Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A

Model: CT-SCM-0400-U

Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A-

Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A

Model: CT-SCM-0400-U

Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 400A amp rating.

Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 400A amp rating.

Your Price $70.00 USD
Availability 97 in Stock
Quantity

Add In-House Traceable Calibration to your CT-SCM-0400-U

Add In-House Traceable Calibration to your CT-SCM-0400-U


Dent CT-SCM-0400-U Offers

Features

  • Window size of 1.25"
  • Output is 333mV at rated current
  • Internal precision burden resistor across secondary
  • 8 ft twisted pair leads, terminated in ferrule for easy connection to all Dent meters
  • Typical accuracy is +/- 1% (measured from 10% to 130%)
  • Core blades are shrouded for protection during installation
  • Core is interleaved at joints for accuracy
  • cETLus Listed
  • CE Mark

Applications

  • Building automation
  • Tenant submetering
  • Performance verification
  • Energy management
  • New technology assessment

Dent CT-SCM-0400-U Specifications

Key Specifications
Window Size 1.25" (3.20 cm)
Current Range 8 to 520A AC
Output 333 mV at rated current
Ratio Error <1% at rated current (typical)
Phase Error <2° at rated current (typical)
Electrical
Output 333 mV at rated current
Wire Polarity White = Hi, positive (+)
Black = Low, negative (-)
Frequency Range 50 to 400 Hz
Mechanical
Case Material Epoxy encapsulated housing
Leads 2.7 m (8'), twisted pair, 20 AWG
Operating Temperature -4 to 131°F (-20 to 55°C)

What's included with the Dent CT-SCM-0400-U

  • Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A
  • Customer Reviews for the Dent CT-SCM-0400-U

    Ask a question about Dent CT-SCM-0400-U Medium Split Core Current Transformer, 400A

    comments powered by Disqus

    Dent CT-SCM-0400-U Offers

    Features

    • Window size of 1.25"
    • Output is 333mV at rated current
    • Internal precision burden resistor across secondary
    • 8 ft twisted pair leads, terminated in ferrule for easy connection to all Dent meters
    • Typical accuracy is +/- 1% (measured from 10% to 130%)
    • Core blades are shrouded for protection during installation
    • Core is interleaved at joints for accuracy
    • cETLus Listed
    • CE Mark

    Applications

    • Building automation
    • Tenant submetering
    • Performance verification
    • Energy management
    • New technology assessment

    Dent CT-SCM-0400-U Specifications

    Key Specifications
    Window Size 1.25" (3.20 cm)
    Current Range 8 to 520A AC
    Output 333 mV at rated current
    Ratio Error <1% at rated current (typical)
    Phase Error <2° at rated current (typical)
    Electrical
    Output 333 mV at rated current
    Wire Polarity White = Hi, positive (+)
    Black = Low, negative (-)
    Frequency Range 50 to 400 Hz
    Mechanical
    Case Material Epoxy encapsulated housing
    Leads 2.7 m (8'), twisted pair, 20 AWG
    Operating Temperature -4 to 131°F (-20 to 55°C)