Kyoritsu 5001-02 Leak Logger

Model: 5001-02 | Order No: KEW5001-02

Kyoritsu 5001-02 Leak Logger-


Downloads:

Kyoritsu 5001-02 Leak Logger

Model: 5001-02 | Order No: KEW5001-02

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Kyoritsu 5020 AC Current/Voltage Data Logger, 3 channels-

Kyoritsu 5020 AC Current/Voltage Data Logger, 3 channels

Model: 5020 | Order No: KEW5020

Three-channel data logger capable of measuring power quality including reference voltage, swell, dip and short power interruptions using four recording modes (normal, trigger, capture, and power quality analysis). Stores up to 60,000 measurements using one channel. .


Kyoritsu 5001-02 Leak Logger

THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT 60,000 DATA IS RECORDED 60,000 data is recorded when 1ch is used and when three all channels are used, 20,000 data is recorded for each channel
  • Continuous measurement time.About 40 days
  • Data where it doesn’t disappear even if battery is consumed.Data doesn’t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged. (warranty for 10 years)
  • Battery residual display.The battery state is displayed by 4 stages. (When blinking is displayed, it is possible to measure for about one day)
  • The present time, recording intervals, the start of recording, the recording method, the name of monitoring site and the comment can be set by using supplied software
Specification:
  • Operation system: Successive approximation
  • Input: AC Voltage (AC 100mV/A)
  • Maximum Circuit Voltage: AC 170mVrms, 250mV Peak value
  • Number of input channel: 3 channels
  • Measurement method: True RMS
  • Measurement interval: 1,2,5,10,15,20,30 sec. / 1,2,5,10,15,20,30,60 min.
  • Over Range Indication: "OL" mark appears when exceeding measuring range
  • Warning of voltage of battery: Battery mark display of 4 stages
  • Battery life: about 40 days on the event record mode ( normal temp. )
  • Insulation resistance: 50M? or more
  • Dimensions: 111 (L) x 60 (W) x 42 (D) mm
  • Weight: approx. 315g (include batteries)
  • The maximum display: 1049 counts
  • Applicable standards:
  • IEC 61010-1:2001 CAT.III 300V Pollution degree 2
  • IEC 61326 (EMC Standard)
  • Power Source: Alkaline battery LR6 x 6
Accessories:
  • Instruction Manual
  • Alkaline battery LR6
  • Softwear for making graphs (CD)
  • 7148 (USB cable)
  • 9118 (Soft Case)
Optional
  • 7185 (Extension Cable)
  • 8141 / 8142 / 8143 (Leakage current clamp sensor)
  • 9119 (Hard carry case) 9135 (Carrying bag)
Model 5001-01 Leak logger (Long life type) : 5001×1 Leakage clamp sensor:
  • 8141(Ø24mm)×1
  • 8142(Ø40mm)×1
  • 8143(Ø68mm)×1
Model 5001-02 Leak logger (Long life type) : 5001×1 Leakage clamp sensor:
  • 8142(Ø40mm)×1
  • 8143(Ø68mm)×1

What's included with the Kyoritsu 5001-02

  • Kyoritsu 5001-02 Leak Logger

Ask a question about Kyoritsu 5001-02 Leak Logger

Customer Reviews for the Kyoritsu 5001-02

Kyoritsu 5001-02 Leak Logger

THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT 60,000 DATA IS RECORDED 60,000 data is recorded when 1ch is used and when three all channels are used, 20,000 data is recorded for each channel
  • Continuous measurement time.About 40 days
  • Data where it doesn’t disappear even if battery is consumed.Data doesn’t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged. (warranty for 10 years)
  • Battery residual display.The battery state is displayed by 4 stages. (When blinking is displayed, it is possible to measure for about one day)
  • The present time, recording intervals, the start of recording, the recording method, the name of monitoring site and the comment can be set by using supplied software
Specification:
  • Operation system: Successive approximation
  • Input: AC Voltage (AC 100mV/A)
  • Maximum Circuit Voltage: AC 170mVrms, 250mV Peak value
  • Number of input channel: 3 channels
  • Measurement method: True RMS
  • Measurement interval: 1,2,5,10,15,20,30 sec. / 1,2,5,10,15,20,30,60 min.
  • Over Range Indication: "OL" mark appears when exceeding measuring range
  • Warning of voltage of battery: Battery mark display of 4 stages
  • Battery life: about 40 days on the event record mode ( normal temp. )
  • Insulation resistance: 50M? or more
  • Dimensions: 111 (L) x 60 (W) x 42 (D) mm
  • Weight: approx. 315g (include batteries)
  • The maximum display: 1049 counts
  • Applicable standards:
  • IEC 61010-1:2001 CAT.III 300V Pollution degree 2
  • IEC 61326 (EMC Standard)
  • Power Source: Alkaline battery LR6 x 6
Accessories:
  • Instruction Manual
  • Alkaline battery LR6
  • Softwear for making graphs (CD)
  • 7148 (USB cable)
  • 9118 (Soft Case)
Optional
  • 7185 (Extension Cable)
  • 8141 / 8142 / 8143 (Leakage current clamp sensor)
  • 9119 (Hard carry case) 9135 (Carrying bag)
Model 5001-01 Leak logger (Long life type) : 5001×1 Leakage clamp sensor:
  • 8141(Ø24mm)×1
  • 8142(Ø40mm)×1
  • 8143(Ø68mm)×1
Model 5001-02 Leak logger (Long life type) : 5001×1 Leakage clamp sensor:
  • 8142(Ø40mm)×1
  • 8143(Ø68mm)×1

What's included with the Kyoritsu 5001-02

  • Kyoritsu 5001-02 Leak Logger

Ask a question about Kyoritsu 5001-02 Leak Logger

Customer Reviews for the Kyoritsu 5001-02

More Kyoritsu Products