AEMC L104 4-Channel 0-1VAC Datalogger

Model: L104 | Order No: 2126.10 | UPC: 685338140477

AEMC L104 4-Channel 0-1VAC Datalogger-


Downloads:

AEMC L104 4-Channel 0-1VAC Datalogger

Model: L104 | Order No: 2126.10

4-Channel, True RMS, Bluetooth, 0-1V AC, DataView Software.

4-Channel, True RMS, Bluetooth, 0-1V AC, DataView Software.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

AEMC L452 DC Current/Voltage Data Logger, 100mV/1V/10V DC-

AEMC L452 DC Current/Voltage Data Logger, 100mV/1V/10V DC

Model: L452 | Order No: 2153.51

This Bluetooth-enabled logger and event counter records DC voltage, DC current, and 4 to 20mA pulse counts. Features two input channels that allows the user to connect the Data Logger to various types of sensors as pressure, temperature, flow, humidity, and more.


Not what you're looking for? Let’s do a search and help you find what you need.


L104 AC Current Loggers

The Simple Logger® II, Model L104, is a 4-channel AC current recording device powered by alkaline batteries. The compatible current probes are Models MN93-BK, MN193-BK or SR193-BK (sold separately). Full scale ranges from 5A to 1200A are dependent on probe selection. Harmonic measurements are calculated from 64 samples taken on each AC cycle measured and are available in real-time using the included DataView® software.

The Simple Logger® II Model L104 stores TRMS measurements at user programmable rates from eight times per second to one per day. TRMS calculations are performed on a single line cycle. The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.

Bluetooth communication provides for the real-time measurement viewing, configuring the instrument and transfer of data from the instrument's internal memory to the computer for monitoring, storing and/or analysis without the need of connecting a cable.


Applications

  • Single/split phase and 3-phase load monitoring
  • Neutral and ground current monitoring
  • Intermittent problem detection
  • Harmonic current monitoring using DataView® software
  • Machine load monitoring
  • Fault current detection
  • Load profiling

Key Features

  • TRMS voltage recording up to 1200A
  • 64 samples per cycle
  • Programmable storage rates from 8 per second to 1 every day
  • Four user selectable storage modes
  • Stores up to 1,000,000 measurements in non-volatile memory
  • Up to 180 days or more of operation from standard alkaline batteries dependent on sample rate
  • Lightweight, compact, fits anywhere
  • Six LED indicators quickly and clearly display logger status
  • Supported current probes: SR193-BK, MN193-BK or MN93-BK
  • Includes FREE DataView® software for data storage, real-time waveform display, analysis & report generation
  • Wireless Bluetooth data communication
  • Supported current probes: SR193-BK, MN193-BK or MN93-BK
  • Safety Ratings 600V CAT IV; 1000V CAT III

Specifications

SPECIFICATIONS
Models L104
Electrical
Channels Four
Input Connection One connector per channel
Voltage Range 0 to 1V ac (output from probe)
Accuracy (50/60Hz) 0 to 10mV unspecified 10 to 50mV: ±(0.5% of Reading + 1mV) 50 to 1000mV: ±(0.5% of Reading + 0.5mV)
Input Impedance 100kΩ
Sample Rate 64 samples/cycle
Storage Rate Programmable from 125ms to 1 per day
Storage Mode Start/Stop, FIFO, Extended Recording Mode (XRM ™ ) and Store on Alarm
Recording Length 15 minutes to 8 weeks, programmable using DataView ®
Memory 1,000,000 measurement (2MB) The recorded data is stored in non-volatile memory & retained even if the battery is low or removed.
Communication Bluetooth (Class 2)
Power Source 4 x 1.5V C-cell Alkaline batteries
Battery Life Up to > 180 days or more (dependent on storage rate)
Mechanical
Dimensions (without removable connector) 5.904 x 5.904 x 3.568" (150 x 150 x 91mm)
Weight (with battery) 2.1 lbs (0.95kg)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
Click here for complete specifications on the AEMC Instruments L104

What's included with the AEMC Instruments L104

  • AEMC L104 4-Channel 0-1VAC Datalogger

Accessories

Click on a category to view a selection of compatible accessories with the AEMC L104 4-Channel 0-1VAC Datalogger.

AEMC MN193-BK Current Transformer for the L104, L564, PowerPad, and PEL Series MN193-BK
For use with AEMC Power Quality Instruments 8220, 8230, and 3945.
$322.05 USD

was $339.00


Learn More

AEMC MN93-BK AC Current Probe, 200 A, 10' MN93-BK
Features 10' lead and 200 A capacity, this probe is designed for use with 3945/3945-B, 8220, 8230, 8333, 8335, 8336, PEL Series, L104, and L564.
$239.40 USD

was $252.00


Learn More

AEMC SR193-BK AC Current Probe, 1200 A SR193-BK
Designed for use with 3945/3945B/8220/8230/8333/8335/8336 power quality analyzers, PEL 102/103/105 power and energy loggers, and L104/L564 simple loggers II. Features a current range of 1200 A, and a clamping diameter of 2" (52 mm).
$412.30 USD

was $434.00


Learn More

AEMC MR193-BK AC Current Probe for THE PowerPad and PEL Series MR193-BK
For use with AEMC 3945 PowerPad, 8220 & 8230 PowerPad Jr.
$483.55 USD

was $509.00


Learn More

Ask a question about AEMC L104 4-Channel 0-1VAC Datalogger

Customer Reviews for the AEMC Instruments L104

L104 AC Current Loggers

The Simple Logger® II, Model L104, is a 4-channel AC current recording device powered by alkaline batteries. The compatible current probes are Models MN93-BK, MN193-BK or SR193-BK (sold separately). Full scale ranges from 5A to 1200A are dependent on probe selection. Harmonic measurements are calculated from 64 samples taken on each AC cycle measured and are available in real-time using the included DataView® software.

The Simple Logger® II Model L104 stores TRMS measurements at user programmable rates from eight times per second to one per day. TRMS calculations are performed on a single line cycle. The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.

Bluetooth communication provides for the real-time measurement viewing, configuring the instrument and transfer of data from the instrument's internal memory to the computer for monitoring, storing and/or analysis without the need of connecting a cable.


Applications

  • Single/split phase and 3-phase load monitoring
  • Neutral and ground current monitoring
  • Intermittent problem detection
  • Harmonic current monitoring using DataView® software
  • Machine load monitoring
  • Fault current detection
  • Load profiling

Key Features

  • TRMS voltage recording up to 1200A
  • 64 samples per cycle
  • Programmable storage rates from 8 per second to 1 every day
  • Four user selectable storage modes
  • Stores up to 1,000,000 measurements in non-volatile memory
  • Up to 180 days or more of operation from standard alkaline batteries dependent on sample rate
  • Lightweight, compact, fits anywhere
  • Six LED indicators quickly and clearly display logger status
  • Supported current probes: SR193-BK, MN193-BK or MN93-BK
  • Includes FREE DataView® software for data storage, real-time waveform display, analysis & report generation
  • Wireless Bluetooth data communication
  • Supported current probes: SR193-BK, MN193-BK or MN93-BK
  • Safety Ratings 600V CAT IV; 1000V CAT III

Specifications

SPECIFICATIONS
Models L104
Electrical
Channels Four
Input Connection One connector per channel
Voltage Range 0 to 1V ac (output from probe)
Accuracy (50/60Hz) 0 to 10mV unspecified 10 to 50mV: ±(0.5% of Reading + 1mV) 50 to 1000mV: ±(0.5% of Reading + 0.5mV)
Input Impedance 100kΩ
Sample Rate 64 samples/cycle
Storage Rate Programmable from 125ms to 1 per day
Storage Mode Start/Stop, FIFO, Extended Recording Mode (XRM ™ ) and Store on Alarm
Recording Length 15 minutes to 8 weeks, programmable using DataView ®
Memory 1,000,000 measurement (2MB) The recorded data is stored in non-volatile memory & retained even if the battery is low or removed.
Communication Bluetooth (Class 2)
Power Source 4 x 1.5V C-cell Alkaline batteries
Battery Life Up to > 180 days or more (dependent on storage rate)
Mechanical
Dimensions (without removable connector) 5.904 x 5.904 x 3.568" (150 x 150 x 91mm)
Weight (with battery) 2.1 lbs (0.95kg)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
Click here for complete specifications on the AEMC Instruments L104

What's included with the AEMC Instruments L104

  • AEMC L104 4-Channel 0-1VAC Datalogger

Accessories

Click on a category to view a selection of compatible accessories with the AEMC L104 4-Channel 0-1VAC Datalogger.

AEMC MN193-BK Current Transformer for the L104, L564, PowerPad, and PEL Series MN193-BK
For use with AEMC Power Quality Instruments 8220, 8230, and 3945.
$322.05 USD

was $339.00


Learn More

AEMC MN93-BK AC Current Probe, 200 A, 10' MN93-BK
Features 10' lead and 200 A capacity, this probe is designed for use with 3945/3945-B, 8220, 8230, 8333, 8335, 8336, PEL Series, L104, and L564.
$239.40 USD

was $252.00


Learn More

AEMC SR193-BK AC Current Probe, 1200 A SR193-BK
Designed for use with 3945/3945B/8220/8230/8333/8335/8336 power quality analyzers, PEL 102/103/105 power and energy loggers, and L104/L564 simple loggers II. Features a current range of 1200 A, and a clamping diameter of 2" (52 mm).
$412.30 USD

was $434.00


Learn More

AEMC MR193-BK AC Current Probe for THE PowerPad and PEL Series MR193-BK
For use with AEMC 3945 PowerPad, 8220 & 8230 PowerPad Jr.
$483.55 USD

was $509.00


Learn More

Ask a question about AEMC L104 4-Channel 0-1VAC Datalogger

Customer Reviews for the AEMC Instruments L104

More AEMC Instruments Products