The meter generates reliable data on current. It clamps directly to the current transformers in the system.
The meter generates reliable data on current. It clamps directly to the current transformers in the system.
The Fluke I400S-EL Clamp-On Current Transformers provides accurate measurements of the current running through a system. The simple design can easily be attached to most circuits to begin operating and delivering data to the user. It utilizes existing infrastructure to secure the clamp without disrupting the operation of the circuit itself.
Features
Nominal Current Range | 40 A range: 0.5 to 40 A 400 A range: 5 to 400 A |
Basic Accuracy | 40 A range: 2% + 0.015 A (45 to 400 Hz) 400 A range: 2% + 0.04 A (45 to 400 Hz) |
Phase Shift | 40 A range: 0.5 to 1 A, Unspecified 1 to 5 A, 4° 5 to 10 A, 3° 10 to 20 A, 3° 20 to 40 A, 2° 40 A to 400 A, NA 400 A range: 0.5 to 1 A, NA 1 to 5 A, NA 5 to 10 A, Unspecified 10 to 20 A, 2° 20 to 40 A, 2° 40 to 400 A, 1.5° |
Typical Bandwidth | 40 A range: 5 to 10 kHz 400 A range: 5 to 10 kHz |
Output Levels | 40 A range: 10 mV/A 400 A range: 1 mV/A |
Crest Factor | 40 A range: ≤ 3 400 A range: ≤ 3 to 300 A, ≤ 2.5 to 400 A |
Safety | CAT IV, 600 V, CAT III, 1000 V |
Maximum Non-Destructive Current | 1000 V AC |
Maximum Conductor Size | 1.25" (32 mm) |
Output Cable Length | 8.2' (2.5 m) |
BNC Adapter | Yes |
Dimensions | 5.9 x 2.7 x 1.18" (150 x 70 x 30 mm) |
Weight | 0.3 lbs (114 g) |
Click on a category to view a selection of compatible accessories with the Fluke I400S-EL Clamp-On Meter for the current transformers, 400 A.
Nominal Current Range | 40 A range: 0.5 to 40 A 400 A range: 5 to 400 A |
Basic Accuracy | 40 A range: 2% + 0.015 A (45 to 400 Hz) 400 A range: 2% + 0.04 A (45 to 400 Hz) |
Phase Shift | 40 A range: 0.5 to 1 A, Unspecified 1 to 5 A, 4° 5 to 10 A, 3° 10 to 20 A, 3° 20 to 40 A, 2° 40 A to 400 A, NA 400 A range: 0.5 to 1 A, NA 1 to 5 A, NA 5 to 10 A, Unspecified 10 to 20 A, 2° 20 to 40 A, 2° 40 to 400 A, 1.5° |
Typical Bandwidth | 40 A range: 5 to 10 kHz 400 A range: 5 to 10 kHz |
Output Levels | 40 A range: 10 mV/A 400 A range: 1 mV/A |
Crest Factor | 40 A range: ≤ 3 400 A range: ≤ 3 to 300 A, ≤ 2.5 to 400 A |
Safety | CAT IV, 600 V, CAT III, 1000 V |
Maximum Non-Destructive Current | 1000 V AC |
Maximum Conductor Size | 1.25" (32 mm) |
Output Cable Length | 8.2' (2.5 m) |
BNC Adapter | Yes |
Dimensions | 5.9 x 2.7 x 1.18" (150 x 70 x 30 mm) |
Weight | 0.3 lbs (114 g) |
Click on a category to view a selection of compatible accessories with the Fluke I400S-EL Clamp-On Meter for the current transformers, 400 A.