The clamp-on power meter measures demand and harmonics, as well as electrical parameters such as voltage, current, power, power factor, and integrated power (watthours).
The clamp-on power meter measures demand and harmonics, as well as electrical parameters such as voltage, current, power, power factor, and integrated power (watthours).
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
Features
Measurement Line and Number of Circuits | Single-phase 2-wires (4 circuits), single-phase 3-wires (2 circuits), three-phases 3-wires (2 or 1 circuit), and three-phases 4-wires (1 circuit) Note: 50 or 60 Hz, and that share the same voltage line |
Measurement | Items: Voltage, current, active/ reactive/ apparent power, active/ reactive power integration, power factor, frequency, harmonic waveform value (up to 40th order) Range: [Voltage] 150 V to 600 V AC, 3 ranges, [Current] 500 mA to 5 kA AC (depends on current sensor in use), [Power] 75 W to 900 kW (depends on combination of voltage, current range, and measurement line) |
Basic Accuracy | AC Voltage: ±0.2 % rdg. ±0.1 % f.s. AC Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy (at power factor = 1) Clamp on sensor 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each sensor models) |
Measurement Method | Digital sampling, PLL synchronization or 50/60 Hz fixed clock |
Display Refresh Rate | 2 times per seconds (except when a PC card accessing, or RS-232C communications) |
Data Save Interval | Standard interval: 1 to 30 seconds, 1 to 60 minutes, 13 selects Fast interval: A single waveform, or 0.1, 0.2, or 0.5 seconds (at instant value only) |
Frequency Characteristics | Fundamental waveforms up to the 50th order ±3% f.s. + measurement accuracy (of a 45 to 66 Hz fundamental waveform) |
Other Functions | Error connect check, language selection, display hold, setting backup, power shut off management, key lock, [3169-21 only] D/A output 4 channels, (±5 V DC f.s.) |
Power Supply | 100 to 240 V AC, 50/60 Hz, 30 VA maximum |
Dimensions | 8.27 x 6.3 x 2.36" (210 x 160 x 60 mm) |
Weight | 42.3 oz (1.2 kg) |
Measurement Line and Number of Circuits | Single-phase 2-wires (4 circuits), single-phase 3-wires (2 circuits), three-phases 3-wires (2 or 1 circuit), and three-phases 4-wires (1 circuit) Note: 50 or 60 Hz, and that share the same voltage line |
Measurement | Items: Voltage, current, active/ reactive/ apparent power, active/ reactive power integration, power factor, frequency, harmonic waveform value (up to 40th order) Range: [Voltage] 150 V to 600 V AC, 3 ranges, [Current] 500 mA to 5 kA AC (depends on current sensor in use), [Power] 75 W to 900 kW (depends on combination of voltage, current range, and measurement line) |
Basic Accuracy | AC Voltage: ±0.2 % rdg. ±0.1 % f.s. AC Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy (at power factor = 1) Clamp on sensor 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each sensor models) |
Measurement Method | Digital sampling, PLL synchronization or 50/60 Hz fixed clock |
Display Refresh Rate | 2 times per seconds (except when a PC card accessing, or RS-232C communications) |
Data Save Interval | Standard interval: 1 to 30 seconds, 1 to 60 minutes, 13 selects Fast interval: A single waveform, or 0.1, 0.2, or 0.5 seconds (at instant value only) |
Frequency Characteristics | Fundamental waveforms up to the 50th order ±3% f.s. + measurement accuracy (of a 45 to 66 Hz fundamental waveform) |
Other Functions | Error connect check, language selection, display hold, setting backup, power shut off management, key lock, [3169-21 only] D/A output 4 channels, (±5 V DC f.s.) |
Power Supply | 100 to 240 V AC, 50/60 Hz, 30 VA maximum |
Dimensions | 8.27 x 6.3 x 2.36" (210 x 160 x 60 mm) |
Weight | 42.3 oz (1.2 kg) |