ACCUENERGY ACUVIM-KL-D-60-5A-P1 Multifunction LCD Power Meter 100~415Vac, 50~60Hz, 100~300Vdc with COMM
The Accuenergy Acuvim L three-phase multifunction power and energy meter offers you reliability, with features like True-RMS measuring parameters and ANSI and IEC 0,2 Accuracy class. This model includes a 60Hz basic unit with communication, standard mount with LCD display, 5Amp current, and a 100~415Vac, 50~60Hz, 100~300Vdc power supply. With the Modbus TRU protocol, monitored data is easily accessible via a standard RS485 communication port. This energy meter also features 4 Quadrant Energy, Power Quality analysis, and Time of Use data. The Acuvim L is ideal for the metering of distribution feeder, generators, motors, transformers, and more: perfect for use with medium and low voltage systems in a variety of commercial, industrial, and utility applications.
Features:
- True-RMS measuring Parameters
- ANSI and IEC 0.2 Accuracy class
- Power Quality Analysis
- 4 Quadrant Energy
- Measure Individual Harmonics from 2nd to 15th (Acuvim-AL/BL/CL/DL)
- Module Design (Acuvim-DL/EL)
- TOU, 4 Tariffs, 12 Seasons, 14 Schedules (Acuvim-EL)
- Class leading Warranty
Applications:
- Metering of distribution feeders, transformers, generators, capacitor banks and motors
- Medium and low voltage systems
- Commercial, industrial, utility
- Power quality analysis
Specifications
Metering
| Parameters |
Acuvim-L Accuracy |
Acuvim-EL/KL Accuracy |
Resolution |
Range |
| Voltage |
0.5% |
0.5% |
0.1V |
20V~1000kV |
| Current |
0.5% |
0.5% |
0.001A |
0~50000A |
| Current Demand |
0.5% |
0.5% |
0.001A |
0~50000A |
| Power |
1.0% |
0.5% |
1W |
-9999MW~9999MW |
| Reactive Power |
2.0% |
0.5% |
1var |
-9999Mvar~9999Mvar |
| Apparent Power |
1.0% |
0.5% |
0.001V |
0~9999MVA |
| Power Demand |
1.0% |
0.5% |
1W |
-9999MW~9999MW |
| Reactive Power Demand |
2.0% |
0.5% |
1var |
-9999Mvar~9999Mvar |
| Apparent Power Demand |
1.0% |
1VA |
1VA |
0~9999MVA |
| Power Factor |
1.0% |
0.5% |
0.001 |
-1.0~1.0 |
| Frequency |
0.2% |
0.2% |
0.01Hz |
45.00~65.00Hz |
| Energy |
0.5% |
0.5% |
0.1kWh |
0~99999999.9kWh |
| Reactive Energy |
2.0% |
0.5% |
0.1kvarh |
0~99999999.9kvarh |
| Apparent Energy |
1.0% |
0.5% |
0.1VAh |
0~99999999.9kVAh |
| Harmonics |
2.0% |
- |
0.01% |
0~100.0% |
| Running Time |
|
|
0.1hrs |
0~999999999.9hrs |
Communication
| RS-485 (Option) |
| Modbus-RTU Protocol |
| 2-wire connection, Half-duplex, Isolated |
| 1200 to 38400 baud rate |
Input
| Current Inputs (Each Channel) |
| Nominal Current |
5 A ac |
| Metering Range |
0~6 A ac |
| Withstand |
20Arms continuous100Arms for 1 second, non-recurring |
| Burden |
0.05VA (typical) @5Arms |
| Pickup Current |
10Vac |
| Accuracy |
0.5% |
| Voltage Inputs (Each Channel) |
| Nominal Full Scale |
400Vac L-N, 690Vac L-L (+20%) |
| Withstand |
1500Vac continuous2500Vac, 50/60Hz for 1minute |
| Input Impedance |
45Hz~65Hz |
| Pickup Voltage |
10Vac |
| Accuracy |
0.5% |
| Energy Accuracy (Acuvim-EL) |
| Active |
(according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5 |
| Reactive |
(according to IEC 62053-23) Class 2 |
| Harmonic Resolution |
| Metered Value |
2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th) |
Control Power
| Universal |
AC or DC |
| AC/DC Control Power |
| Operating Range |
100~415Vac, 50/60Hz, 100~300Vdc |
| Burden |
3W |
| Withstand |
3250Vac, 50/60Hz for 1 minute |
| Low Voltage DC Control Power (Optional) |
| Operating Range |
20~60Vdx |
| Burden |
3W |
Digital Output Option
| Digital Output (DO) |
(Photo-MOS) |
| Voltage Range |
0~250Vac/dc |
| Load Current |
100mA (Max) |
| Output Frequency |
25Hz, 50% Duty Ratio |
| Isolation Voltage |
2500V |
Digital Input Option
| Digital Output (DI) |
| Input Voltage Range |
20~250Vac/dc |
| Input Current (Max) |
2mA |
| Start Voltage |
15V |
| Stop Voltage |
5V |
| Pulse Frequency (Max) |
100Hz, 50% Duty Ratio |
| SOE Resolution |
2ms |
Operating Environment
| Operation Temperature |
-25°C to 70°C |
| Storage Temperature |
-40°C to 85°C |
| Relative Humidity |
5% to 95% non-condensing |
| Pollution Degree |
2 |
Standard Compliance
| Product |
| USA |
UL 61010-1 |
| Canada |
cUL 61010-1 |
| Europe |
IEC 61010-1 |
| Emission |
| Radiated/Conducted |
FCC Part 15 Subpart B, Class A |
| Radiated/Conducted |
EN 55011 |
| Harmonic |
IEC 61000-3-2 |
| Voltage Fluctuation |
IEC 50081-2 |
| Radio Interference |
IEC 50081-2 |
| Immunity |
| ESD |
IEC 61000-4-2 |
| Radiated, radio-frequency, electromagnetic field |
IEC 61000-4-3 |
| Electrical fast transient/bust |
IEC 61000-4-4 |
| Surge |
IEC 61000-4-5 |
| Conducted disturbances |
IEC 61000-4-6 |
| Power frequency magnetic field |
IEC 61000-4-8 |
| Voltage dips and interruptions |
IEC 61000-4-11 |
| Generic Immunity Standard for Industrial Environment |
EN 50082-2 |
Click here for complete specifications on the Accuenergy Acuvim-KL-D-5A-P1
What's included with the Accuenergy Acuvim-KL-D-5A-P1
Acuvim-KL-D-5A-P1 Power Meter
Acuvim II Series Comparison
| Function |
Parameter |
Acuvim-AL |
Acuvim-BL |
Acuvim-CL |
Acuvim-DL |
Acuvim-EL |
Acuvim-KL |
| Real Time Metering |
Phase Voltage |
U1, U2, U3 |
|
|
|
|
|
|
| Real Time Metering |
Line Voltage |
U12, U23, U31 |
|
|
|
|
|
|
| Real Time Metering |
Current |
I1, I2, I3, In (Acuvim-KL no neutral current measurement) |
|
|
|
|
|
|
| Real Time Metering |
Power |
P1, P2, P3, Psum |
|
|
|
|
|
|
| Real Time Metering |
Reactive |
Power Q1, Q2, Q3, Qsum |
|
|
|
|
|
|
| Real Time Metering |
Apparent Power |
S1, S2, S3, Ssum |
|
|
|
|
|
|
| Real Time Metering |
Power Factor |
PF1, PF2, PF3, PF |
|
|
|
|
|
|
| Real Time Metering |
Load Nature |
L/C/R |
|
|
|
|
|
|
| Real Time Metering |
Frequency |
F Hz |
|
|
|
|
|
|
| Energy & Demand |
Energy |
Ep_imp, Ep_exp |
|
|
|
|
|
|
| Energy & Demand |
Reactive Energy |
Eq_imp, Eq_exp |
|
|
|
|
|
|
| Energy & Demand |
Apparent Energy |
Es |
|
|
|
|
|
|
| Energy & Demand |
Current Demand |
Dmd_I1,Dmd_I2 Dmd_I3 |
|
|
|
|
|
|
| Energy & Demand |
Power Demand |
Dmd_Psum, Dmd_Qsum, Dmd_Ssum |
|
|
|
|
|
|
| Time of Use |
Energy |
TOU, 4 Tariffs, 12 Seasons, 14 Schedules |
|
|
|
|
|
|
| Power Quality |
Voltage Unbalance |
U_unbl |
|
|
|
|
|
|
| Power Quality |
Current Unbalance |
I_unbl |
Trigger, Manual, DI change, Sag/Dips, Swell, Over Current |
|
|
|
| Power Quality |
Voltage THD |
THD_V1, THD_V2, THD_V3 |
|
|
|
|
|
|
| Power Quality |
Current THD |
THD_I1, THD_I2, THD_I3 |
|
|
|
|
|
|
| Power Quality |
Individual Harmonics |
2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th) |
|
|
|
|
|
|
| Statistics |
Max Current Demand |
Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max |
|
|
|
|
|
|
| Statistics |
Max Power Demand |
Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max |
|
|
|
|
|
|
| Statistics |
Max & Min of Voltage |
|
|
|
|
|
|
|
| Statistics |
Max & Min of Current |
|
|
|
|
|
|
|
| Hour |
Running Time |
Hour |
|
|
|
|
|
|
| Hour |
Load Running Time |
Hour |
|
|
|
|
|
|
| I/O |
Energy Pulse Output |
2 DO, configured as pulse output for kWh and kvarh, the
pulse rate and width can be set |
|
|
|
|
|
|
| I/O |
Alarm Output |
|
|
|
|
|
|
|
| Communication |
RS-485 |
Modbus®-RTU Protocol, 1200~38400 baud rate |
|
|
|
|
|
|
| Communication |
Second RS-485 |
Modbus®-RTU Protocol, 1200~38400 baud rate |
|
|
|
Opt |
Opt |
|
| Communication |
Profibus |
PROFIBUS-DP/V0 Protocol |
|
|
|
Opt |
Opt |
|
| Extension I/O |
4DI, 2DO |
SOE, Pulse Counter, Pulse output, Alarm output |
|
|
|
Opt |
Opt |
|
Acuview Software
As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.
Acuview Software Features
- Simple setup feature for fast deployment and configuration Accuenergy meters.
- Remote and real time monitoring of all meter parameters.
- Dozens of meters can be connected to a single PC.
- Multiple meters can be displayed and tiled in one window.
- Real Time Data Logging.
- Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
- All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
- SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.