EIG Shark 100T
Datasheet

Call for Price

Recommended Options
Add AL101 current transformer - solid core, 5A output, 1.05" opening: +$39.95
Add AL201 current transformer - solid core, 5A output, 1.05" opening: +$39.36
Add Veris H6810-200A-5A Split Core Current Transformer - 200A - Output 5A: +$76.56
Add AL500 current transformer - solid core, 5A output, 1.05" opening: +$39.36
Add Veris H6811-400A-5A 400A Split Core Current Transformer - 400A - Output 5A: +$119.68




Designed to address the most demanding applications, the Shark 100 surpasses others providing advanced performance metering in a low cost, compact, panel meter design. Based on an all new platform, this meter significantly outperforms other devices many times its price. This unit is perfect for new metering applications and for a simple replacement to existing analog meters.

The unit utilizes high speed DSP technology with high resolution A/D conversion to provide revenue certifiable accuracy for Utility Billing, Substation Metering, Sub-metering and Critical Metering applications.

Ordering Options



The Shark 100 was engineered to be as easy to use and install as possible. From user interface to mechanical construction, many hours were spent to make the Shark straightforward and intuitive so an installer with minimal meter experience and training can succeed with the product. Shark is programmed using a PDA, a PC Computer or through a simple keypad interface. By using the PC or PDA, a technician or electrician can see a visual phasor diagram of the vectors insuring that CT and Voltage polarities are correct. All inputs are color coordinated and have clear simple to understand labeling to avoid cross wiring mistakes.

There are also two communications ports available on the Shark100 - One port provides RS485 communication speaking Modbus ASCII or Modbus RTU protocol.
(9600 - 57,600 baud) and a second IrDA port is available for remote setup, polling and reading. DNP 3.0 protocol is also included with V-Switch packages V3 and V4. (See the 'features' or 'configure' tab for details of V-Switch package options.)

Applications

  • Utility Energy Billing
  • Substations Panels
  • Power Generation
  • Sub-Metering
  • Commercial Metering
  • Industrial Metering
  • Campus Metering
  • Analog Meter Replacement
  • Original Equipment Power Metering

Measurement Options

The Shark 100 is equipped with EIG’s exclusive V-Switch® Technology. V-Switch®, virtual switch technology allows users, OEMs or Power Utilities to minimize different levels of meters and reduce stocking to one type of hardware. As such V-Switch measurement options can be selected at time of purchase.

  • V-Switch 1 – Volts and Amps Meter – Default
  • V-Switch 2 – Volts, Amps, kW, kVAR, PF, kVA, Freq.
  • V-Switch 3 – Volts, Amps, kW, kVAR, PF, kVA, Freq., kWh, kVAh, kVARh and DNP 3.0
  • V-Switch 4 – Volts, Amps, kW, kVAR, PF, kVA, Freq., kWh, kVAh, kVARh, %THD Monitoring, Limit Exceeded Alarms and DNP 3.0
The Good:


The Bad:


The Bottom Line:

Full Review

Note to Reader : The description below applies to both the Shark100 (power meter with display) AND Shark 100T (transducer power meter, no display) products. Images in this description may show either product.


Electro Industries/GaugeTech introduces industry leading metering technology. Designed to address the most demanding applications, the Shark 100 surpasses others providing advanced performance metering in a low cost, compact, panel meter design. Based on an all new platform, this meter significantly outperforms other devices many times its price. This unit is perfect for new metering applications and for a simple replacement to existing analog meters.

The unit utilizes high speed DSP technology with high resolution A/D conversion to provide revenue certifiable accuracy for Utility Billing, Substation Metering, Sub-metering and Critical Metering applications.








New V-Switch® Technology

The Shark 100 is equipped with EIG’s exclusive V-Switch® Technology. V-Switch®, virtual switch technology allows users, OEMs or Power Utilities to minimize different levels of meters and reduce stocking to one type of hardware. In this manner, the meter can be expanded to meet the specific application even after installation. Using V-Switches, you can purchase what you require now and field upgrade functionality as needed, which allows you to optimize your investment. Advanced versions of the Shark 100 (V3 and V4) also include DNP 3.0 communication protocol.


Available V-Switches:

  • V-Switch 1 – Volts and Amps Meter – Default
  • V-Switch 2 – Volts, Amps, kW, kVAR, PF, kVA, Freq.
  • V-Switch 3 – Volts, Amps, kW, kVAR, PF, kVA, Freq., kWh, kVAh, kVARh and DNP 3.0
  • V-Switch 4 – Volts, Amps, kW, kVAR, PF, kVA, Freq., kWh, kVAh, kVARh, %THD Monitoring, Limit Exceeded Alarms and DNP 3.0


Accuracy percentage of Voltage L-N, Voltage L-L, and Current is 0.1%. For Watts, Wh, VARs, VARh, VA, Vah, and PF the accuracy is 0.2%. Accuracy for Frequency is 0.01 Hz, %THD is 1%, and for % load bar 1-120% readings.

The Shark 100 is a traceable revenue meter, that contains a utility grade test pulse allowing power providers to verify and confirm that the meter is performing to its rated accuracy.








Easy to Use and Install

The Shark 100 was engineered to be as easy to use and install as possible. From user interface to mechanical construction, many hours were spent to make the Shark straightforward and intuitive so an installer with minimal meter experience and training can succeed with the product. Shark is programmed using a PDA, a PC Computer or through a simple keypad interface. By using the PC or PDA, a technician or electrician can see a visual phasor diagram of the vectors insuring that CT and Voltage polarities are correct. All inputs are color coordinated and have clear simple to understand labeling to avoid cross wiring mistakes.



  • DIN Mounting
  • ANSI Mounting
  • Bright .56” 3 Line LED displays
  • Auto Scroll Feature
  • Large Easy to Press Buttons
  • Analog Style % of Load Bar. Provides Analog Perception to the Digital Meter
  • Intuitive, Simple to Use Interface
  • Small Footprint







Advanced Communication Capability with IrDA Interface

  • Two independent communication ports with advanced features are provided by the Shark 100
  • One port provides RS485 communication speaking Modbus ASCII or Modbus RTU protocol.
  • 9600 baud to 57,600 baud
  • Optical IrDA port which allows unit to be set up and programmed using PDA or remote laptop without communication cable
  • Point at meter with IrDA-equipped PC or PDA and configure it
  • Communicator EXT Copilot is Windows CE software package which allows you to point at a Shark, configure it and poll readings


Superior Voltage and Current Inputs

  • Ruggedly designed for harsh electrical applications on both high and low voltage power systems.
  • Voltage inputs allow measurement to 416 Volts Line to Neutral and 721 Volts Line to Line, which ensures proper meter safety when wiring directly to high voltage systems.
  • Current inputs use a dual input method: CT Pass Through and Current “Gills”
  • CT Pass Through – Preferable to utility users when sharing relay class CTs because the CT passes directly through the meter without any physical termination on the meter, which ensures the meter cannot be a point of failure on the CT circuit.
  • Current “Gills” – This method provides additional ultra rugged termination pass-through bars, allowing the CT leads to be terminated on the meter.
Utility Peak Demand Metering

The Shark 100 provides user configured fixed window or rolling window demand. This all you to set up the particular utility demand profile. A Fixed window demand is the demand used over a user configured demand period (usually 5, 15 or 30 minutes). A rolling window demand is a fixed window demand that moves for a user specified sub-interval period. An example is would be a 15 minute demand using 3 sub-interval provides a new demand reading every 5 minutes based on the last 15 minutes. Readings for kW, kVAR, kVA and PF are calculated using utility demand features. All other parameters offer max and min capability over the user selectable averaging period. Voltage provides an instantaneous max and min reading displaying the highest surge and lowest sag seen by the meter.

Physical Configuration

The unit mounts directly in an ANSI C39.1 (4” Round form) and an IEC 92 mm DIN square form. This is perfect for new installations and for existing panels. In new installations, simply use existing DIN or ANSI punches. For existing panels, pull out old analog meters and place this meter in its place. The meter uses standard voltage and current inputs so that CT and PT wiring does not need to be replaced.

 

 
Voltage Inputs
0-416 Volts Line To Neutral, 0-721 Volts Line to Line
Universal Voltage Input
Input Withstand Capability – Meets IEEE C37.90.1 (Surge Withstand Capability)
Programmable Voltage Range to Any PT ratio
Supports: 3 Element WYE, 2.5 Element WYE, 2 Element Delta, 4 Wire Delta Systems
Burden: 0.36VA per phase Max at 600V, 0.014VA at 120 Vo l t s
Input wire gauge max (AWG 12 / 2.5mm2 )
N o t e : Accuracy specs doubled for 2.5 Element connections.

Current Inputs
Class 10: (0 to 11) A, 5 Amp Nominal
Class 2: (0 to 2) A, 1A Nominal Secondary
Fault Current Withstand: 100 Amps for 10 Seconds, 300 Amps for 3 Seconds, 500 Amps for 1 Second.
Programmable Current to Any CT Ratio
Burden 0.005VA per phase Max at 11Amps
5mA Pickup Current
Pass through wire gauge dimension: 0.177” / 4.5mm

Isolation
All Inputs and Outputs are galvanically isolated to 2500 Volts AC.

Environmental Rating
Storage: (-40 to +85)° C
Operating: (-30 to +70)° C
Humidity: to 95% RH Non-
Condensing
Faceplate Rating:
NEMA12
(Water Resistant)
Mounting Gasket Included

Sensing Method
True RMS
Sampling at 400+ Samples per Cycle on all channels measured readings simultaneously Harmonic %THD (% of Total Harmonic Distortion)

Update Rate
Watts, VAr and VA-100msec
All other parameters-1second

Power Supply
(90 to 265) Volts AC and (100 to 370) Volts DC. Universal AC/DC Supply
Burden: 10VA max.

Communication Format
2 Com Ports (Back and Face Plate)
RS485 Port (Through Back Plate)
IrDA (Through Faceplate)
Com Port Baud Rate: (9600 to 57,600)
Com Port Address: 0-247
8 Bit, No parity
Modbus RTU, ASCII or DNP 3.0 Protocols

Dimensions and Shipping
Weight: 2 lbs
Basic Unit: H4.85 x W4.82 x L4.25
Shark100 - mounts in 92mm DIN and ANSI C39.1 Round Cut-outs
S h a r k 1 0 0 T-DIN rail mounted transducer
Shipping Container Dimensions: 6” cube

Compliance:
IEC 687 (0.2% Accuracy)
ANSI C12.20 (0.2% Accuracy)
ANSI (IEEE) C37.90.1 Surge Withstand
ANSI C62.41 (Burst)
IEC1000-4-2 – ESD
IEC1000-4-3 – Radiated Immunity
IEC 1000-4-4 – Fast Tr a n s i e n t
IEC 1000-4-5 – Surge Immunity
No user reviews available.
Recommended Accessories

Adapters
Name Price Quantity
EIG RS485 to RS232 Converter Call for Pricing
Communications
Solid Core CTs
Split Core CTs

Have a Question?

Do you have a question for us? Can't find what you're looking for? We're glad to help you. Fill out the simple form below and we'll get back to you as soon as possible.

Name
Email
Phone
Message
In order to prevent spam through the form, please enter the passcode word displayed below. If you cannot read the word clearly, you can change the passcode image.

Enter Passcode: