Home » Acuvim IIR Power & Energy Meter with Datalogging
Acuvim IIR Power & Energy Meter with Datalogging





Acuvim IIR power meter is a revenue grade power meter with on-board datalogging that can be used to meter & monitor power consumption at electrical panels and energy consuming devices or systems. It offers a wide array of communications options and standard MODBUS communications via a built-in RS485 port. This meter can also be used in conjunction with the free Acuview PC software for remote communications and control.
Since the Acuvim IIR is 0.2% accuracy and meets the ANSI C12.20 standard for revenue grade meters so it can also be used for tenant sub-metering applications.
With so many features for the low price, the Acuvim IIR offers unbeatable value.
Measurements
Acuvim IIR power meters can be used on any single or three phase electrical system up to 600V AC. Measurement parameters include volts, amps, frequency, power (apparent, active, reactive) & energy, power factor, peak demand, run time, THD and individual harmonics on both voltage and current to the 63rd harmonic.
In addition, Acuvim IIR power meters support four quadrant energy, showing total power, import, export and net power with 0.2% accuracy.
Communications
There are four optional field upgradeable plug-in communications modules for the Acuvim IIR power meter. These modules include analog I/O ports, digital I/O ports, Ethernet, or relays.
The table below shows which input/outputs are available on which modules:
In addition, there are three communication modules for the Acuvim IIR - AXM-PROFI for PROFIBUS communication, AXM-NET for ethernet communications and the AXM-RS485 for an additional MODBUS RS485 communication port.
The Ethernet communications module enables MODBUS communication over Ethernet, plus offers configurable email alarms/alerts and a built-in web server for real-time data access through an Internet browser.
A total of 3 external modules can be stacked and used together with each Acuvim IIR meter. All modules are self-detecting and can be configured through the display or through Acuview Software.
Software
Acuvim IIR models are compatible with Acuview Software and communicate via MODBUS communications protocol using either the built-in RS485 serial port or the optional AXM-NET Ethernet Module. Acuview Software enables remote meter access for real-time monitoring and local PC-based datalogging. You can download a demo copy of Acuview software - instructions for installing and using the demo software are in this PDF document.
Watch a video demo of Acuview software.
Acuview software is a PC-based data logging and reporting software designed to extend the capabilities of any Acuvim power meter that uses RS485 or Ethernet communications. Best of all, the software is completely free!
Form Factor
This power meter is packaged in a compact housing that fits a standard 96×96 DIN or 4’’ ANSI Round coutout. The Acuvim IIR display is a large character graphical LCD screen with white back light.
Warranty & Approvals
Acuvim IIR meters are UL/ULc approved for use throughout North America and come with a 5 Year manufacturer's warranty.
Since the Acuvim IIR is 0.2% accuracy and meets the ANSI C12.20 standard for revenue grade meters so it can also be used for tenant sub-metering applications.
With so many features for the low price, the Acuvim IIR offers unbeatable value.
Measurements
Acuvim IIR power meters can be used on any single or three phase electrical system up to 600V AC. Measurement parameters include volts, amps, frequency, power (apparent, active, reactive) & energy, power factor, peak demand, run time, THD and individual harmonics on both voltage and current to the 63rd harmonic.
In addition, Acuvim IIR power meters support four quadrant energy, showing total power, import, export and net power with 0.2% accuracy.
Communications
There are four optional field upgradeable plug-in communications modules for the Acuvim IIR power meter. These modules include analog I/O ports, digital I/O ports, Ethernet, or relays.
The table below shows which input/outputs are available on which modules:
| Module | Digital In (DI) | Power for DI | Digital Out (DO) | Relay Out (RO) | Analog In (AI) | Analog Out (AO) |
| AXM-IO1 | 6 | 1 | 2 | |||
| AXM-IO2 | 4 | 2 | 2 | |||
| AXM-IO3 | 4 | 2 | 2 |
In addition, there are three communication modules for the Acuvim IIR - AXM-PROFI for PROFIBUS communication, AXM-NET for ethernet communications and the AXM-RS485 for an additional MODBUS RS485 communication port.
The Ethernet communications module enables MODBUS communication over Ethernet, plus offers configurable email alarms/alerts and a built-in web server for real-time data access through an Internet browser.
A total of 3 external modules can be stacked and used together with each Acuvim IIR meter. All modules are self-detecting and can be configured through the display or through Acuview Software.
Software
Acuvim IIR models are compatible with Acuview Software and communicate via MODBUS communications protocol using either the built-in RS485 serial port or the optional AXM-NET Ethernet Module. Acuview Software enables remote meter access for real-time monitoring and local PC-based datalogging. You can download a demo copy of Acuview software - instructions for installing and using the demo software are in this PDF document.
Watch a video demo of Acuview software.
Acuview software is a PC-based data logging and reporting software designed to extend the capabilities of any Acuvim power meter that uses RS485 or Ethernet communications. Best of all, the software is completely free!
Form Factor
This power meter is packaged in a compact housing that fits a standard 96×96 DIN or 4’’ ANSI Round coutout. The Acuvim IIR display is a large character graphical LCD screen with white back light.
Warranty & Approvals
Acuvim IIR meters are UL/ULc approved for use throughout North America and come with a 5 Year manufacturer's warranty.
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
Metering
▪ Voltage V1, V2, V3, Vlnavg, V12, V23, V31, Vllavg
▪ Current I1, I2, I3, In, Iavg
▪ Power P1, P2, P3, Psum
▪ Reactive Power Q1, Q2, Q3, Qsum
▪ Apparent Power S1, S2, S3, Ssum
▪ Frequency F
▪ Power Factor PF1, PF2, PF3, PF
▪ Energy Ep_imp, Ep_exp, Ep_total, Ep_net
▪ Reactive Energy Eq_imp, Eq_exp, Eq_total, Eq_net
▪ Apparent Energy Es
▪ Demand Dmd_P, Dmd_Q, Dmd_S
Monitoring
▪ Power Quality
▪ Voltage Harmonics 2nd to 63rd and THD
▪ Current Harmonics 2nd to 63rd and THD
▪ Voltage Crest Factor
▪ THFF (TIF)
▪ Current K Factor
▪ Voltage Unbalance Factor U_unbl
▪ Current Unbalance Factor I_unbl
▪ Max/Min Statistics with Time Stamps
Alarms
Limits can be set for up to 16 indicated parameters and can be set with a specified time interval. If any input of the indicated parameters is over or under its setting limit and persists over the specified time interval, the event will be recorded with time stamps and trigger the Alarm DO output. The 16 indicated parameters can be selected from any of the 44 parameters available.I/O option module
The E-module® technique was adopted for its flexibility and easy expansion of the I/O function of Acuvim II. A maximum of 3 modules can be used for one meter. Digital input, digital output, pulse output, relay output, analog input and analog output are provided by I/O option module.Communication
RS485, Industry standard Modbus™ protocolModule Option: Ethernet module, Profbus-DP module
Dual communication ports.
Display
Clear and large character LCD Screen display with white back lightWide environmental temperature endurance
Display Load percentage, 4 quadrants power and load nature
Outline
Small Size 96X96 DIN or 4" ANSI RoundData Logging
4MB of on-board data logging memoryRemote datalogging can also be achieved using the free Acuview software with either MODBUS RS485 or MODBUS over Ethernet with the optional AXM-NET Ethernet module.
| Acuvim II Series Meters | |||||||
| Category | Item | Parameters | Acuvim II | Acuvim IIR | Acuvim IIE | Acuvim IIW | |
| Metering | Real Time Metering | Phase Voltage | V1, V2, V3, Vlnavg | ● | ● | ● | ● |
| Metering | Real Time Metering | Line Voltage | V12, V23, V31, Vllavg | ● | ● | ● | ● |
| Metering | Real Time Metering | Current | I1, I2, I3, In, Iavg | ● | ● | ● | ● |
| Metering | Real Time Metering | Power | P1, P2, P3, Psum | ● | ● | ● | ● |
| Metering | Real Time Metering | Reactive Power | Q1, Q2, Q3, Qsum | ● | ● | ● | ● |
| Metering | Real Time Metering | Apparent Power | S1, S2, S3, Ssum | ● | ● | ● | ● |
| Metering | Real Time Metering | Power Factor | PF1, PF2, PF3, PF | ● | ● | ● | ● |
| Metering | Real Time Metering | Frequency | F | ● | ● | ● | ● |
| Metering | Real Time Metering | Load Features | Load Features | ● | ● | ● | ● |
| Metering | Real Time Metering | Four Quadrant Powers | Four Quadrant Powers | ● | ● | ● | ● |
| Metering | Energy & Demand | Energy | Ep_imp, Ep_exp, Ep_total, Ep_net | ● | ● | ● | ● |
| Metering | Energy & Demand | Reactive Energy | Eq_imp, Eq_exp, Eq_total, Eq_net | ● | ● | ● | ● |
| Metering | Energy & Demand | Apparent Energy | Es | ● | ● | ● | ● |
| Metering | Energy & Demand | Demand | Dmd_P, Dmd_Q, Dmd_S, Dmd_I1, Dmd_I2, Dmd_I3 | ● | ● | ● | ● |
| TOU | Time of Use | Energy/max demand | TOU, 4 Tariffs, 12 Seasons, 14 Schedules | ● | |||
| TOU | Daylight Savings Time | Two formats adjust | Month/Day/Hour/Minute Month/Week/First few weeks/Hour/Minute | ● | |||
| Monitoring | Waveform Capture | voltage and current Waveform | Trigger, Manual, DI change, Sag/Dips, Swell, Over Current | ● | |||
| Monitoring | Power Quality | Voltage Unbalance Factor | U_unbl | ● | ● | ● | ● |
| Monitoring | Power Quality | Current Unbalance Factor | I_unbl | ● | ● | ● | ● |
| Monitoring | Power Quality | Voltage THD | THD_V1,THD_V2,THD_V3, THD_Vavg | ● | ● | ● | ● |
| Monitoring | Power Quality | Current THD | THD_I1, THD_I2, THD_I, THD_Iavg | ● | ● | ● | ● |
| Monitoring | Power Quality | Individual Harmonics | Harmonics 2nd to 63rd (31st for Acuvim II) | ● | ● | ● | ● |
| Monitoring | Power Quality | Voltage Crest Factor | Crest Factor | ● | ● | ● | ● |
| Monitoring | Power Quality | TIF | THFF | ● | ● | ● | ● |
| Monitoring | Power Quality | Current K factor | K Factor | ● | ● | ● | ● |
| Monitoring | Statistics | MAX with Time Stamp MIN with Time Stamp | Each phase of V & l; Total of P, Q, S, PF & F; Demad of P,Q & S; Each phase THD of V & I; Unbalnce factor of V & I | ● | ● | ● | ● |
| Others | Alarm | Over/Under Limit Alarm | V, I, P, Q, S, PF, V_THD & I_THD each phase and total or average; Unbalance factor of V & I; load type; Analog Input of each channel | ● | ● | ● | ● |
| Others | Power Quality Event logging | SAG/DIPS,SWELL | Voltage | ● | |||
| Others | Data Logging | Data Logging 1 Data Logging 2 Data Logging 3 | F, V1/2/3/lnavg, V12/23/13/lavg, I1/2/3/n/avg, P1/2/3/sum,Q1/2/3/sum, S1/2/3/sum, PF1/2/3, PF, U_unbl, I_unbl, LoadType, Ep_imp, Ep_exp, Ep_total, Ep_net, Eq_imp, Eq_exp, Eq_total, Eq_net, Es, THD_V1/2/3/avg, THD_I1/2/3/avg, Harmonics2nd to 63rd, Crest Factor, THFF, K Factor, sequence and phaseangles, DI counter, AI, AO, Dmd P/Q/S, Dmd I1/2/3 | ● | ● | ● | |
| Others | Onboard memory size | Memory | Bytes | - | 4MB | 4MB | 4MB |
| Others | Communication | RS485 Port, Half Duplex,Optical Isolated | Modbus®-RTU Protocol | ● | ● | ● | ● |
| Others | Time | Real Time Clock | Year, Month, Date, Hour, Minute, Second | ● | ● | ● | ● |
| Option Module | I/O Option | Switch Status (DI) | Digital Input (Wet) | Option | Option | Option | Option |
| Option Module | I/O Option | Power Supply for DI | 24 Vdc | Option | Option | Option | Option |
| Option Module | I/O Option | Relay Output (RO) | NO, Form A | Option | Option | Option | Option |
| Option Module | I/O Option | Digital Output (DO) | Photo-MOS | Option | Option | Option | Option |
| Option Module | I/O Option | Pulse Output (PO) | By using DO | Option | Option | Option | Option |
| Option Module | I/O Option | Analog Input (AI) | 0(4)~20mA, 0(1)~5V | Option | Option | Option | Option |
| Option Module | I/O Option | Analog Output (AO) | 0(4)~20mA, 0(1)~5V | Option | Option | Option | Option |
| Option Module | Communication | Ethernet | 10M/100M, Modbus-TCP, HTTP Webpage, Email | Option | Option | Option | Option |
| Option Module | Communication | Profibus-DP | Profibus-DP/V0 | Option | Option | Option | Option |
| Option Module | Communication | RS485 Module | Additional Modbus RTU | Option | Option | Option | Option |
Acuvim
IIR models are compatible with Acuview Software and communicate via
MODBUS communications protocol using either the built-in RS485 serial
port or the optional AXM-NET Ethernet Module. Acuview Software enables
remote meter access for real-time monitoring and local PC-based
datalogging. You can download a demo copy of Acuview software - instructions for installing and using the demo software are in this PDF document.
Watch a video demo of Acuview software.

Acuview software is a PC-based data logging and reporting software designed to extend the capabilities of any Acuvim power meter that uses RS485 or Ethernet communications. Best of all, the software is completely free!
Watch a video demo of Acuview software.

Acuview software is a PC-based data logging and reporting software designed to extend the capabilities of any Acuvim power meter that uses RS485 or Ethernet communications. Best of all, the software is completely free!
Product brochures
Software Downloads
Software Screenshots
Technical documents
Product manuals
Video