1.888.610.7664

sales@GlobalTestSupply.com

Customer Reviews

Dent CT-R36-1310-U Current Transformer

Model: CT-R36-1310-U

Dent CT-R36-1310-U Current Transformer-


Downloads: datasheet

Dent CT-R36-1310-U Current Transformer

Model: CT-R36-1310-U

36" Rocoil Flexible Current Transformers. 5 to 5000A, Unterminated.

36" Rocoil Flexible Current Transformers. 5 to 5000A, Unterminated.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Dent CTRCFX36L4000A3MSTV1 RoCoil Flexible Current Transformer, Rogowski coil, 36", 118" leads-

Dent CTRCFX36L4000A3MSTV1 RoCoil Flexible Current Transformer, Rogowski coil, 36", 118" leads

Model: CTRCFX36L4000A3MSTV1

The RoCoil flexible current transformers have been designed for accurate, non-intrusive measurement of AC current over a wide dynamic range, where conventional rigid core sensors are unsuitable> This model has a length of 36" (90 cm) with 118" (3 m) leads.

The replacement product is only available on our affiliate GlobalTestSupply.com website. Don't worry your cart and information will be brought over.


Not what you're looking for? Let’s do a search and help you find what you need.


DENT RoCoil™ Flexible Current Transformers

TheDENT RoCoil™Current Transformers have been designed for accurate non?intrusivemeasurement of AC current, pulsed DC or distorted waveforms. Thistype ofsensormay be used to measure AC current over a wide dynamic range and from40Hz to 5 kHz.Note: The RoCoil™may require use ofintegrator/ ampli?er. See also RoCoil mV™.

RoCoil™ Dimensions

The Dimensions for RoCoil CTs
Dimensions R16
40 cm (16")
R24
60 cm (24")
R36
90 cm (36")
R72
183cm (72")
A - Window Size 13 cm(5") 19 cm(7") 26 cm(10") 56 cm(22")
B - Transformer Coil O.D. 15 cm(6") 21 cm(8") 29 cm(11") 58 cm(23")
C - Transformer Length 40 cm(16") 60 cm(24") 90 cm(36") 180 cm(72")
D - Locking ConnectorO.D. 3.6 cm(1.4")
E - Transformer Coil Diameter 1.5 cm(0.6")
F - Wire Lead Total Length 2m(80")

Key Specifications

Four Lengths 40cm(16"),60cm(24"),
90cm(36"), 183cm(72")
Window Size 13cm(5"),19cm(7"),
26cm(10"), 58cm(23")
Output Signal(di/dt) 131mVAC/1000A @ 60Hz
110mVAC/1000A @ 50Hz
Current Range 5 - 5000AAC
Accuracy < 1%

Electrical

All accuraciesspecified at 20°C (±2°C)withRoCoil™centered on conductor.

Output Signal 131mV/1000A@ 60Hz
110mV/1000A@ 50Hz
Wire Colors White = (+) positve
Brown = (?) negatve
Bare wire = shield
Phasing Arrow Points Towards Load
Phase Shift < 1° at 50/60Hz
Frequency Range 40Hzto 5 kHz
Useful Current Range 5 - 5000A AC*
Linearity ± 0.2%
Conductor Position Sensitivity ± 2%maximum
In?uence of External Field ± 1.5%maximum
Temperature Sensi?vity 0.07% per°C

Mechanical

Coil Materials Blue thermoplas?c rubber, ?ame retardantUL 94 V?0 rated
Coupling Materials PolypropyleneUL 94 V?0 rated
Shielding 85% transducer, 100% output lead
Working Temp ?20 °C to +80 °C (?4°to +176 °F)

Safety

Working Voltage 1000 Vrmsmaximum
Dielectric Strength 7400 VAC around coil
1000 VAC rated leads
Cert?cations Conforms to UL STD61010?1
Certi?ed to CAN/CSA STDC22.2
No. 61010

What's included with the Dent CT-R36-1310-U

  • Dent CT-R36-1310-U Current Transformer

Ask a question about Dent CT-R36-1310-U Current Transformer

Customer Reviews for the Dent CT-R36-1310-U

DENT RoCoil™ Flexible Current Transformers

TheDENT RoCoil™Current Transformers have been designed for accurate non?intrusivemeasurement of AC current, pulsed DC or distorted waveforms. Thistype ofsensormay be used to measure AC current over a wide dynamic range and from40Hz to 5 kHz.Note: The RoCoil™may require use ofintegrator/ ampli?er. See also RoCoil mV™.

RoCoil™ Dimensions

The Dimensions for RoCoil CTs
Dimensions R16
40 cm (16")
R24
60 cm (24")
R36
90 cm (36")
R72
183cm (72")
A - Window Size 13 cm(5") 19 cm(7") 26 cm(10") 56 cm(22")
B - Transformer Coil O.D. 15 cm(6") 21 cm(8") 29 cm(11") 58 cm(23")
C - Transformer Length 40 cm(16") 60 cm(24") 90 cm(36") 180 cm(72")
D - Locking ConnectorO.D. 3.6 cm(1.4")
E - Transformer Coil Diameter 1.5 cm(0.6")
F - Wire Lead Total Length 2m(80")

Key Specifications

Four Lengths 40cm(16"),60cm(24"),
90cm(36"), 183cm(72")
Window Size 13cm(5"),19cm(7"),
26cm(10"), 58cm(23")
Output Signal(di/dt) 131mVAC/1000A @ 60Hz
110mVAC/1000A @ 50Hz
Current Range 5 - 5000AAC
Accuracy < 1%

Electrical

All accuraciesspecified at 20°C (±2°C)withRoCoil™centered on conductor.

Output Signal 131mV/1000A@ 60Hz
110mV/1000A@ 50Hz
Wire Colors White = (+) positve
Brown = (?) negatve
Bare wire = shield
Phasing Arrow Points Towards Load
Phase Shift < 1° at 50/60Hz
Frequency Range 40Hzto 5 kHz
Useful Current Range 5 - 5000A AC*
Linearity ± 0.2%
Conductor Position Sensitivity ± 2%maximum
In?uence of External Field ± 1.5%maximum
Temperature Sensi?vity 0.07% per°C

Mechanical

Coil Materials Blue thermoplas?c rubber, ?ame retardantUL 94 V?0 rated
Coupling Materials PolypropyleneUL 94 V?0 rated
Shielding 85% transducer, 100% output lead
Working Temp ?20 °C to +80 °C (?4°to +176 °F)

Safety

Working Voltage 1000 Vrmsmaximum
Dielectric Strength 7400 VAC around coil
1000 VAC rated leads
Cert?cations Conforms to UL STD61010?1
Certi?ed to CAN/CSA STDC22.2
No. 61010

What's included with the Dent CT-R36-1310-U

  • Dent CT-R36-1310-U Current Transformer

Ask a question about Dent CT-R36-1310-U Current Transformer

Customer Reviews for the Dent CT-R36-1310-U

More Dent Products