AccuEnergy AcuCT Flex Series Flexible Rogowski Current Transformers
Downloads:
datasheet



AccuEnergy AcuCT Flex Series Flexible Rogowski Current Transformers

Model: AcuCT Flex Series

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

Help with Ordering

Select a Model

RCT 16-1000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$90.00 USD

1 to 2 Weeks


RCT 24-1000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$112.00 USD

2 to 3 Weeks


RCT 36-1000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$162.00 USD

1 to 2 Weeks


RCT 47-1000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$255.00 USD

2 to 3 Weeks


RCT 16-10000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$90.00 USD

2 to 3 Weeks


RCT 24-10000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$112.00 USD

2 to 3 Weeks


RCT 36-10000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$162.00 USD

2 to 3 Weeks


RCT 47-10000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$255.00 USD

2 to 3 Weeks


RCT 16-2500

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$90.00 USD

1 to 2 Weeks


RCT 24-2500

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$112.00 USD

2 to 3 Weeks


RCT 36-2500

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$162.00 USD

2 to 3 Weeks


RCT 47-2500

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$255.00 USD

2 to 3 Weeks


RCT 16-5000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$90.00 USD

2 to 3 Weeks


RCT 24-5000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$112.00 USD

2 to 3 Weeks


RCT 36-5000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$162.00 USD

2 to 3 Weeks


RCT 47-5000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$255.00 USD

2 to 3 Weeks


RCT 16-50000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$90.00 USD

2 to 3 Weeks


RCT 24-50000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$112.00 USD

2 to 3 Weeks


RCT 36-50000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$162.00 USD

2 to 3 Weeks


RCT 47-50000

Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.

$255.00 USD

2 to 3 Weeks


AccuEnergy AcuCT Flex Series Offers

High specification line of flexible AC current transformers for power metering, power quality and general use when space is limited.

Rope Style Form Factor
Allows Rope-like coil to be fit into any limited space from panel, bundle of wires or irregular size bus where regular CT cannot be used.

Wide Current Sensing
Measure current from 5A to 50,000A on a each standard coil.

Wide Frequency Response Range
Standard frequency response range 10Hz to 20KHz.

High Accuracy & Linearity
Across the entire range of measurement the accuracy is 0.5%.

4 Standard Length Selection
We offer four lengths of coil, 16", 24", 36" and 47".

Features

  • High accuracy for demanding applications
  • Wide frequency range means excellent choice for harmonics and power quality
  • Wide current input range from 5A - 50,000A AC

AccuEnergy AcuCT Flex Series Specifications

Current Input Ranges 5A to 1200A
12.5A to 3000A
25A to 6000A
50A to 12000A
250A to 50000A
Window Sizes 106mm (4.17")
178mm (7.01")
271mm (10.67")
369mm (14.53")
Lengths of Coil 400mm (15.75")
600mm (23.62")
900mm (35.43")
1200mm (47.24")
Frequency Range 20Hz to 5kHz
Accuracy 0.5% at any point
Lead White-Positive, Brown-Negative, Bare-Shield; 24AWG
Operating Temperature -20 to 70°C
Material Orange Thermoplastic Rubber, Flame Retardant UL 94V-0 Rated
Click here for complete specifications on the Accuenergy AcuCT Flex Series

Ask a question about the AccuEnergy AcuCT Flex Series Flexible Rogowski Current Transformers:

comments powered by Disqus

Review the AccuEnergy AcuCT Flex Series Flexible Rogowski Current Transformers

" data-description="Designed for use where regular solid or split core current transformers cannot fit, and is ideal for power quality monitoring such as harmonics. Advantages of the Rogowski coil include high accuracy and a wide measurement and frequency range with no additional integrator or power supply needed.">