Accuenergy ACUVIM-CL-D-60-5A-P1V4 Power/Energy Meter, LCD, RS485, 5 A input, 415 Vac/300 Vdc

Model: ACUVIM-CL-D-60-5A-P1V4

Accuenergy ACUVIM-CL-D-60-5A-P1V4 Power/Energy Meter, LCD, RS485, 5 A input, 415 Vac/300 Vdc-


Downloads:

Accuenergy ACUVIM-CL-D-60-5A-P1V4 Power/Energy Meter, LCD, RS485, 5 A input, 415 Vac/300 Vdc

Model: ACUVIM-CL-D-60-5A-P1V4

Multifunction power meter with integrated LCD display, Modbus RTU output, 5 A input for current transformers and wide-range AC power supply input.

Multifunction power meter with integrated LCD display, Modbus RTU output, 5 A input for current transformers and wide-range AC power supply input.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Accuenergy Acuvim-CL Series Multifunction Power and Energy Meter with panel mounting with display, 5 A/1 A input, 100 to 415 V AC-

Accuenergy Acuvim-CL Series Multifunction Power and Energy Meter with panel mounting with display, 5 A/1 A input, 100 to 415 V AC

Model: ACUVIM-CL-D-5A-P1V4

Ideal for various standard metering projects, this multifunction power meter with energy class 0.5 harmonics up to 31st provides real-time, true-RMS measurements of current, power, voltage, energy, and many other parameters. In addition, it has a 5 A/1 A current input (selectable), a 100 to 415 V AC power supply, and a standard mount.


Accuenergy Acuvim CL-D-5A-P1 Offers

Panel metering is key to understanding energy consumption in homes, buildings, and facilities. The Accuenergy Acuvim CL includes a digital RS485 communication port running Modbus protocol. This model also includes 5A current input, 100 to 415V AC, 50/60Hz, 100 to 300V DC power supply, and integrated LCD display.

Features

  • True-RMS measurement parameters so that non-linear loads can be monitored
  • 4-quadrant energy measurement
  • Power quality analysis
  • Over/Under limit alarm
  • Max/Min statistics
  • Meter running time

Accuenergy ACUVIM-CL-D-60-5A-P1V4 Specifications

Parameters Acuvim-L Accuracy
Parameters Acuvim-L AccuracyAcuvim-EL/KL AccuracyResolutionRange
Parameters Acuvim-L Accuracy
Parameters Acuvim-L Accuracy
Parameters Acuvim-L Accuracy
Voltage 0.005
Voltage 0.5%0.5%0.1V20V~1000kV
Voltage 0.005
Voltage 0.005
Voltage 0.005
Current 0.005
Current 0.5%0.5%0.001A0~50000A
Current 0.005
Current 0.005
Current 0.005
Current Demand 0.005
Current Demand 0.5%0.5%0.001A0~50000A
Current Demand 0.005
Current Demand 0.005
Current Demand 0.005
Power 0.01
Power 1.0%0.5%1W-9999MW~9999MW
Power 0.01
Power 0.01
Power 0.01
Reactive Power 0.02
Reactive Power 2.0%0.5%1var-9999Mvar~9999Mvar
Reactive Power 0.02
Reactive Power 0.02
Reactive Power 0.02
Apparent Power 0.01
Apparent Power 1.0%0.5%0.001V0~9999MVA
Apparent Power 0.01
Apparent Power 0.01
Apparent Power 0.01
Power Demand 0.01
Power Demand 1.0%0.5%1W-9999MW~9999MW
Power Demand 0.01
Power Demand 0.01
Power Demand 0.01
Reactive Power Demand 0.02
Reactive Power Demand 2.0%0.5%1var-9999Mvar~9999Mvar
Reactive Power Demand 0.02
Reactive Power Demand 0.02
Reactive Power Demand 0.02
Apparent Power Demand 0.01
Apparent Power Demand 1.0%1VA1VA0~9999MVA
Apparent Power Demand 0.01
Apparent Power Demand 0.01
Apparent Power Demand 0.01
Power Factor 0.01
Power Factor 1.0%0.5%0.001-1.0~1.0
Power Factor 0.01
Power Factor 0.01
Power Factor 0.01
Frequency 0.002
Frequency 0.2%0.2%0.01Hz45.00~65.00Hz
Frequency 0.002
Frequency 0.002
Frequency 0.002
Energy 0.005
Energy 0.5%0.5%0.1kWh0~99999999.9kWh
Energy 0.005
Energy 0.005
Energy 0.005
Reactive Energy 0.02
Reactive Energy 2.0%0.5%0.1kvarh0~99999999.9kvarh
Reactive Energy 0.02
Reactive Energy 0.02
Reactive Energy 0.02
Apparent Energy 0.01
Apparent Energy 1.0%0.5%0.1VAh0~99999999.9kVAh
Apparent Energy 0.01
Apparent Energy 0.01
Apparent Energy 0.01
Harmonics 0.02
Harmonics 2.0%-0.01%0~100.0%
Harmonics 0.02
Harmonics 0.02
Harmonics 0.02
Running Time  
Running Time 0.1hrs0~999999999.9hrs
RS-485 (Option)
Modbus-RTU Protocol
2-wire connection, Half-duplex, Isolated
1200 to 38400 baud rate
Current Inputs (Each Channel)
Nominal Current5 A ac
Metering Range0~6 A ac
Withstand20Arms continuous100Arms for 1 second, non-recurring
Burden0.05VA (typical) @5Arms
Pickup Current10Vac
Accuracy0.5%
Voltage Inputs (Each Channel)
Nominal Full Scale400Vac L-N, 690Vac L-L (+20%)
Withstand1500Vac continuous2500Vac, 50/60Hz for 1minute
Input Impedance45Hz~65Hz
Pickup Voltage10Vac
Accuracy0.5%
Energy Accuracy (Acuvim-EL)
Active(according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Reactive(according to IEC 62053-23) Class 2
Harmonic Resolution
Metered Value2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
UniversalAC or DC
AC/DC Control Power
Operating Range100~415Vac, 50/60Hz, 100~300Vdc
Burden3W
Withstand3250Vac, 50/60Hz for 1 minute
Low Voltage DC Control Power (Optional)
Operating Range20~60Vdx
Burden3W
Digital Output (DO)(Photo-MOS)
Voltage Range0~250Vac/dc
Load Current100mA (Max)
Output Frequency25Hz, 50% Duty Ratio
Isolation Voltage2500V
Digital Output (DI)
Input Voltage Range20~250Vac/dc
Input Current (Max)2mA
Start Voltage15V
Stop Voltage5V
Pulse Frequency (Max)100Hz, 50% Duty Ratio
SOE Resolution2ms
Operation Temperature-25°C to 70°C
Storage Temperature-40°C to 85°C
Relative Humidity5% to 95% non-condensing
Pollution Degree2
Product
USAUL 61010-1
CanadacUL 61010-1
EuropeIEC 61010-1
Emission
Radiated/ConductedFCC Part 15 Subpart B, Class A
Radiated/ConductedEN 55011
HarmonicIEC 61000-3-2
Voltage FluctuationIEC 50081-2
Radio InterferenceIEC 50081-2
Immunity
ESDIEC 61000-4-2
Radiated, radio-frequency, electromagnetic fieldIEC 61000-4-3
Electrical fast transient/bustIEC 61000-4-4
SurgeIEC 61000-4-5
Conducted disturbancesIEC 61000-4-6
Power frequency magnetic fieldIEC 61000-4-8
Voltage dips and interruptionsIEC 61000-4-11
Generic Immunity Standard for Industrial EnvironmentEN 50082-2
Running Time  
Running Time  
Running Time  
Current Inputs (Each Channel)
Nominal Current 5 A ac
Nominal Current 5 A ac
Nominal Current 5 A ac
Nominal Current 5 A ac
Metering Range 0~6 A ac
Metering Range 0~6 A ac
Metering Range 0~6 A ac
Metering Range 0~6 A ac
Withstand 20Arms continuous100Arms for 1 second, non-recurring
Withstand 20Arms continuous100Arms for 1 second, non-recurring
Withstand 20Arms continuous100Arms for 1 second, non-recurring
Withstand 20Arms continuous100Arms for 1 second, non-recurring
Burden 0.05VA (typical) @5Arms
Burden 0.05VA (typical) @5Arms
Burden 0.05VA (typical) @5Arms
Burden 0.05VA (typical) @5Arms
Pickup Current 10Vac
Pickup Current 10Vac
Pickup Current 10Vac
Pickup Current 10Vac
Accuracy 0.005
Accuracy 0.005
Accuracy 0.005
Accuracy 0.005
Voltage Inputs (Each Channel)
Nominal Full Scale 400Vac L-N, 690Vac L-L (+20%)
Nominal Full Scale 400Vac L-N, 690Vac L-L (+20%)
Nominal Full Scale 400Vac L-N, 690Vac L-L (+20%)
Nominal Full Scale 400Vac L-N, 690Vac L-L (+20%)
Withstand 1500Vac continuous2500Vac, 50/60Hz for 1minute
Withstand 1500Vac continuous2500Vac, 50/60Hz for 1minute
Withstand 1500Vac continuous2500Vac, 50/60Hz for 1minute
Withstand 1500Vac continuous2500Vac, 50/60Hz for 1minute
Input Impedance 45Hz~65Hz
Input Impedance 45Hz~65Hz
Input Impedance 45Hz~65Hz
Input Impedance 45Hz~65Hz
Pickup Voltage 10Vac
Pickup Voltage 10Vac
Pickup Voltage 10Vac
Pickup Voltage 10Vac
Accuracy 0.005
Accuracy 0.005
Accuracy 0.005
Accuracy 0.005
Energy Accuracy (Acuvim-EL)
Active (according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Active (according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Active (according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Active (according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Reactive (according to IEC 62053-23) Class 2
Reactive (according to IEC 62053-23) Class 2
Reactive (according to IEC 62053-23) Class 2
Reactive (according to IEC 62053-23) Class 2
Harmonic Resolution
Metered Value 2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Metered Value 2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Metered Value 2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Metered Value 2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Universal AC or DC
Universal AC or DC
Universal AC or DC
Universal AC or DC
AC/DC Control Power
Operating Range 100~415Vac, 50/60Hz, 100~300Vdc
Operating Range 100~415Vac, 50/60Hz, 100~300Vdc
Operating Range 100~415Vac, 50/60Hz, 100~300Vdc
Operating Range 100~415Vac, 50/60Hz, 100~300Vdc
Burden 3W
Burden 3W
Burden 3W
Burden 3W
Withstand 3250Vac, 50/60Hz for 1 minute
Withstand 3250Vac, 50/60Hz for 1 minute
Withstand 3250Vac, 50/60Hz for 1 minute
Withstand 3250Vac, 50/60Hz for 1 minute
Low Voltage DC Control Power (Optional)
Operating Range 20~60Vdx
Operating Range 20~60Vdx
Operating Range 20~60Vdx
Operating Range 20~60Vdx
Burden 3W
Burden 3W
Burden 3W
Burden 3W
Digital Output (DO) (Photo-MOS)
Digital Output (DO) (Photo-MOS)
Digital Output (DO) (Photo-MOS)
Digital Output (DO) (Photo-MOS)
Voltage Range 0~250Vac/dc
Voltage Range 0~250Vac/dc
Voltage Range 0~250Vac/dc
Voltage Range 0~250Vac/dc
Load Current 100mA (Max)
Load Current 100mA (Max)
Load Current 100mA (Max)
Load Current 100mA (Max)
Output Frequency 25Hz, 50% Duty Ratio
Output Frequency 25Hz, 50% Duty Ratio
Output Frequency 25Hz, 50% Duty Ratio
Output Frequency 25Hz, 50% Duty Ratio
Isolation Voltage 2500V
Isolation Voltage 2500V
Isolation Voltage 2500V
Isolation Voltage 2500V
Digital Output (DI)
Input Voltage Range 20~250Vac/dc
Input Voltage Range 20~250Vac/dc
Input Voltage Range 20~250Vac/dc
Input Voltage Range 20~250Vac/dc
Input Current (Max) 2mA
Input Current (Max) 2mA
Input Current (Max) 2mA
Input Current (Max) 2mA
Start Voltage 15V
Start Voltage 15V
Start Voltage 15V
Start Voltage 15V
Stop Voltage 5V
Stop Voltage 5V
Stop Voltage 5V
Stop Voltage 5V
Pulse Frequency (Max) 100Hz, 50% Duty Ratio
Pulse Frequency (Max) 100Hz, 50% Duty Ratio
Pulse Frequency (Max) 100Hz, 50% Duty Ratio
Pulse Frequency (Max) 100Hz, 50% Duty Ratio
SOE Resolution 2ms
SOE Resolution 2ms
SOE Resolution 2ms
SOE Resolution 2ms
Operation Temperature -25°C to 70°C
Operation Temperature -25°C to 70°C
Operation Temperature -25°C to 70°C
Operation Temperature -25°C to 70°C
Storage Temperature -40°C to 85°C
Storage Temperature -40°C to 85°C
Storage Temperature -40°C to 85°C
Storage Temperature -40°C to 85°C
Relative Humidity 5% to 95% non-condensing
Relative Humidity 5% to 95% non-condensing
Relative Humidity 5% to 95% non-condensing
Relative Humidity 5% to 95% non-condensing
Pollution Degree 2
Pollution Degree 2
Pollution Degree 2
Pollution Degree 2
Product
USA UL 61010-1
USA UL 61010-1
USA UL 61010-1
USA UL 61010-1
Canada cUL 61010-1
Canada cUL 61010-1
Canada cUL 61010-1
Canada cUL 61010-1
Europe IEC 61010-1
Europe IEC 61010-1
Europe IEC 61010-1
Europe IEC 61010-1
Emission
Radiated/Conducted FCC Part 15 Subpart B, Class A
Radiated/Conducted FCC Part 15 Subpart B, Class A
Radiated/Conducted FCC Part 15 Subpart B, Class A
Radiated/Conducted FCC Part 15 Subpart B, Class A
Radiated/Conducted EN 55011
Radiated/Conducted EN 55011
Radiated/Conducted EN 55011
Radiated/Conducted EN 55011
Harmonic IEC 61000-3-2
Harmonic IEC 61000-3-2
Harmonic IEC 61000-3-2
Harmonic IEC 61000-3-2
Voltage Fluctuation IEC 50081-2
Voltage Fluctuation IEC 50081-2
Voltage Fluctuation IEC 50081-2
Voltage Fluctuation IEC 50081-2
Radio Interference IEC 50081-2
Radio Interference IEC 50081-2
Radio Interference IEC 50081-2
Radio Interference IEC 50081-2
Immunity
ESD IEC 61000-4-2
ESD IEC 61000-4-2
ESD IEC 61000-4-2
ESD IEC 61000-4-2
Radiated, radio-frequency, electromagnetic field IEC 61000-4-3
Radiated, radio-frequency, electromagnetic field IEC 61000-4-3
Radiated, radio-frequency, electromagnetic field IEC 61000-4-3
Radiated, radio-frequency, electromagnetic field IEC 61000-4-3
Electrical fast transient/bust IEC 61000-4-4
Electrical fast transient/bust IEC 61000-4-4
Electrical fast transient/bust IEC 61000-4-4
Electrical fast transient/bust IEC 61000-4-4
Surge IEC 61000-4-5
Surge IEC 61000-4-5
Surge IEC 61000-4-5
Surge IEC 61000-4-5
Conducted disturbances IEC 61000-4-6
Conducted disturbances IEC 61000-4-6
Conducted disturbances IEC 61000-4-6
Conducted disturbances IEC 61000-4-6
Power frequency magnetic field IEC 61000-4-8
Power frequency magnetic field IEC 61000-4-8
Power frequency magnetic field IEC 61000-4-8
Power frequency magnetic field IEC 61000-4-8
Voltage dips and interruptions IEC 61000-4-11
Voltage dips and interruptions IEC 61000-4-11
Voltage dips and interruptions IEC 61000-4-11
Voltage dips and interruptions IEC 61000-4-11
Generic Immunity Standard for Industrial Environment EN 50082-2
Generic Immunity Standard for Industrial Environment EN 50082-2
Generic Immunity Standard for Industrial Environment EN 50082-2
Generic Immunity Standard for Industrial Environment EN 50082-2

What's included with the Accuenergy ACUVIM-CL-D-60-5A-P1V4

  • Accuenergy ACUVIM-CL-D-60-5A-P1V4 Power/Energy Meter, LCD, RS485, 5 A input, 415 Vac/300 Vdc

Acuvim II Series Comparison

Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
Real Time Metering Phase Voltage U1, U2, U3
Real Time Metering Line Voltage U12, U23, U31
Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
Real Time Metering Power P1, P2, P3, Psum
Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Real Time Metering Apparent Power S1, S2, S3, Ssum
Real Time Metering Power Factor PF1, PF2, PF3, PF
Real Time Metering Load Nature L/C/R
Real Time Metering Frequency F Hz
Energy & Demand Energy Ep_imp, Ep_exp
Energy & Demand Reactive Energy Eq_imp, Eq_exp
Energy & Demand Apparent Energy Es
Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
Power Quality Voltage Unbalance U_unbl
Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Power Quality Voltage THD THD_V1, THD_V2, THD_V3
Power Quality Current THD THD_I1, THD_I2, THD_I3
Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
Statistics Max & Min of Voltage
Statistics Max & Min of Current
Hour Running Time Hour
Hour Load Running Time Hour
I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
I/O Alarm Output
Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

Acuvim II Series Comparison

Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
Real Time Metering Phase Voltage U1, U2, U3
Real Time Metering Line Voltage U12, U23, U31
Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
Real Time Metering Power P1, P2, P3, Psum
Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Real Time Metering Apparent Power S1, S2, S3, Ssum
Real Time Metering Power Factor PF1, PF2, PF3, PF
Real Time Metering Load Nature L/C/R
Real Time Metering Frequency F Hz
Energy & Demand Energy Ep_imp, Ep_exp
Energy & Demand Reactive Energy Eq_imp, Eq_exp
Energy & Demand Apparent Energy Es
Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
Power Quality Voltage Unbalance U_unbl
Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Power Quality Voltage THD THD_V1, THD_V2, THD_V3
Power Quality Current THD THD_I1, THD_I2, THD_I3
Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
Statistics Max & Min of Voltage
Statistics Max & Min of Current
Hour Running Time Hour
Hour Load Running Time Hour
I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
I/O Alarm Output
Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

Acuvim II Series Comparison

Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
Real Time Metering Phase Voltage U1, U2, U3
Real Time Metering Line Voltage U12, U23, U31
Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
Real Time Metering Power P1, P2, P3, Psum
Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Real Time Metering Apparent Power S1, S2, S3, Ssum
Real Time Metering Power Factor PF1, PF2, PF3, PF
Real Time Metering Load Nature L/C/R
Real Time Metering Frequency F Hz
Energy & Demand Energy Ep_imp, Ep_exp
Energy & Demand Reactive Energy Eq_imp, Eq_exp
Energy & Demand Apparent Energy Es
Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
Power Quality Voltage Unbalance U_unbl
Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Power Quality Voltage THD THD_V1, THD_V2, THD_V3
Power Quality Current THD THD_I1, THD_I2, THD_I3
Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
Statistics Max & Min of Voltage
Statistics Max & Min of Current
Hour Running Time Hour
Hour Load Running Time Hour
I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
I/O Alarm Output
Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

Acuvim II Series Comparison

Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
Real Time Metering Phase Voltage U1, U2, U3
Real Time Metering Line Voltage U12, U23, U31
Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
Real Time Metering Power P1, P2, P3, Psum
Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Real Time Metering Apparent Power S1, S2, S3, Ssum
Real Time Metering Power Factor PF1, PF2, PF3, PF
Real Time Metering Load Nature L/C/R
Real Time Metering Frequency F Hz
Energy & Demand Energy Ep_imp, Ep_exp
Energy & Demand Reactive Energy Eq_imp, Eq_exp
Energy & Demand Apparent Energy Es
Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
Power Quality Voltage Unbalance U_unbl
Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Power Quality Voltage THD THD_V1, THD_V2, THD_V3
Power Quality Current THD THD_I1, THD_I2, THD_I3
Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
Statistics Max & Min of Voltage
Statistics Max & Min of Current
Hour Running Time Hour
Hour Load Running Time Hour
I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
I/O Alarm Output
Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration Accuenergy meters.
  • Remote and real time monitoring of all meter parameters.
  • Dozens of meters can be connected to a single PC.
  • Multiple meters can be displayed and tiled in one window.
  • Real Time Data Logging.
  • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration Accuenergy meters.
  • Remote and real time monitoring of all meter parameters.
  • Dozens of meters can be connected to a single PC.
  • Multiple meters can be displayed and tiled in one window.
  • Real Time Data Logging.
  • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration Accuenergy meters.
  • Remote and real time monitoring of all meter parameters.
  • Dozens of meters can be connected to a single PC.
  • Multiple meters can be displayed and tiled in one window.
  • Real Time Data Logging.
  • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration Accuenergy meters.
  • Remote and real time monitoring of all meter parameters.
  • Dozens of meters can be connected to a single PC.
  • Multiple meters can be displayed and tiled in one window.
  • Real Time Data Logging.
  • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

Ask a question about Accuenergy ACUVIM-CL-D-60-5A-P1V4 Power/Energy Meter, LCD, RS485, 5 A input, 415 Vac/300 Vdc

Customer Reviews for the Accuenergy ACUVIM-CL-D-60-5A-P1V4

Accuenergy Acuvim CL-D-5A-P1 Offers

Panel metering is key to understanding energy consumption in homes, buildings, and facilities. The Accuenergy Acuvim CL includes a digital RS485 communication port running Modbus protocol. This model also includes 5A current input, 100 to 415V AC, 50/60Hz, 100 to 300V DC power supply, and integrated LCD display.

Features

  • True-RMS measurement parameters so that non-linear loads can be monitored
  • 4-quadrant energy measurement
  • Power quality analysis
  • Over/Under limit alarm
  • Max/Min statistics
  • Meter running time

Accuenergy ACUVIM-CL-D-60-5A-P1V4 Specifications

Parameters Acuvim-L Accuracy
Parameters Acuvim-L AccuracyAcuvim-EL/KL AccuracyResolutionRange
Parameters Acuvim-L Accuracy
Parameters Acuvim-L Accuracy
Parameters Acuvim-L Accuracy
Voltage 0.005
Voltage 0.5%0.5%0.1V20V~1000kV
Voltage 0.005
Voltage 0.005
Voltage 0.005
Current 0.005
Current 0.5%0.5%0.001A0~50000A
Current 0.005
Current 0.005
Current 0.005
Current Demand 0.005
Current Demand 0.5%0.5%0.001A0~50000A
Current Demand 0.005
Current Demand 0.005
Current Demand 0.005
Power 0.01
Power 1.0%0.5%1W-9999MW~9999MW
Power 0.01
Power 0.01
Power 0.01
Reactive Power 0.02
Reactive Power 2.0%0.5%1var-9999Mvar~9999Mvar
Reactive Power 0.02
Reactive Power 0.02
Reactive Power 0.02
Apparent Power 0.01
Apparent Power 1.0%0.5%0.001V0~9999MVA
Apparent Power 0.01
Apparent Power 0.01
Apparent Power 0.01
Power Demand 0.01
Power Demand 1.0%0.5%1W-9999MW~9999MW
Power Demand 0.01
Power Demand 0.01
Power Demand 0.01
Reactive Power Demand 0.02
Reactive Power Demand 2.0%0.5%1var-9999Mvar~9999Mvar
Reactive Power Demand 0.02
Reactive Power Demand 0.02
Reactive Power Demand 0.02
Apparent Power Demand 0.01
Apparent Power Demand 1.0%1VA1VA0~9999MVA
Apparent Power Demand 0.01
Apparent Power Demand 0.01
Apparent Power Demand 0.01
Power Factor 0.01
Power Factor 1.0%0.5%0.001-1.0~1.0
Power Factor 0.01
Power Factor 0.01
Power Factor 0.01
Frequency 0.002
Frequency 0.2%0.2%0.01Hz45.00~65.00Hz
Frequency 0.002
Frequency 0.002
Frequency 0.002
Energy 0.005
Energy 0.5%0.5%0.1kWh0~99999999.9kWh
Energy 0.005
Energy 0.005
Energy 0.005
Reactive Energy 0.02
Reactive Energy 2.0%0.5%0.1kvarh0~99999999.9kvarh
Reactive Energy 0.02
Reactive Energy 0.02
Reactive Energy 0.02
Apparent Energy 0.01
Apparent Energy 1.0%0.5%0.1VAh0~99999999.9kVAh
Apparent Energy 0.01
Apparent Energy 0.01
Apparent Energy 0.01
Harmonics 0.02
Harmonics 2.0%-0.01%0~100.0%
Harmonics 0.02
Harmonics 0.02
Harmonics 0.02
Running Time  
Running Time 0.1hrs0~999999999.9hrs
RS-485 (Option)
Modbus-RTU Protocol
2-wire connection, Half-duplex, Isolated
1200 to 38400 baud rate
Current Inputs (Each Channel)
Nominal Current5 A ac
Metering Range0~6 A ac
Withstand20Arms continuous100Arms for 1 second, non-recurring
Burden0.05VA (typical) @5Arms
Pickup Current10Vac
Accuracy0.5%
Voltage Inputs (Each Channel)
Nominal Full Scale400Vac L-N, 690Vac L-L (+20%)
Withstand1500Vac continuous2500Vac, 50/60Hz for 1minute
Input Impedance45Hz~65Hz
Pickup Voltage10Vac
Accuracy0.5%
Energy Accuracy (Acuvim-EL)
Active(according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Reactive(according to IEC 62053-23) Class 2
Harmonic Resolution
Metered Value2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
UniversalAC or DC
AC/DC Control Power
Operating Range100~415Vac, 50/60Hz, 100~300Vdc
Burden3W
Withstand3250Vac, 50/60Hz for 1 minute
Low Voltage DC Control Power (Optional)
Operating Range20~60Vdx
Burden3W
Digital Output (DO)(Photo-MOS)
Voltage Range0~250Vac/dc
Load Current100mA (Max)
Output Frequency25Hz, 50% Duty Ratio
Isolation Voltage2500V
Digital Output (DI)
Input Voltage Range20~250Vac/dc
Input Current (Max)2mA
Start Voltage15V
Stop Voltage5V
Pulse Frequency (Max)100Hz, 50% Duty Ratio
SOE Resolution2ms
Operation Temperature-25°C to 70°C
Storage Temperature-40°C to 85°C
Relative Humidity5% to 95% non-condensing
Pollution Degree2
Product
USAUL 61010-1
CanadacUL 61010-1
EuropeIEC 61010-1
Emission
Radiated/ConductedFCC Part 15 Subpart B, Class A
Radiated/ConductedEN 55011
HarmonicIEC 61000-3-2
Voltage FluctuationIEC 50081-2
Radio InterferenceIEC 50081-2
Immunity
ESDIEC 61000-4-2
Radiated, radio-frequency, electromagnetic fieldIEC 61000-4-3
Electrical fast transient/bustIEC 61000-4-4
SurgeIEC 61000-4-5
Conducted disturbancesIEC 61000-4-6
Power frequency magnetic fieldIEC 61000-4-8
Voltage dips and interruptionsIEC 61000-4-11
Generic Immunity Standard for Industrial EnvironmentEN 50082-2
Running Time  
Running Time  
Running Time  
Current Inputs (Each Channel)
Nominal Current 5 A ac
Nominal Current 5 A ac
Nominal Current 5 A ac
Nominal Current 5 A ac
Metering Range 0~6 A ac
Metering Range 0~6 A ac
Metering Range 0~6 A ac
Metering Range 0~6 A ac
Withstand 20Arms continuous100Arms for 1 second, non-recurring
Withstand 20Arms continuous100Arms for 1 second, non-recurring
Withstand 20Arms continuous100Arms for 1 second, non-recurring
Withstand 20Arms continuous100Arms for 1 second, non-recurring
Burden 0.05VA (typical) @5Arms
Burden 0.05VA (typical) @5Arms
Burden 0.05VA (typical) @5Arms
Burden 0.05VA (typical) @5Arms
Pickup Current 10Vac
Pickup Current 10Vac
Pickup Current 10Vac
Pickup Current 10Vac
Accuracy 0.005
Accuracy 0.005
Accuracy 0.005
Accuracy 0.005
Voltage Inputs (Each Channel)
Nominal Full Scale 400Vac L-N, 690Vac L-L (+20%)
Nominal Full Scale 400Vac L-N, 690Vac L-L (+20%)
Nominal Full Scale 400Vac L-N, 690Vac L-L (+20%)
Nominal Full Scale 400Vac L-N, 690Vac L-L (+20%)
Withstand 1500Vac continuous2500Vac, 50/60Hz for 1minute
Withstand 1500Vac continuous2500Vac, 50/60Hz for 1minute
Withstand 1500Vac continuous2500Vac, 50/60Hz for 1minute
Withstand 1500Vac continuous2500Vac, 50/60Hz for 1minute
Input Impedance 45Hz~65Hz
Input Impedance 45Hz~65Hz
Input Impedance 45Hz~65Hz
Input Impedance 45Hz~65Hz
Pickup Voltage 10Vac
Pickup Voltage 10Vac
Pickup Voltage 10Vac
Pickup Voltage 10Vac
Accuracy 0.005
Accuracy 0.005
Accuracy 0.005
Accuracy 0.005
Energy Accuracy (Acuvim-EL)
Active (according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Active (according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Active (according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Active (according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Reactive (according to IEC 62053-23) Class 2
Reactive (according to IEC 62053-23) Class 2
Reactive (according to IEC 62053-23) Class 2
Reactive (according to IEC 62053-23) Class 2
Harmonic Resolution
Metered Value 2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Metered Value 2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Metered Value 2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Metered Value 2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Universal AC or DC
Universal AC or DC
Universal AC or DC
Universal AC or DC
AC/DC Control Power
Operating Range 100~415Vac, 50/60Hz, 100~300Vdc
Operating Range 100~415Vac, 50/60Hz, 100~300Vdc
Operating Range 100~415Vac, 50/60Hz, 100~300Vdc
Operating Range 100~415Vac, 50/60Hz, 100~300Vdc
Burden 3W
Burden 3W
Burden 3W
Burden 3W
Withstand 3250Vac, 50/60Hz for 1 minute
Withstand 3250Vac, 50/60Hz for 1 minute
Withstand 3250Vac, 50/60Hz for 1 minute
Withstand 3250Vac, 50/60Hz for 1 minute
Low Voltage DC Control Power (Optional)
Operating Range 20~60Vdx
Operating Range 20~60Vdx
Operating Range 20~60Vdx
Operating Range 20~60Vdx
Burden 3W
Burden 3W
Burden 3W
Burden 3W
Digital Output (DO) (Photo-MOS)
Digital Output (DO) (Photo-MOS)
Digital Output (DO) (Photo-MOS)
Digital Output (DO) (Photo-MOS)
Voltage Range 0~250Vac/dc
Voltage Range 0~250Vac/dc
Voltage Range 0~250Vac/dc
Voltage Range 0~250Vac/dc
Load Current 100mA (Max)
Load Current 100mA (Max)
Load Current 100mA (Max)
Load Current 100mA (Max)
Output Frequency 25Hz, 50% Duty Ratio
Output Frequency 25Hz, 50% Duty Ratio
Output Frequency 25Hz, 50% Duty Ratio
Output Frequency 25Hz, 50% Duty Ratio
Isolation Voltage 2500V
Isolation Voltage 2500V
Isolation Voltage 2500V
Isolation Voltage 2500V
Digital Output (DI)
Input Voltage Range 20~250Vac/dc
Input Voltage Range 20~250Vac/dc
Input Voltage Range 20~250Vac/dc
Input Voltage Range 20~250Vac/dc
Input Current (Max) 2mA
Input Current (Max) 2mA
Input Current (Max) 2mA
Input Current (Max) 2mA
Start Voltage 15V
Start Voltage 15V
Start Voltage 15V
Start Voltage 15V
Stop Voltage 5V
Stop Voltage 5V
Stop Voltage 5V
Stop Voltage 5V
Pulse Frequency (Max) 100Hz, 50% Duty Ratio
Pulse Frequency (Max) 100Hz, 50% Duty Ratio
Pulse Frequency (Max) 100Hz, 50% Duty Ratio
Pulse Frequency (Max) 100Hz, 50% Duty Ratio
SOE Resolution 2ms
SOE Resolution 2ms
SOE Resolution 2ms
SOE Resolution 2ms
Operation Temperature -25°C to 70°C
Operation Temperature -25°C to 70°C
Operation Temperature -25°C to 70°C
Operation Temperature -25°C to 70°C
Storage Temperature -40°C to 85°C
Storage Temperature -40°C to 85°C
Storage Temperature -40°C to 85°C
Storage Temperature -40°C to 85°C
Relative Humidity 5% to 95% non-condensing
Relative Humidity 5% to 95% non-condensing
Relative Humidity 5% to 95% non-condensing
Relative Humidity 5% to 95% non-condensing
Pollution Degree 2
Pollution Degree 2
Pollution Degree 2
Pollution Degree 2
Product
USA UL 61010-1
USA UL 61010-1
USA UL 61010-1
USA UL 61010-1
Canada cUL 61010-1
Canada cUL 61010-1
Canada cUL 61010-1
Canada cUL 61010-1
Europe IEC 61010-1
Europe IEC 61010-1
Europe IEC 61010-1
Europe IEC 61010-1
Emission
Radiated/Conducted FCC Part 15 Subpart B, Class A
Radiated/Conducted FCC Part 15 Subpart B, Class A
Radiated/Conducted FCC Part 15 Subpart B, Class A
Radiated/Conducted FCC Part 15 Subpart B, Class A
Radiated/Conducted EN 55011
Radiated/Conducted EN 55011
Radiated/Conducted EN 55011
Radiated/Conducted EN 55011
Harmonic IEC 61000-3-2
Harmonic IEC 61000-3-2
Harmonic IEC 61000-3-2
Harmonic IEC 61000-3-2
Voltage Fluctuation IEC 50081-2
Voltage Fluctuation IEC 50081-2
Voltage Fluctuation IEC 50081-2
Voltage Fluctuation IEC 50081-2
Radio Interference IEC 50081-2
Radio Interference IEC 50081-2
Radio Interference IEC 50081-2
Radio Interference IEC 50081-2
Immunity
ESD IEC 61000-4-2
ESD IEC 61000-4-2
ESD IEC 61000-4-2
ESD IEC 61000-4-2
Radiated, radio-frequency, electromagnetic field IEC 61000-4-3
Radiated, radio-frequency, electromagnetic field IEC 61000-4-3
Radiated, radio-frequency, electromagnetic field IEC 61000-4-3
Radiated, radio-frequency, electromagnetic field IEC 61000-4-3
Electrical fast transient/bust IEC 61000-4-4
Electrical fast transient/bust IEC 61000-4-4
Electrical fast transient/bust IEC 61000-4-4
Electrical fast transient/bust IEC 61000-4-4
Surge IEC 61000-4-5
Surge IEC 61000-4-5
Surge IEC 61000-4-5
Surge IEC 61000-4-5
Conducted disturbances IEC 61000-4-6
Conducted disturbances IEC 61000-4-6
Conducted disturbances IEC 61000-4-6
Conducted disturbances IEC 61000-4-6
Power frequency magnetic field IEC 61000-4-8
Power frequency magnetic field IEC 61000-4-8
Power frequency magnetic field IEC 61000-4-8
Power frequency magnetic field IEC 61000-4-8
Voltage dips and interruptions IEC 61000-4-11
Voltage dips and interruptions IEC 61000-4-11
Voltage dips and interruptions IEC 61000-4-11
Voltage dips and interruptions IEC 61000-4-11
Generic Immunity Standard for Industrial Environment EN 50082-2
Generic Immunity Standard for Industrial Environment EN 50082-2
Generic Immunity Standard for Industrial Environment EN 50082-2
Generic Immunity Standard for Industrial Environment EN 50082-2

What's included with the Accuenergy ACUVIM-CL-D-60-5A-P1V4

  • Accuenergy ACUVIM-CL-D-60-5A-P1V4 Power/Energy Meter, LCD, RS485, 5 A input, 415 Vac/300 Vdc

Acuvim II Series Comparison

Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
Real Time Metering Phase Voltage U1, U2, U3
Real Time Metering Line Voltage U12, U23, U31
Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
Real Time Metering Power P1, P2, P3, Psum
Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Real Time Metering Apparent Power S1, S2, S3, Ssum
Real Time Metering Power Factor PF1, PF2, PF3, PF
Real Time Metering Load Nature L/C/R
Real Time Metering Frequency F Hz
Energy & Demand Energy Ep_imp, Ep_exp
Energy & Demand Reactive Energy Eq_imp, Eq_exp
Energy & Demand Apparent Energy Es
Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
Power Quality Voltage Unbalance U_unbl
Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Power Quality Voltage THD THD_V1, THD_V2, THD_V3
Power Quality Current THD THD_I1, THD_I2, THD_I3
Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
Statistics Max & Min of Voltage
Statistics Max & Min of Current
Hour Running Time Hour
Hour Load Running Time Hour
I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
I/O Alarm Output
Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

Acuvim II Series Comparison

Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
Real Time Metering Phase Voltage U1, U2, U3
Real Time Metering Line Voltage U12, U23, U31
Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
Real Time Metering Power P1, P2, P3, Psum
Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Real Time Metering Apparent Power S1, S2, S3, Ssum
Real Time Metering Power Factor PF1, PF2, PF3, PF
Real Time Metering Load Nature L/C/R
Real Time Metering Frequency F Hz
Energy & Demand Energy Ep_imp, Ep_exp
Energy & Demand Reactive Energy Eq_imp, Eq_exp
Energy & Demand Apparent Energy Es
Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
Power Quality Voltage Unbalance U_unbl
Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Power Quality Voltage THD THD_V1, THD_V2, THD_V3
Power Quality Current THD THD_I1, THD_I2, THD_I3
Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
Statistics Max & Min of Voltage
Statistics Max & Min of Current
Hour Running Time Hour
Hour Load Running Time Hour
I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
I/O Alarm Output
Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

Acuvim II Series Comparison

Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
Real Time Metering Phase Voltage U1, U2, U3
Real Time Metering Line Voltage U12, U23, U31
Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
Real Time Metering Power P1, P2, P3, Psum
Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Real Time Metering Apparent Power S1, S2, S3, Ssum
Real Time Metering Power Factor PF1, PF2, PF3, PF
Real Time Metering Load Nature L/C/R
Real Time Metering Frequency F Hz
Energy & Demand Energy Ep_imp, Ep_exp
Energy & Demand Reactive Energy Eq_imp, Eq_exp
Energy & Demand Apparent Energy Es
Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
Power Quality Voltage Unbalance U_unbl
Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Power Quality Voltage THD THD_V1, THD_V2, THD_V3
Power Quality Current THD THD_I1, THD_I2, THD_I3
Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
Statistics Max & Min of Voltage
Statistics Max & Min of Current
Hour Running Time Hour
Hour Load Running Time Hour
I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
I/O Alarm Output
Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

Acuvim II Series Comparison

Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
Real Time Metering Phase Voltage U1, U2, U3
Real Time Metering Line Voltage U12, U23, U31
Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
Real Time Metering Power P1, P2, P3, Psum
Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Real Time Metering Apparent Power S1, S2, S3, Ssum
Real Time Metering Power Factor PF1, PF2, PF3, PF
Real Time Metering Load Nature L/C/R
Real Time Metering Frequency F Hz
Energy & Demand Energy Ep_imp, Ep_exp
Energy & Demand Reactive Energy Eq_imp, Eq_exp
Energy & Demand Apparent Energy Es
Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
Power Quality Voltage Unbalance U_unbl
Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Power Quality Voltage THD THD_V1, THD_V2, THD_V3
Power Quality Current THD THD_I1, THD_I2, THD_I3
Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
Statistics Max & Min of Voltage
Statistics Max & Min of Current
Hour Running Time Hour
Hour Load Running Time Hour
I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
I/O Alarm Output
Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration Accuenergy meters.
  • Remote and real time monitoring of all meter parameters.
  • Dozens of meters can be connected to a single PC.
  • Multiple meters can be displayed and tiled in one window.
  • Real Time Data Logging.
  • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration Accuenergy meters.
  • Remote and real time monitoring of all meter parameters.
  • Dozens of meters can be connected to a single PC.
  • Multiple meters can be displayed and tiled in one window.
  • Real Time Data Logging.
  • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration Accuenergy meters.
  • Remote and real time monitoring of all meter parameters.
  • Dozens of meters can be connected to a single PC.
  • Multiple meters can be displayed and tiled in one window.
  • Real Time Data Logging.
  • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration Accuenergy meters.
  • Remote and real time monitoring of all meter parameters.
  • Dozens of meters can be connected to a single PC.
  • Multiple meters can be displayed and tiled in one window.
  • Real Time Data Logging.
  • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

Ask a question about Accuenergy ACUVIM-CL-D-60-5A-P1V4 Power/Energy Meter, LCD, RS485, 5 A input, 415 Vac/300 Vdc

Customer Reviews for the Accuenergy ACUVIM-CL-D-60-5A-P1V4

More Accuenergy Products