This line of power & energy meters is designed for revenue grade commercial metering applications. Each meter includes CTs calibrated to the meter for greater system-wide accuracy. Available for single to three phase applications from 120 to 480V.
This line of power & energy meters is designed for revenue grade commercial metering applications. Each meter includes CTs calibrated to the meter for greater system-wide accuracy. Available for single to three phase applications from 120 to 480V.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our BACNET Power Meters category for similar products.
Or let's do a search and help you find what you need:
The H81xx Series Energy Meters are easy to install and provide exceptional system accuracy, making them ideal for all submetering applications.
Each meter is factory-matched with one to three split-core CTs. The meter/CT pairs are system-calibrated to provide excellent total system accuracies of 1% from 2% to 100% of the amperage rating of the CTs (e.g., 2-100 amps with 100 amp CTs). Matching serial numbers assure that the meter and CT were calibrated together (matching does not apply if using 100A CTs).
The H81xx is easy to install. The split-core CTs eliminate the need to remove electrical conductors, reducing installation time. The meter is also capable of detecting and correcting phase reversal, eliminating the need for concern about CT load orientation. The convenient color coding of the CTs and voltage leads make correct connection simple.
Features
Applications
Voltage Tolerance | 90 to 132VAC Line-to-Neutral |
Electrical Services | 120/240 VAC with Neutral, 208Y/120 VAC Line to Neutral |
Power Consumption | 50VA |
Insulation Class | 600VAC |
Internal Isolation | 2500VAC |
LCD Display | 1.2 x 3.8" (31 x 97mm) Viewing Area, 160 Segments, Back-Lit with Green LEDs |
Sample Rate | 1280Hz |
Operating Temperature Range | 0 to 50°C (32 to 122°F) (<95%RH, Non-Condensing) |
Storage Temperature Range | -40 to 70°C (-40 to 158°F) |
Systems Accuracy | ±1% of reading from 2% to 100% of the rated current of the CTs, accomplished by matching the CTs with a meter and calibrating them as a system |
Frequency | 50/60Hz |
Protection Class | NEMA 1 |
Voltage Tolerance | 90 to 132VAC Line-to-Neutral |
Electrical Services | 120/240 VAC with Neutral, 208Y/120 VAC Line to Neutral |
Power Consumption | 50VA |
Insulation Class | 600VAC |
Internal Isolation | 2500VAC |
LCD Display | 1.2 x 3.8" (31 x 97mm) Viewing Area, 160 Segments, Back-Lit with Green LEDs |
Sample Rate | 1280Hz |
Operating Temperature Range | 0 to 50°C (32 to 122°F) (<95%RH, Non-Condensing) |
Storage Temperature Range | -40 to 70°C (-40 to 158°F) |
Systems Accuracy | ±1% of reading from 2% to 100% of the rated current of the CTs, accomplished by matching the CTs with a meter and calibrating them as a system |
Frequency | 50/60Hz |
Protection Class | NEMA 1 |