TED PRO MTU4 MTU/CT Set for the Pro Commercial, 400A

Model: TED PRO MTU4

TED PRO MTU4 MTU/CT Set for the Pro Commercial, 400A-


Downloads: datasheet

TED PRO MTU4 MTU/CT Set for the Pro Commercial, 400A

Model: TED PRO MTU4

This set is designed to monitor an additional main breaker panel, subpanel, or wind/solar installation up to 400A. To be used in conjunction with any Pro Commercial kit.

This set is designed to monitor an additional main breaker panel, subpanel, or wind/solar installation up to 400A. To be used in conjunction with any Pro Commercial kit.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


TED PRO MTU4 Offers

Designed to monitor an additional main breaker panel, subpanel, or wind/solar installation up to 400A. It measures the energy consumption, demand voltage, current, and power factor. It is designed for three-phase systems in small-to-medium size commercial, institutional and industrial environments. It has two options for data-communication between MTU and ECC: PLC or Ethernet.

The MTU is generally located at the main electrical panel and transmits the information collected over the building's existing electrical wiring, using state-of-the-art Power Line Carrier communications (PLC) to an ECC which receives and interprets the data. Multiple MTUs can be used to give individual measurement of panels or loads. For systems with solar, wind or other alternative generation, TED will provide the user consumption, generation and net usage.

MTU Facts

  • 'MTU' stands for "Measuring Transmitting Unit"
  • An installed MTU (in a residence) will typically have 2 CTs (current transformers) - more CTs in three-phase systems
  • A TED system requires at least one MTU to operate
  • Accurate to within +/- 1%
  • It samples energy-data at a rate of 8,000 times per second, takes the average, and transmits that data each second to the ECC (Energy Control Center)
  • It will post one measurement every one second - which is the combined measurement of the 2 CTs (generally connected to the main circuits)
  • If there is a Spyder connected to the MTU, the Spyder measurements will post as independent data
  • Data posted includes voltage, power factor, kW

TED PRO MTU4 Specifications

Single-phase 2-wire or 3-wire Yes
Frequency 50/60 Hz
Maximum voltage - Phase/Phase 600V
Maximum voltage - Phase/Neutral 347V
Minimum voltage 180V
Maximum current - per phase 400A
Maximum wire size 500 MCM (23mm OD)
Operating temperature -40°C<TA>+50°C
Overall accuracy Better than ±2%
Click here for complete specifications on the TED TED PRO MTU4

What's included with the TED PRO MTU4

  • Measuring Transmitting Unit
  • 3 x 400A CTs

Ask a question about TED PRO MTU4 MTU/CT Set for the Pro Commercial, 400A

Customer Reviews for the TED TED PRO MTU4

TED PRO MTU4 Offers

Designed to monitor an additional main breaker panel, subpanel, or wind/solar installation up to 400A. It measures the energy consumption, demand voltage, current, and power factor. It is designed for three-phase systems in small-to-medium size commercial, institutional and industrial environments. It has two options for data-communication between MTU and ECC: PLC or Ethernet.

The MTU is generally located at the main electrical panel and transmits the information collected over the building's existing electrical wiring, using state-of-the-art Power Line Carrier communications (PLC) to an ECC which receives and interprets the data. Multiple MTUs can be used to give individual measurement of panels or loads. For systems with solar, wind or other alternative generation, TED will provide the user consumption, generation and net usage.

MTU Facts

  • 'MTU' stands for "Measuring Transmitting Unit"
  • An installed MTU (in a residence) will typically have 2 CTs (current transformers) - more CTs in three-phase systems
  • A TED system requires at least one MTU to operate
  • Accurate to within +/- 1%
  • It samples energy-data at a rate of 8,000 times per second, takes the average, and transmits that data each second to the ECC (Energy Control Center)
  • It will post one measurement every one second - which is the combined measurement of the 2 CTs (generally connected to the main circuits)
  • If there is a Spyder connected to the MTU, the Spyder measurements will post as independent data
  • Data posted includes voltage, power factor, kW

TED PRO MTU4 Specifications

Single-phase 2-wire or 3-wire Yes
Frequency 50/60 Hz
Maximum voltage - Phase/Phase 600V
Maximum voltage - Phase/Neutral 347V
Minimum voltage 180V
Maximum current - per phase 400A
Maximum wire size 500 MCM (23mm OD)
Operating temperature -40°C<TA>+50°C
Overall accuracy Better than ±2%
Click here for complete specifications on the TED TED PRO MTU4

What's included with the TED PRO MTU4

  • Measuring Transmitting Unit
  • 3 x 400A CTs