Home » EIG Shark 100-S Electronic Sub-Meter w/ Advanced WIFI Ethernet Capability
EIG Shark 100-S Electronic Sub-Meter w/ Advanced WIFI Ethernet Capability
Yes! It's in stock. 10+ ready to ship
Yes! It ships for free.
Yes! Next day delivery available.
Yes! It ships for free.
Yes! Next day delivery available.
Call for Price




The Electro-Industries/Gaugetech (EIG) Shark 100-S Electronic Sub-Meter with Advanced WIFI Ethernet Capability is one of the most advanced electrical submeters. This high performance product is designed to measure revenue grade electrical energy usage and communicate back that information using modern communication mediums. The unit supports RS485, RJ45 Ethernet or IEEE 802.11 Wi-Fi© Ethernet connections. This allows it to be placed anywhere within a facility and have it communicate back to central software quickly and automatically. one of the most advanced electrical submeters
The unit uses standard 5 or 1 amp CTs (either split or donut). It surface mounts to any wall and is easily programmed in minutes. The unit is designed specifically to be a low cost, highly accurate submeter with advanced communication and easy installation.
The EIG Shark 100-S directly interfaces with most building management systems. Communication cab abilities include RS485, RJ45 Ethernet, or IEEE 802.11 WiFi© which make the Shark 100-S an easy and economical solution for many applications including:
IrDA Port for PDA Read
Using the infrared port, the EIG Shark 100-S can view and capture data using either a laptop or a pocket PC based PDA.
Standard RS485 Communication
Standard communication includes an RS485 output speaking Modbus protocol. This allows the units to be connected to any serial RS485 bus using the Modbus interface. The unit will communicate easily with most building automation or other software systems.
Wi-Fi© or Land Based Ethernet
The unit has an option to connect a WiFi© or RJ45 connection. This allows the EIG Shark100-S to be used on standard WIFI base stations. The unit is assigned an IP address and it communicates Modbus protocol over Ethernet TCP / I P.
KYZ Pulse
In applications in which a pulse is needed, the unit also provides a KYZ output which pulses proportional to the amount of energy consumed. This is used for pulse counting applications or for building management systems where serial or Ethernet protocol is not available.

Wireless Ethernet Provides a Simple Wireless Architecture
Benefits of Wireless Ethernet over Dedicated 900 MHz Spread Spectrum
The unit uses standard 5 or 1 amp CTs (either split or donut). It surface mounts to any wall and is easily programmed in minutes. The unit is designed specifically to be a low cost, highly accurate submeter with advanced communication and easy installation.
The EIG Shark 100-S directly interfaces with most building management systems. Communication cab abilities include RS485, RJ45 Ethernet, or IEEE 802.11 WiFi© which make the Shark 100-S an easy and economical solution for many applications including:
- Universities
- Commercial Buildings
- Shopping Malls
- Industrial Submetering
- Government Facilities
IrDA Port for PDA Read
Using the infrared port, the EIG Shark 100-S can view and capture data using either a laptop or a pocket PC based PDA.
Standard RS485 Communication
Standard communication includes an RS485 output speaking Modbus protocol. This allows the units to be connected to any serial RS485 bus using the Modbus interface. The unit will communicate easily with most building automation or other software systems.
Wi-Fi© or Land Based Ethernet
The unit has an option to connect a WiFi© or RJ45 connection. This allows the EIG Shark100-S to be used on standard WIFI base stations. The unit is assigned an IP address and it communicates Modbus protocol over Ethernet TCP / I P.
KYZ Pulse
In applications in which a pulse is needed, the unit also provides a KYZ output which pulses proportional to the amount of energy consumed. This is used for pulse counting applications or for building management systems where serial or Ethernet protocol is not available.

Wireless Ethernet Provides a Simple Wireless Architecture
Benefits of Wireless Ethernet over Dedicated 900 MHz Spread Spectrum
- Standard Infrastructure (No Dedicated Hardware)
- Low Cost to Deploy and Expand
- Superior Speed Over Dedicated Wireless Networks
- Significantly Easier to Configure and Maintain
- Secure Connection - 128 bit Encryption
- Standard Modbus TCP Data Stream
- Can be Easily Integrated through Internet
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
- 0.2% Class Revenue Certifiable Energy and Demand Submeter
- Meets ANSI C12.20 (0.2%) and IEC 687 (0.2%) Classes
- Multifunction Measurement Capability
- Power Quality Measurements
- 3 Line 0.56" Bright Red LED Display
- % of Load Bar
- Ethernet and Wireless Ethernet
- Serial RS485 Communication
- Modbus RTU and Modbus TCP (Over Ethernet)
- Direct Interface with Most Building Management Systems
Voltage Inputs
0-416 Volts Line To Neutral, 0-721 Volts Line to Line
Universal Voltage Input
Input Withstand Capability – Meets IEEE C37.90.1 (Surge Withstand Capability)
Programmable Voltage Range to Any PT ratio
Supports: 3 Element WYE, 2.5 Element WYE, 2 Element Delta, 4 Wire Delta Systems
Burden: 0.36VA per phase Max at 600V, 0.014VA at 120 Vo l t s
Current Inputs
Class 10: (0 to 11) A, 5 Amp Nominal
Class 2: (0 to 2) A, 1A Nominal Secondary
Programmable Current to Any CT Ratio
Burden 0.005VA per phase Max at 11Amps
5mA Pickup Current
Isolation
All Inputs and Outputs are galvanically isolated to 2500 Volts AC.
Environmental Rating
Storage: (-40 to +85)° C
Operating: (-30 to +70)° C
Humidity: to 95% RH
Non-Condensing
Sensing Method
True RMS
Sampling at 400+ Samples per Cycle on all channels measured readings simultaneouslyHarmonic %THD (% of Total Harmonic Distortion)
Update Rate
Watts, VAR and VA- 1 0 0 m s e c
All other parameters-1second
Power Supply
(90 to 400) Volts AC and (100 to 370) Volts DC. Universal AC/DC Supply
Burden: 16VA max.
Communication Format
2 Com Ports
RS485 Port (Through Mounting Plate)
IrDA (Through Faceplate)
Protocol Modbus RTU, Modbus ASCII
Com Port Baud Rate: (9600 to 57,600)
Com Port Address: 0-247
8 Bit, No parity
Modbus RTU or ASCII Protocols
Ethernet
802.11b Wireless
10 Base T Ethernet (RJ45)
Wireless Security 128 Bit
Modbus TCP Protocol
Dimensions and Shipping
Weight: 4 lbs
Compliance:
IEC 687 (0.2% Accuracy)
ANSI C12.20 (0.2% Accuracy)
ANSI (IEEE) C37.90.1 Surge Withstand
ANSI C62.41 – Burst
IEC1000-4-2 – ESD
IEC1000-4-3 – Radiated Immunity
IEC 1000-4-4 – Fast Tr a n s i e n t
IEC 1000-4-5 – Surge Immunity
0-416 Volts Line To Neutral, 0-721 Volts Line to Line
Universal Voltage Input
Input Withstand Capability – Meets IEEE C37.90.1 (Surge Withstand Capability)
Programmable Voltage Range to Any PT ratio
Supports: 3 Element WYE, 2.5 Element WYE, 2 Element Delta, 4 Wire Delta Systems
Burden: 0.36VA per phase Max at 600V, 0.014VA at 120 Vo l t s
Current Inputs
Class 10: (0 to 11) A, 5 Amp Nominal
Class 2: (0 to 2) A, 1A Nominal Secondary
Programmable Current to Any CT Ratio
Burden 0.005VA per phase Max at 11Amps
5mA Pickup Current
Isolation
All Inputs and Outputs are galvanically isolated to 2500 Volts AC.
Environmental Rating
Storage: (-40 to +85)° C
Operating: (-30 to +70)° C
Humidity: to 95% RH
Non-Condensing
Sensing Method
True RMS
Sampling at 400+ Samples per Cycle on all channels measured readings simultaneouslyHarmonic %THD (% of Total Harmonic Distortion)
Update Rate
Watts, VAR and VA- 1 0 0 m s e c
All other parameters-1second
Power Supply
(90 to 400) Volts AC and (100 to 370) Volts DC. Universal AC/DC Supply
Burden: 16VA max.
Communication Format
2 Com Ports
RS485 Port (Through Mounting Plate)
IrDA (Through Faceplate)
Protocol Modbus RTU, Modbus ASCII
Com Port Baud Rate: (9600 to 57,600)
Com Port Address: 0-247
8 Bit, No parity
Modbus RTU or ASCII Protocols
Ethernet
802.11b Wireless
10 Base T Ethernet (RJ45)
Wireless Security 128 Bit
Modbus TCP Protocol
Dimensions and Shipping
Weight: 4 lbs
Compliance:
IEC 687 (0.2% Accuracy)
ANSI C12.20 (0.2% Accuracy)
ANSI (IEEE) C37.90.1 Surge Withstand
ANSI C62.41 – Burst
IEC1000-4-2 – ESD
IEC1000-4-3 – Radiated Immunity
IEC 1000-4-4 – Fast Tr a n s i e n t
IEC 1000-4-5 – Surge Immunity
Product brochures
No user reviews available.