1.888.610.7664

sales@GlobalTestSupply.com

Customer Reviews

Dent CT-R16-A4U-8M RoCoil Flexible Rope Current Transformer, 22.96' lead

Model: CT-R16-A4U-8M | Order No: CTR16A4U-8M

Dent CT-R16-A4U-8M RoCoil Flexible Rope Current Transformer, 22.96' lead-


Downloads:

Dent CT-R16-A4U-8M RoCoil Flexible Rope Current Transformer, 22.96' lead

Model: CT-R16-A4U-8M | Order No: CTR16A4U-8M

The rope-style current transformer is 16" in length with a 22.96' lead. It features a large window size, a wide current range, and mechanical flexibility for mounting in tight quarters. RoCoil provides accurate, non-intrusive measurements of AC combined with easy placement around cable bundles, large bus bars, and irregularly shaped conductors.

The rope-style current transformer is 16" in length with a 22.96' lead. It features a large window size, a wide current range, and mechanical flexibility for mounting in tight quarters. RoCoil provides accurate, non-intrusive measurements of AC combined with easy placement around cable bundles, large bus bars, and irregularly shaped conductors.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Dent CTRCFX16L1800A7MSTV1 RoCoil Flexible Current Transformer, Rogowski coil, 16", 275.6" leads-

Dent CTRCFX16L1800A7MSTV1 RoCoil Flexible Current Transformer, Rogowski coil, 16", 275.6" leads

Model: CTRCFX16L1800A7MSTV1

The RoCoil flexible current transformers have been designed for accurate, non-intrusive measurement of AC current over a wide dynamic range, where conventional rigid core sensors are unsuitable. This model has a length of 16" (40 cm) with 275.6" (7 m) leads.

The replacement product is only available on our affiliate GlobalTestSupply.com website. Don't worry your cart and information will be brought over.


Not what you're looking for? Let’s do a search and help you find what you need.


Dent CT-R16-A4U-8M Offers

The transformer is designed for accurate nonintrusive measurement of AC current, pulsed DC or distorted waveforms where conventional rigid core sensors are unsuitable. This type of sensor may be used to measure AC current over a wide dynamic range and from 20 Hz to 5 kHz.

Features

  • Designed for accurate, non-intrusive measurements
  • Fits into panels where rigid core CTs are unsuitable or simply won't fit
  • Used to measure AC currents over a wide, dynamic range
  • Building sub-metering
  • Test and measurement
  • Current sensors

Dent CT-R16-A4U-8M Specifications

Output Signal 131 mV/1000 A at 60 Hz109.2 mV/1000 A at 50 Hz
Phasing Arrow points towards load
Phase Shift <0.2° at 50/60 Hz
Frequency Range 20 Hz to 5 kHz
Useful Current Range 5 to 5000 A AC
Linearity ±0.2%
Temperature Sensitivity 0.07% per °C
Coil Materials Blue thermoplastic rubber, flame retardant UL 94 V-0 rated
Coupling Materials PA6 UL 94 V-0 rated
Shielding 100% transducer, 100% output lead
Working Temperature -4 to 158 °F (-20 to 70 °C)
Dimensions Window Size: 4.5" (11.5 cm)
Sensor Coil Outer Diameter: 5.5" (13.9 cm)
Sensor Length: 15.8" (40 cm)
Locking Connector Outer Diameter: 0.78" (2.0 cm)
Sensor Coil Diameter: 0.47" (1.2 cm)
Wire Lead Total Length: 118" (3 m)
Click here for complete specifications on the Dent CT-R16-A4U-8M

What's included with the Dent CT-R16-A4U-8M

  • Dent CT-R16-A4U-8M RoCoil Flexible Rope Current Transformer, 22.96' lead

Ask a question about Dent CT-R16-A4U-8M RoCoil Flexible Rope Current Transformer, 22.96' lead

Customer Reviews for the Dent CT-R16-A4U-8M

Dent CT-R16-A4U-8M Offers

The transformer is designed for accurate nonintrusive measurement of AC current, pulsed DC or distorted waveforms where conventional rigid core sensors are unsuitable. This type of sensor may be used to measure AC current over a wide dynamic range and from 20 Hz to 5 kHz.

Features

  • Designed for accurate, non-intrusive measurements
  • Fits into panels where rigid core CTs are unsuitable or simply won't fit
  • Used to measure AC currents over a wide, dynamic range
  • Building sub-metering
  • Test and measurement
  • Current sensors

Dent CT-R16-A4U-8M Specifications

Output Signal 131 mV/1000 A at 60 Hz109.2 mV/1000 A at 50 Hz
Phasing Arrow points towards load
Phase Shift <0.2° at 50/60 Hz
Frequency Range 20 Hz to 5 kHz
Useful Current Range 5 to 5000 A AC
Linearity ±0.2%
Temperature Sensitivity 0.07% per °C
Coil Materials Blue thermoplastic rubber, flame retardant UL 94 V-0 rated
Coupling Materials PA6 UL 94 V-0 rated
Shielding 100% transducer, 100% output lead
Working Temperature -4 to 158 °F (-20 to 70 °C)
Dimensions Window Size: 4.5" (11.5 cm)
Sensor Coil Outer Diameter: 5.5" (13.9 cm)
Sensor Length: 15.8" (40 cm)
Locking Connector Outer Diameter: 0.78" (2.0 cm)
Sensor Coil Diameter: 0.47" (1.2 cm)
Wire Lead Total Length: 118" (3 m)
Click here for complete specifications on the Dent CT-R16-A4U-8M

What's included with the Dent CT-R16-A4U-8M

  • Dent CT-R16-A4U-8M RoCoil Flexible Rope Current Transformer, 22.96' lead

Ask a question about Dent CT-R16-A4U-8M RoCoil Flexible Rope Current Transformer, 22.96' lead

Customer Reviews for the Dent CT-R16-A4U-8M

More Dent Products