |
|||
| Head Cable Diameter |
|
||
| 14.3 mm | |||
| Head Bend Radius |
|
||
| 38.1 mm | |||
| Cable length (head to electronics) |
|
||
| 2 meters | |||
| Output Connection |
|
||
| 0.5 m cable terminated with safety BNC connector Supplied with 4mm safety plug adaptor |
|||
| Operating Temperature Range |
|
||
| -20 to +90°C (head) -20 to +85°C (electronics) |
|||
| Storage Temperature Range |
|
||
| -40 to +105°C (head) -20 to +85°C (electronics) |
|||
| Operating Humidity |
|
||
| 15% to 85% (non condensing) | |||
| Weight |
|
||
| 180 g (head), 190 g (electronics) | |||
| BS EN 61010 |
|
||
| 1.4312500000000001 | |||
| BS EN 61010 |
|
||
| 2-032: 2002 | |||
| BS EN 61010 |
|
||
| 031: 2002 | |||
| 600VRMS, Category III, Pollution Degree 2 | |||
| Note |
|
||
| Use of the probe on uninsulated conductors is limited to 600 V ACRMS or DC and frequencies below 1 kHz. | |||
| EMC Standards |
|
||
| BS EN 61326 | 1998 +A1, A2, & A3 |
Click on a category to view a selection of compatible accessories with the Fluke i6000s Flex-36 AC Current Probe.