Home » IMS 3000R Series Meter with Outdoor Weatherproof Enclosure
IMS 3000R Series Meter with Outdoor Weatherproof Enclosure




*Available Summer 2010
The IMS 3000 Series Meter with outdoor plastic enclosure (NEMA 4X rated) offers more features and functionality than anything ever manufactured by IMS Meters. This revenue-grade meter can be built with a 1, 2 or 3-Phase configuration.
Incorporating the latest technology and our decades of energy meter design and manufacturing experience, these products will be suitable for a number of energy monitoring, management, and billing applications. As always, these products come with the IMS ten-year warranty.
The IMS 3000 Series measures kWh, Demand, Instantaneous power, volts, amps, watts, VAR, and VA per phase. These meters conform to all applicable standards of ANSI C12.1 and ANSI C12.20 (0.5) Codes for Electricity Metering. Equipped with an RS-485 two-way serial data port that supports optional IP module, Modbus and BACnet protocols, and thus can be tied in to most building and energy management systems. It provides time-stamped and data logged meter readings, which are displayed at the meter and can be accessed remotely via the serial port. An onboard real time clock is battery backed up in the event of a power failure, and can be synchronized remotely.
IMS recommends solid core transformers (CT’s) for revenue grade billing. Our 100A & 200A color coded CT’s (to the right) assist with correct installation by indicating phase monitored. Split core CT’s (to the right) are also available upon request for applications where power cannot interrupted during installation. Our 100A, 200A, and 400A split core models offer a 1% accuracy.
The IMS 3000 Series Meter with outdoor plastic enclosure (NEMA 4X rated) offers more features and functionality than anything ever manufactured by IMS Meters. This revenue-grade meter can be built with a 1, 2 or 3-Phase configuration.
Incorporating the latest technology and our decades of energy meter design and manufacturing experience, these products will be suitable for a number of energy monitoring, management, and billing applications. As always, these products come with the IMS ten-year warranty.
The IMS 3000 Series measures kWh, Demand, Instantaneous power, volts, amps, watts, VAR, and VA per phase. These meters conform to all applicable standards of ANSI C12.1 and ANSI C12.20 (0.5) Codes for Electricity Metering. Equipped with an RS-485 two-way serial data port that supports optional IP module, Modbus and BACnet protocols, and thus can be tied in to most building and energy management systems. It provides time-stamped and data logged meter readings, which are displayed at the meter and can be accessed remotely via the serial port. An onboard real time clock is battery backed up in the event of a power failure, and can be synchronized remotely.
IMS recommends solid core transformers (CT’s) for revenue grade billing. Our 100A & 200A color coded CT’s (to the right) assist with correct installation by indicating phase monitored. Split core CT’s (to the right) are also available upon request for applications where power cannot interrupted during installation. Our 100A, 200A, and 400A split core models offer a 1% accuracy.
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
- kWh, maximum demand, and instantaneous power on LCD display and over Modbus serial port
- NEMA 4X Rated enclosure
- Same meter for 3PH 3W Delta or 3PH 4W Y configurations, 208V or 480V
- Revenue-grade accuracy with solid-core CTs, or easy to install split core CTs
- Wide operating range with automatic temperature compensation for maximum accuracy (0.5% error max under all conditions with IMS solid core CTs)
- Large custom LCD display with scroll button
- 12VDC mechanical counter output
- Auxiliary 12VDC output @ 200mA for powering wireless AMR devices
- Two isolated pulse outputs (kWh & 10wh)
- Low voltage detection
- Reverse energy indicators (per phase) on display to ensure correct meter installation
- kWh, Max. Demand (kW), Frequency (Hz)
- Volts, Amps, Watts, VA, and PF per phase
- Time of Use Metering: Built-in data logger stores kWh, Volts, Amps, and Watts, with date & time stamp from real time clock (65 days of data storage @ 15 minute intervals)
- Volts, Amps, Watts, VA, and PF per phase on display
- Bidirectional Metering (kWh; bidirectional Demand upon request)
- BACnet interface
- Ethernet interface (IP addressable)
- Battery backup for real time clock
For 1 or 2 phase Series 3000 electrical
specifications:
1 Accuracy based on IMS solid core transformers (included), with 100 mA secondary output. Meter input burden resistance at 2 Ohms.
2 Pollution Degree 2: Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.
For 3 phase Series 3000 electrical specifications:
1 Accuracy based on IMS solid core transformers (included), with 100 mA secondary output. Meter input burden resistance at 2 Ohms.
2 Pollution Degree 2: Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.
| Input Configurations | 1 Phase, 2 Wire (120/277 V) | 1 or 2 Phase, 2 Wire (120/208, 120/240 or 277/480 V) |
| Supply Voltage
Range (Line to Neutral) | 102-138 VAC 235-320 VAC | 102-138 VAC 235-320 VAC |
| Maximum Input
Power | 7 VA | 7 VA |
| Maximum Rated
Current * | Primary:
Operating Current + 10% Secondary: 0.12 A | Primary:
Operating Current + 10% Secondary: 0.12 A |
| Line Frequency | 50-60 Hz | 50-60 Hz |
| Power Factor Range | 0.5 to 1.0 leading or lagging | 0.5 to 1.0 leading or lagging |
| Accuracy1 | +/- 0.5% of registration @ 1.0pf, 1% to 100% of
rated current +/- 0.75% of registration @0.5pf, 1% to 100% of rated current | +/- 0.5% of registration @ 1.0pf, 1% to 100% of
rated current +/- 0.75% of registration @0.5pf, 1% to 100% of rated current |
| Meter Operating
Temperature | -30 to +60 degrees C | -30 to +60 degrees C |
| Display Operating Temperature | -20 to +50
degrees C | -20 to +50 degrees C |
| Rated
Pollution Degree2 | 2 | 2 |
| Rated Relative Humidity | 80% | 80% |
| Terminal Blocks: Voltage Terminal: Molex 386344304 or equiv. CT Terminal: Camden CTB9308 & CTB9208 or equiv. I/O Terminal: Dinkle/International Connector EK508-11P or equiv. | 14-18 AWG 12 in-lb of torque maximum 14-18 AWG 4.4 in-lb of torque maximum 13-18 AWG 4.4 in-lb of torque maximum | 14-18 AWG 12 in-lb of torque maximum 14-18 AWG 4.4 in-lb of torque maximum 13-18 AWG 4.4 in-lb of torque maximum |
1 Accuracy based on IMS solid core transformers (included), with 100 mA secondary output. Meter input burden resistance at 2 Ohms.
2 Pollution Degree 2: Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.
For 3 phase Series 3000 electrical specifications:
| Input
Configurations | 3 Phase, 3 Wire
Delta (208, 480, 600 V) | 3 Phase, 4
Wire Wye (120/208, 277/480 or 347/600 V) |
| Supply Voltage Range | Line to Line: 177-239 VAC 408-552 VAC 510-690 VAC | Line to Neutral: 102-138 VAC 235-320 VAC 295-400 VAC |
| Maximum Input
Power | 7 VA | 7 VA |
| Maximum Rated
Current * | Primary:
Operating Current + 10% Secondary: 0.12 A | Primary:
Operating Current + 10% Secondary: 0.12 A |
| Line Frequency | 50-60 Hz | 50-60 Hz |
| Power Factor Range | 0.5 to 1.0 leading or lagging | 0.5 to 1.0 leading or lagging |
| Accuracy1 | +/- 0.5% of registration @ 1.0pf, 1% to 100% of
rated current +/- 0.75% of registration @0.5pf, 1% to 100% of rated current | +/- 0.5% of registration @ 1.0pf, 1% to 100% of
rated current +/- 0.75% of registration @0.5pf, 1% to 100% of rated current |
| Meter Operating
Temperature | -30 to +60 degrees C | -30 to +60 degrees C |
| Display Operating Temperature | -20 to +50
degrees C | -20 to +50 degrees C |
| Rated
Pollution Degree2 | 2 | 2 |
| Rated Relative Humidity | 80% | 80% |
| Terminal Blocks: | Same as table
above. | Same
as table above. |
1 Accuracy based on IMS solid core transformers (included), with 100 mA secondary output. Meter input burden resistance at 2 Ohms.