1.888.610.7664

sales@GlobalTestSupply.com

Customer Reviews

TED PRO 2000A KIT Commercial Three-Phase Energy Monitoring System with Rogowski Coils, 2000A

Model: PRO 2000 | Order No: TED PRO 2000A KIT

TED PRO 2000A KIT Commercial Three-Phase Energy Monitoring System with Rogowski Coils, 2000A-


Downloads: datasheet manual

TED PRO 2000A KIT Commercial Three-Phase Energy Monitoring System with Rogowski Coils, 2000A

Model: PRO 2000 | Order No: TED PRO 2000A KIT

Designed for use in commercial or small industrial facilities, and is suitable for any three-phase system up to 2000A. View energy data on a computer or over the Internet. Colored LEDs alert for rate-tier changes, high demand, cost, or other defined parameters.

Designed for use in commercial or small industrial facilities, and is suitable for any three-phase system up to 2000A. View energy data on a computer or over the Internet. Colored LEDs alert for rate-tier changes, high demand, cost, or other defined parameters.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


TED PRO 2000A KIT Offers

Features

  • Designed for use in commercial or small industrial complexes on three-phase electrical systems up to 2000A
  • Allows you to monitor and manage energy usage
  • Energy use and alerts can be presented on a computer or over the Internet
  • Colored LEDs alert you to rate-tier changes, high demand, cost or other user-defined parameters
  • Compatible with numerous energy or demand-rate billing systems, including fixed, time-of-use, step/tiered, seasonal, demand, or any combination of those mentioned
  • Accommodates taxes, fixed charges, and fuel surcharges to accurately reflect the monthly electric bill
  • The Energy Control Center (ECC) is the communication hub for the system

TED Pro MTU

The Measuring Transmitting Unit (MTU) measures the energy consumption, demand voltage, current, and power factor. It is designed for three-phase systems in small-to-medium size commercial, institutional and industrial environments. It is suitable for any three-phase system up to 2000A. It has two options for data-communication between MTU and ECC: PLC or Ethernet.

The MTU is generally located at the main electrical panel and transmits the information collected over the building's existing electrical wiring, using state-of-the-art Power Line Carrier communications (PLC) to an ECC which receives and interprets the data. Multiple MTUs can be used to give individual measurement of panels or loads. For systems with solar, wind or other alternative generation, TED will provide the user consumption, generation and net usage.

TED Pro ECC

The Energy Control Center (ECC) is the communication hub for the system. It receives raw energy-use data from the MTU(s), interprets the data and calculates the current energy cost, cost today, month-to-date, and various other calculations. The ECC can be configured to communicate with display devices, computers, networks, mobile devices, thermostats, and load control devices via Ethernet, PLC, or WiFi.

Go further with these options:

  • Multiple MTUs can be added to separately measure various loads or generation
  • TED Spyder:
    • Mounts in, or beside the electrical panel and is connected to the MTU
    • Records detailed usage of up to 8 single or multi-phase circuits
    • These individual readings are stored in the ECC for display
    • Each TED system can support up to 4 MTUs and 4 Spyders, thus monitoring up to 36 separate, individual loads
  • Multiple systems can be used and the data aggregated at a central location
  • Communication modules (ECC includes two USNAP ports, an Ethernet and USB port):
    • WiFi modules – Allow wireless communication with a router or other WiFi-enabled device
    • ZigBee modules – Allows communication with Smart Meters, Smart Thermostats and other ZigBee- enabled devices
  • Smart Thermostats:
    • WiFi or ZigBee-based

Applications

  • Commercial
  • Industrial
  • Energy monitoring

TED PRO 2000A KIT Specifications

Measuring Transmitting Unit (MTU)
Single-phase 2-wire or 3-wire Yes
Frequency 50/60 Hz
Maximum voltage - Phase/Phase 600V
Maximum voltage - Phase/Neutral 347V
Minimum voltage 180V
Maximum current - per phase 2000A
Maximum wire size 500 MCM (23mm OD)
Operating temperature -40°C<TA>+50°C
Overall accuracy Better than ±2%
Data-Receiving Unit (ECC)
Works with single phase MTU Yes
Maximum voltage - Phase/Neutral 277V
Minimum voltage - Phase/Neutral 95V
Frequency 50/60 Hz
Operating temperature +5°C<TA<+40°C
LED Power-on: Blue
Link status: Green/ Yellow
Transmit/Receive: Green/Red
Energy-use indicator bar: Green/Yellow/Red
Click here for complete specifications on the TED PRO 2000

What's included with the TED PRO 2000A KIT

  • Energy Control Center (ECC)
  • Measuring Transmitting Unit (MTU PRO)
  • 3 x 24" 2000A Rogowski Coils
  • MTU Power Cable
  • ECC Power Cable
  • Ethernet Cable
  • Footprints Software
  • Installation Manual

Accessories

Click on a category to view a selection of compatible accessories with the TED PRO 2000A KIT Commercial Three-Phase Energy Monitoring System with Rogowski Coils, 2000A.

TED RC2001 Rogowski Coil, 2000A RC2001
Featuring a flexible 36" Rogowski Coil that can measure up to 2000A. To be used in conjunction with the MTU PRO-RC.
$150.00 USD

Learn More

TED MTU Pro Three-Phase Measuring Transmitting Unit MTU PRO
Designed for three-phase systems in small-to-medium size commercial, institutional and industrial environments. It is suitable for systems that have a maximum of 600 V/1200 A, and services with a maximum of 400 to 1200 A. It offers two options for data communication between it and the ECC: PLC or Ethernet. Power cable (W022) not included.
$344.00 USD

Learn More


TED RC5001 Rogowski Coil, 5000A RC5001
Featuring a flexible 36" Rogowski Coil that can measure up to 5000A. To be used in conjunction with the MTU PRO-RC.
$189.00 USD

Learn More

Ask a question about TED PRO 2000A KIT Commercial Three-Phase Energy Monitoring System with Rogowski Coils, 2000A

Customer Reviews for the TED PRO 2000

TED PRO 2000A KIT Offers

Features

  • Designed for use in commercial or small industrial complexes on three-phase electrical systems up to 2000A
  • Allows you to monitor and manage energy usage
  • Energy use and alerts can be presented on a computer or over the Internet
  • Colored LEDs alert you to rate-tier changes, high demand, cost or other user-defined parameters
  • Compatible with numerous energy or demand-rate billing systems, including fixed, time-of-use, step/tiered, seasonal, demand, or any combination of those mentioned
  • Accommodates taxes, fixed charges, and fuel surcharges to accurately reflect the monthly electric bill
  • The Energy Control Center (ECC) is the communication hub for the system

TED Pro MTU

The Measuring Transmitting Unit (MTU) measures the energy consumption, demand voltage, current, and power factor. It is designed for three-phase systems in small-to-medium size commercial, institutional and industrial environments. It is suitable for any three-phase system up to 2000A. It has two options for data-communication between MTU and ECC: PLC or Ethernet.

The MTU is generally located at the main electrical panel and transmits the information collected over the building's existing electrical wiring, using state-of-the-art Power Line Carrier communications (PLC) to an ECC which receives and interprets the data. Multiple MTUs can be used to give individual measurement of panels or loads. For systems with solar, wind or other alternative generation, TED will provide the user consumption, generation and net usage.

TED Pro ECC

The Energy Control Center (ECC) is the communication hub for the system. It receives raw energy-use data from the MTU(s), interprets the data and calculates the current energy cost, cost today, month-to-date, and various other calculations. The ECC can be configured to communicate with display devices, computers, networks, mobile devices, thermostats, and load control devices via Ethernet, PLC, or WiFi.

Go further with these options:

  • Multiple MTUs can be added to separately measure various loads or generation
  • TED Spyder:
    • Mounts in, or beside the electrical panel and is connected to the MTU
    • Records detailed usage of up to 8 single or multi-phase circuits
    • These individual readings are stored in the ECC for display
    • Each TED system can support up to 4 MTUs and 4 Spyders, thus monitoring up to 36 separate, individual loads
  • Multiple systems can be used and the data aggregated at a central location
  • Communication modules (ECC includes two USNAP ports, an Ethernet and USB port):
    • WiFi modules – Allow wireless communication with a router or other WiFi-enabled device
    • ZigBee modules – Allows communication with Smart Meters, Smart Thermostats and other ZigBee- enabled devices
  • Smart Thermostats:
    • WiFi or ZigBee-based

Applications

  • Commercial
  • Industrial
  • Energy monitoring

TED PRO 2000A KIT Specifications

Measuring Transmitting Unit (MTU)
Single-phase 2-wire or 3-wire Yes
Frequency 50/60 Hz
Maximum voltage - Phase/Phase 600V
Maximum voltage - Phase/Neutral 347V
Minimum voltage 180V
Maximum current - per phase 2000A
Maximum wire size 500 MCM (23mm OD)
Operating temperature -40°C<TA>+50°C
Overall accuracy Better than ±2%
Data-Receiving Unit (ECC)
Works with single phase MTU Yes
Maximum voltage - Phase/Neutral 277V
Minimum voltage - Phase/Neutral 95V
Frequency 50/60 Hz
Operating temperature +5°C<TA<+40°C
LED Power-on: Blue
Link status: Green/ Yellow
Transmit/Receive: Green/Red
Energy-use indicator bar: Green/Yellow/Red
Click here for complete specifications on the TED PRO 2000

What's included with the TED PRO 2000A KIT

  • Energy Control Center (ECC)
  • Measuring Transmitting Unit (MTU PRO)
  • 3 x 24" 2000A Rogowski Coils
  • MTU Power Cable
  • ECC Power Cable
  • Ethernet Cable
  • Footprints Software
  • Installation Manual

Accessories

Click on a category to view a selection of compatible accessories with the TED PRO 2000A KIT Commercial Three-Phase Energy Monitoring System with Rogowski Coils, 2000A.

TED RC2001 Rogowski Coil, 2000A RC2001
Featuring a flexible 36" Rogowski Coil that can measure up to 2000A. To be used in conjunction with the MTU PRO-RC.
$150.00 USD

Learn More

TED MTU Pro Three-Phase Measuring Transmitting Unit MTU PRO
Designed for three-phase systems in small-to-medium size commercial, institutional and industrial environments. It is suitable for systems that have a maximum of 600 V/1200 A, and services with a maximum of 400 to 1200 A. It offers two options for data communication between it and the ECC: PLC or Ethernet. Power cable (W022) not included.
$344.00 USD

Learn More


TED RC5001 Rogowski Coil, 5000A RC5001
Featuring a flexible 36" Rogowski Coil that can measure up to 5000A. To be used in conjunction with the MTU PRO-RC.
$189.00 USD

Learn More

Ask a question about TED PRO 2000A KIT Commercial Three-Phase Energy Monitoring System with Rogowski Coils, 2000A

Customer Reviews for the TED PRO 2000

More TED Products