1.888.610.7664

sales@GlobalTestSupply.com

Chat Live

Customer Reviews

HOBO UX90-001M State/Pulse/Event/Runtime Data Logger, 512KB

Model: UX90-001M

HOBO UX90-001M State/Pulse/Event/Runtime Data Logger, 512KB-


Downloads: datasheet

HOBO UX90-001M State/Pulse/Event/Runtime Data Logger, 512KB

Model: UX90-001M

Records state changes, electronic pulses and mechanical or electrical contact closures from external sensing devices. Expanded 512KB memory version capable of over 346,795 measurements.

Records state changes, electronic pulses and mechanical or electrical contact closures from external sensing devices. Expanded 512KB memory version capable of over 346,795 measurements.

Your Price $121.00 USD
Availability 1 to 2 Weeks
Quantity

HOBO UX90-001M Offers

The award-winning HOBO UX90 Series is the industry's lowest-cost, most comprehensive family of "time-of-use" data loggers. The new toolbox suite includes LCD-display data loggers for measuring motor on/off status, electronic pulses, state changes, and occupancy and light-use patterns.

Features

  • One logger with 4 recording modes
  • Internal reed switch can be used to determine when a door or window is open or closed
  • Compatible with a wide range of external sensors
  • Ships with 2.5 mm input cable
  • Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis

Applications

  • Energy Performance Monitoring
  • Monitoring Building Efficiency
  • Energy Waste Monitoring in Schools
  • Turning Buildings Green

HOBO UX90-001M Specifications

Internal Sensor Maximum State, Event, Runtime Frequency 1 Hz
Preferred Switch State No Magnet Present (Normally Open)
External Contact Input Electronic Solid State Switch Closure or Logic Driven Voltage Output
External Input Range 0 to 3 V DC (USB Powered), 0 to 2.5 V DC (Battery Powered)
Maximum Pulses Frequency 50 Hz
External Input Maximum State, Event, Runtime Frequency 1 Hz
Pulse, Event Lockout Time 0 to 1 Second in 100 ms Steps
Solid State Switch Closure Input Low: < 10 Kohm
Input High: > 500 Kohm
Internal Weak Pull-Up: 100 Kohm
Input Impedance: Solid State Switch Closure: 100 Kohm Pull Up
Resolution Pulse: 1 Pulse
Runtime: 1 Second
State and Event: 1 State or Event
Logging Rate 1 Second to 18 Hours, 12 Minutes, 15 Seconds
Time Accuracy ±1 Minute Per Month at 25°C (77°F) (See Plot A)
Battery Life 1 Second to 18 Hours, 12 Minutes, 15 Seconds
Memory 512 KB (346,795 Measurements, Maximum)
Download Type USB 2.0 Interface
Download Time 10 Seconds for 128 KB; 30 Seconds for 512 KB
Click here for complete specifications on the HOBO UX90-001M

What's included with the HOBO UX90-001M

  • HOBO Data Logger UX90-001M
  • 2.5 mm Input Cable
  • Command™ Strip
  • Double-Sided Tape
  • Hook & Loop Strap
  • Magnet with 2 Screws

Accessories

Click on a category to view a selection of compatible accessories with the HOBO UX90-001M State/Pulse/Event/Runtime Data Logger, 512KB.

HOBO CSV-A8 AC Current Switch Sensor CSV-A8
For use with any state channel on UX-120-xxxx, U9-001 or U11-001 loggers. Installs around a current-carrying wire to provide a relay signal indications equipment on/off.
$92.00 USD

Learn More

HOBO T-WNB-3Y-208 WattNode kWh Transducer, Wye, 208/240 VAC T-WNB-3Y-208
Supports a 1-, 2-, or 3-phase Wye-connection of 208/240 VAC. Provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. Works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms.
$229.00 USD

Learn More

HOBO T-WNB-3D-480 WattNode kWh Transducer, Delta, 480 VAC T-WNB-3D-480
Supports a 3-phase Delta-connection of 480 VAC. Provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. Works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms.
$269.00 USD

Learn More

HOBO T-WNB-3D-240 WattNode kWh Transducer, Delta, 208/240 VAC T-WNB-3D-240
Supports a 3-phase Delta-connection of 208/240 VAC. Provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. Works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms.
$269.00 USD

Learn More

HOBO T-MAG-SCT-600 Split-Core AC Current Transformer, 600 A T-MAG-SCT-600
The Magnelab AC Current Transformer for use with HOBO H22, U30, and RX3000 Series Data Loggers. Used with S-FS-TRMSA or S-FS-TRMSA-D FlexSmart TRMS Module for True RMS AC amperage measurements of sinusoidal and non-sinusoidal waveforms.
$65.00 USD

Learn More

HOBO T-MAG-SCT-200 Split-Core AC Current Transformer, 200 A T-MAG-SCT-200
The Magnelab AC Current Transformer for use with HOBO H22, U30, and RX3000 Series Data Loggers. Used with S-FS-TRMSA or S-FS-TRMSA-D FlexSmart TRMS Module for True RMS AC amperage measurements of sinusoidal and non-sinusoidal waveforms.
$55.00 USD

Learn More

HOBO T-MAG-SCT-100 Split-Core AC Current Transformer, 100 A T-MAG-SCT-100
The Magnelab AC Current Transformer for use with HOBO H22, U30, and RX3000 Series Data Loggers. Used with S-FS-TRMSA or S-FS-TRMSA-D FlexSmart TRMS Module for True RMS AC amperage measurements of sinusoidal and non-sinusoidal waveforms.
$55.00 USD

Learn More

HOBO T-MAG-0400-75 Split-Core AC Current Transformer, 75 A T-MAG-0400-75
This small size 75A split-core AC current transformer (CT) is mounted around a current carrying wire to accurately measure AC amperage.
$35.00 USD

Learn More

HOBO T-MAG-0400-50 Split-Core AC Current Transformer, 50 A T-MAG-0400-50
This small size 50A split-core AC current transformer (CT) is mounted around a current carrying wire to accurately measure AC amperage.
$35.00 USD

Learn More

HOBO T-MAG-0400-20 Split-Core AC Current Transformer, 20 A T-MAG-0400-20
This small size 20A split-core AC current transformer (CT) is mounted around a current carrying wire to accurately measure AC amperage.
$35.00 USD

Learn More

HOBO T-MAG-0400-05 Split-Core AC Current Transformer, 5 A T-MAG-0400-05
This small size 5A split-core AC current transformer (CT) is mounted around a current carrying wire to accurately measure AC amperage.
$35.00 USD

Learn More

HOBO T-ACT-0750-250 Accu-CT Current Transformer, 250 A/333 mV T-ACT-0750-250
Revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.
$51.00 USD

Learn More

HOBO T-ACT-0750-100 Accu-CT Current Transformer, 100 A/333 mV T-ACT-0750-100
Revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.
$51.00 USD

Learn More

HOBO T-ACT-0750-050 Accu-CT Current Transformer, 50 A/333 mV T-ACT-0750-050
Revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.
$51.00 USD

Learn More

HOBO T-ACT-0750-020 Accu-CT Current Transformer, 20 A/333 mV T-ACT-0750-020
Revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.
$51.00 USD

Learn More

HOBO T-MINOL-130-NL Water Flow Meter, 0.25 to 22 gpm T-MINOL-130-NL
Measure cold and hot water flow rates with this compact, affordable water meter. TDesigned for deployment in apartments, assisted living communities, and other commercial buildings.
$207.00 USD

Learn More

HOBO A-WNB-LEADSET Voltage Input Lead Set A-WNB-LEADSET
A voltage lead set with alligator clips that is used to wire a WattNode terminal block connected to a WattNode kWh transducer and the voltage terminals in a circuit breaker panel.
$98.00 USD

Learn More

Customer Reviews for the HOBO UX90-001M

Ask a question about HOBO UX90-001M State/Pulse/Event/Runtime Data Logger, 512KB

comments powered by Disqus

HOBO UX90-001M Offers

The award-winning HOBO UX90 Series is the industry's lowest-cost, most comprehensive family of "time-of-use" data loggers. The new toolbox suite includes LCD-display data loggers for measuring motor on/off status, electronic pulses, state changes, and occupancy and light-use patterns.

Features

  • One logger with 4 recording modes
  • Internal reed switch can be used to determine when a door or window is open or closed
  • Compatible with a wide range of external sensors
  • Ships with 2.5 mm input cable
  • Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis

Applications

  • Energy Performance Monitoring
  • Monitoring Building Efficiency
  • Energy Waste Monitoring in Schools
  • Turning Buildings Green

HOBO UX90-001M Specifications

Internal Sensor Maximum State, Event, Runtime Frequency 1 Hz
Preferred Switch State No Magnet Present (Normally Open)
External Contact Input Electronic Solid State Switch Closure or Logic Driven Voltage Output
External Input Range 0 to 3 V DC (USB Powered), 0 to 2.5 V DC (Battery Powered)
Maximum Pulses Frequency 50 Hz
External Input Maximum State, Event, Runtime Frequency 1 Hz
Pulse, Event Lockout Time 0 to 1 Second in 100 ms Steps
Solid State Switch Closure Input Low: < 10 Kohm
Input High: > 500 Kohm
Internal Weak Pull-Up: 100 Kohm
Input Impedance: Solid State Switch Closure: 100 Kohm Pull Up
Resolution Pulse: 1 Pulse
Runtime: 1 Second
State and Event: 1 State or Event
Logging Rate 1 Second to 18 Hours, 12 Minutes, 15 Seconds
Time Accuracy ±1 Minute Per Month at 25°C (77°F) (See Plot A)
Battery Life 1 Second to 18 Hours, 12 Minutes, 15 Seconds
Memory 512 KB (346,795 Measurements, Maximum)
Download Type USB 2.0 Interface
Download Time 10 Seconds for 128 KB; 30 Seconds for 512 KB
Click here for complete specifications on the HOBO UX90-001M

What's included with the HOBO UX90-001M

  • HOBO Data Logger UX90-001M
  • 2.5 mm Input Cable
  • Command™ Strip
  • Double-Sided Tape
  • Hook & Loop Strap
  • Magnet with 2 Screws

Click on a category to view a selection of compatible accessories with the HOBO UX90-001M State/Pulse/Event/Runtime Data Logger, 512KB.

HOBO CSV-A8 AC Current Switch Sensor CSV-A8
For use with any state channel on UX-120-xxxx, U9-001 or U11-001 loggers. Installs around a current-carrying wire to provide a relay signal indications equipment on/off.
$92.00 USD

Learn More

HOBO T-WNB-3Y-208 WattNode kWh Transducer, Wye, 208/240 VAC T-WNB-3Y-208
Supports a 1-, 2-, or 3-phase Wye-connection of 208/240 VAC. Provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. Works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms.
$229.00 USD

Learn More

HOBO T-WNB-3D-480 WattNode kWh Transducer, Delta, 480 VAC T-WNB-3D-480
Supports a 3-phase Delta-connection of 480 VAC. Provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. Works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms.
$269.00 USD

Learn More

HOBO T-WNB-3D-240 WattNode kWh Transducer, Delta, 208/240 VAC T-WNB-3D-240
Supports a 3-phase Delta-connection of 208/240 VAC. Provides accurate measurement at low cost to meet your needs for sub-metering, net-metering, energy management, and performance contracting applications. Works with Magnelab AC Current Transformers and a Pulse Input Adapter to provide True RMS kilowatt hours of energy used, even for loads with non-sinusoidal waveforms.
$269.00 USD

Learn More

HOBO T-MAG-SCT-600 Split-Core AC Current Transformer, 600 A T-MAG-SCT-600
The Magnelab AC Current Transformer for use with HOBO H22, U30, and RX3000 Series Data Loggers. Used with S-FS-TRMSA or S-FS-TRMSA-D FlexSmart TRMS Module for True RMS AC amperage measurements of sinusoidal and non-sinusoidal waveforms.
$65.00 USD

Learn More

HOBO T-MAG-SCT-200 Split-Core AC Current Transformer, 200 A T-MAG-SCT-200
The Magnelab AC Current Transformer for use with HOBO H22, U30, and RX3000 Series Data Loggers. Used with S-FS-TRMSA or S-FS-TRMSA-D FlexSmart TRMS Module for True RMS AC amperage measurements of sinusoidal and non-sinusoidal waveforms.
$55.00 USD

Learn More

HOBO T-MAG-SCT-100 Split-Core AC Current Transformer, 100 A T-MAG-SCT-100
The Magnelab AC Current Transformer for use with HOBO H22, U30, and RX3000 Series Data Loggers. Used with S-FS-TRMSA or S-FS-TRMSA-D FlexSmart TRMS Module for True RMS AC amperage measurements of sinusoidal and non-sinusoidal waveforms.
$55.00 USD

Learn More

HOBO T-MAG-0400-75 Split-Core AC Current Transformer, 75 A T-MAG-0400-75
This small size 75A split-core AC current transformer (CT) is mounted around a current carrying wire to accurately measure AC amperage.
$35.00 USD

Learn More

HOBO T-MAG-0400-50 Split-Core AC Current Transformer, 50 A T-MAG-0400-50
This small size 50A split-core AC current transformer (CT) is mounted around a current carrying wire to accurately measure AC amperage.
$35.00 USD

Learn More

HOBO T-MAG-0400-20 Split-Core AC Current Transformer, 20 A T-MAG-0400-20
This small size 20A split-core AC current transformer (CT) is mounted around a current carrying wire to accurately measure AC amperage.
$35.00 USD

Learn More

HOBO T-MAG-0400-05 Split-Core AC Current Transformer, 5 A T-MAG-0400-05
This small size 5A split-core AC current transformer (CT) is mounted around a current carrying wire to accurately measure AC amperage.
$35.00 USD

Learn More

HOBO T-ACT-0750-250 Accu-CT Current Transformer, 250 A/333 mV T-ACT-0750-250
Revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.
$51.00 USD

Learn More

HOBO T-ACT-0750-100 Accu-CT Current Transformer, 100 A/333 mV T-ACT-0750-100
Revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.
$51.00 USD

Learn More

HOBO T-ACT-0750-050 Accu-CT Current Transformer, 50 A/333 mV T-ACT-0750-050
Revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.
$51.00 USD

Learn More

HOBO T-ACT-0750-020 Accu-CT Current Transformer, 20 A/333 mV T-ACT-0750-020
Revenue grade, split-core current transformer offers outstanding linearity and phase angle accuracy with a unique one-handed opening and closing mechanism.
$51.00 USD

Learn More

HOBO T-MINOL-130-NL Water Flow Meter, 0.25 to 22 gpm T-MINOL-130-NL
Measure cold and hot water flow rates with this compact, affordable water meter. TDesigned for deployment in apartments, assisted living communities, and other commercial buildings.
$207.00 USD

Learn More

HOBO A-WNB-LEADSET Voltage Input Lead Set A-WNB-LEADSET
A voltage lead set with alligator clips that is used to wire a WattNode terminal block connected to a WattNode kWh transducer and the voltage terminals in a circuit breaker panel.
$98.00 USD

Learn More

Ask a question about HOBO UX90-001M State/Pulse/Event/Runtime Data Logger, 512KB

Customer Reviews for the HOBO UX90-001M