Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 2.0" and offers a 1000A amp rating.

Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 2.0" and offers a 1000A amp rating.

Your Price $80.00 USD
Availability 1 to 2 Weeks
Quantity

Add In-House Traceable Calibration to your CT-SCL-1000-U

Add In-House Traceable Calibration to your CT-SCL-1000-U


Dent CT-SCL-1000-U Offers

The low-cost solution for permanent or long-term studies. The split core design means no de-energizing or wire disconnection required.

Opening "Split-Core" Current Transformer (SCT) provides linear output voltage that is directly proportional to the input current. This current transformer is easily and safely installed over existing electrical power lines without disconnecting the lines or interrupting service.

DENT's energy monitoring components are used for a variety of applications including building automation, tenant submetering, performance verification, energy management and new technology assessment.

Dent CT-SCL-1000-U Specifications

Key Specifications
Window Size 2.0" (5.1 cm)
Current Range 20 to 1300A AC
Output 333 mV at rated current
Ratio Error <1% at rated current (typical)
Phase Error <2° at rated current (typical)
Electrical
Output 333 mV at rated current
Wire Polarity White = Hi, positive (+)
Black = Low, negative (-)
Frequency Range 50 to 400 Hz
Mechanical
Case Material Epoxy encapsulated housing
Leads 2.7 m (8'), twisted pair, 20 AWG
Operating Temperature -4 to 131°F (-20 to 55°C)

What's included with the Dent CT-SCL-1000-U

  • Dent CT-SCL-1000-U Large Split Core Current Transformer, 1000A
  • Customer Reviews for the Dent CT-SCL-1000-U

    Ask a question about Dent CT-SCL-1000-U Large Split Core Current Transformer, 1000A

    comments powered by Disqus

    Dent CT-SCL-1000-U Offers

    The low-cost solution for permanent or long-term studies. The split core design means no de-energizing or wire disconnection required.

    Opening "Split-Core" Current Transformer (SCT) provides linear output voltage that is directly proportional to the input current. This current transformer is easily and safely installed over existing electrical power lines without disconnecting the lines or interrupting service.

    DENT's energy monitoring components are used for a variety of applications including building automation, tenant submetering, performance verification, energy management and new technology assessment.

    Dent CT-SCL-1000-U Specifications

    Key Specifications
    Window Size 2.0" (5.1 cm)
    Current Range 20 to 1300A AC
    Output 333 mV at rated current
    Ratio Error <1% at rated current (typical)
    Phase Error <2° at rated current (typical)
    Electrical
    Output 333 mV at rated current
    Wire Polarity White = Hi, positive (+)
    Black = Low, negative (-)
    Frequency Range 50 to 400 Hz
    Mechanical
    Case Material Epoxy encapsulated housing
    Leads 2.7 m (8'), twisted pair, 20 AWG
    Operating Temperature -4 to 131°F (-20 to 55°C)