Schneider PowerLogic DM6200 Digital Panel Meter



Schneider PowerLogic DM6200 Digital Panel Meter

Model: DM6200 | Order No: U017-0001

The PowerLogic DM6200 digital panel meter is capable of all basic measurements including Volts, Amps, Frequency, and Power Factor.

$175.00 USD

2 to 3 Weeks


DM6200 Panel Meter

PowerLogic® meters for entry-range applications

The PowerLogic DM6200 digital panel meter provides all the basic features needed to monitor an electrical panel affordably. Rugged enough to withstand industrial and commercial environments, this meter will help save on energy and installation costs, is easy to use, and adapts to various circuit requirements onsite. The PowerLogic DM6200 meter measures basic measurements (V, A, Hz & PF) and can be used for equipment monitoring, preventive maintenance scheduling, monitoring load locally, and replacing multiple analog meters.

The DM6200 features simple installation with a colour-keyed terminal board on the back that simplifies installation and helps ensure accurate wiring. The configurable load bar on the front display mimics an analog needle and monitors electrical usage locally so you can quickly gauge percentage of load on your equipment at a glance.

Applications:

Basic measurements (volts, amps, frequency, and power factor)

  • Equipment monitoring
  • Preventive maintenance scheduling
  • Monitoring electrical usage locally
  • Replacing multiple analog meters

Features:

  • Easy-to-read display
    The bright, alphanumeric 15mm-high LED display provides three lines for measurement values with four digits per line. This display auto-scales for Kilo, Mega and Giga values. Auto scrolling mode allows for easy reading.
  • Analog load bar
    The colour-coded analog load bar indicates the percentage of load through 12 LED segments.
  • Turbo Key access to information
    The Turbo Key gives access to the most commonly viewed parameters or enter setup mode with a single push of the button.
  • Quick and easy installation
    Setup is done through the front panel keys. Quick entry to setup during power up by TURBO key. Direct connection for metering voltage inputs up to 480 Vac L-L.
  • Colour-Keyed terminal board labeling
    The color-keyed label on the terminal board helps ensure accurate wiring.
  • Secure settings
    Safeguard access to setup parameters with unique password protection. A keypad lock lets you display a user-selected page by default.

Specs:

Metering and accuracy PowerLogic PM1200 PowerLogic DM6200
Volts Phase to phase average, per phase 1% of reading 1% of reading
Phase to neutral average, per phase 1% of reading 1% of reading
Amps Per phase and average 1% of reading 1% of reading
Neutral amps 1% of reading 1% of reading
Power factor Per phase and average 1% of reading 1% of reading
Power Active 1% of reading
Reactive 2% of reading
Apparent (per phase and total) 1% of reading
Energy Active 1.0 as per IEC 62053-21
Reactive (inductive and capacitive) 2.0 as per IEC 62053-23
Apparent
Energy Total
Import
Export
Demand Present demand and maximum demand (Amps, KW or KVA)
Time Remaining
Total harmonic distortion: % THD (volts and amps) per phase
Frequency
RPM
% Loading (amps)
ON hours
Number of interruptions
Run hours
Load bar: (% loading full scale)
Phase angles: amps per phase
Accuracy class 1.0 as per IEC62052-11 and IEC 62053-21
Power quality
Total harmonic distortion: % THD (volts and amps) per phase
% Unbalance (volts and amps)
Communications
RS-485 port with Modbus protocol

Ask a question about the Schneider PowerLogic DM6200 Digital Panel Meter:

comments powered by Disqus

Review the Schneider PowerLogic DM6200 Digital Panel Meter

" data-description="The PowerLogic DM6200 digital panel meter is capable of all basic measurements including Volts, Amps, Frequency, and Power Factor.">