Home » AEMC SDL A402 Sentinel Current Logger
AEMC SDL A402 Sentinel Current Logger
Sorry, this product is discontinued and is no longer available for purchase. Please call 1-877-766-5412 to find a suitable replacement.DATApro DP-4C 4 Channel Current Datalogger is a suggested replacement model.




The AEMC SDL A402 Sentinel Data Logger is a four-channel current recording devices with NiMH batteries and is AC powered. The SDL402 are designed for use with AEMC detachable current probes or with AmpFlex sensors when using Hall Effect Current Probes get DC current measurements.
Real-time display of waveforms and harmonics is available with the DataView® software, which is included. Programmable storage rate and storage modes, combined with simple one button operation, make this a versatile and easy-to-use data logger, perfect for a variety of applications.
Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±3Hz around the nominal line frequency (50 or 60Hz). Measurements are calculated from these 64 samples for all input channels. The Sentinel® records RMS values for each of the inputs at a rate
of up to four times per second. Measurements for each channel are taken sequentially. RMS calculations from the 64 samples are performed on each single line cycle measured for each input. DC measurements are also on all voltage models and probe dependent on current models.
The main advantage of the Sentinel® logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using the DataView® software, which is included. Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port facilitates the transfer of data from internal memory to the computer for analysis.
Three LEDs on the front panel (red, yellow and green) indicate recording and memory status at a glance. User selectable storage rate, recording length and recording modes are provided.
Extended Recording Mode (XRM™)
This unique recording mode provides the opportunity to continuously record over long periods of time by reducing the stored samples of the oldest data and maintaining matching resolution for the newest data. Each time the memory fills using XRM every other stored sample is discarded making room for newer samples. This process continues until the recording is manually stopped.
FIFO
When the memory is full, a block of the oldest stored data is discarded to make room for the new sampled data. The sample/storage rate is unchanged.
Stop When Full
The memory is filled at the programmed sample/storage rate from four per second to one every 12 hours. When the memory is full, the recording stops automatically.
Real-time display of waveforms and harmonics is available with the DataView® software, which is included. Programmable storage rate and storage modes, combined with simple one button operation, make this a versatile and easy-to-use data logger, perfect for a variety of applications.
Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±3Hz around the nominal line frequency (50 or 60Hz). Measurements are calculated from these 64 samples for all input channels. The Sentinel® records RMS values for each of the inputs at a rate
of up to four times per second. Measurements for each channel are taken sequentially. RMS calculations from the 64 samples are performed on each single line cycle measured for each input. DC measurements are also on all voltage models and probe dependent on current models.
The main advantage of the Sentinel® logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using the DataView® software, which is included. Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port facilitates the transfer of data from internal memory to the computer for analysis.
Three LEDs on the front panel (red, yellow and green) indicate recording and memory status at a glance. User selectable storage rate, recording length and recording modes are provided.
Extended Recording Mode (XRM™)
This unique recording mode provides the opportunity to continuously record over long periods of time by reducing the stored samples of the oldest data and maintaining matching resolution for the newest data. Each time the memory fills using XRM every other stored sample is discarded making room for newer samples. This process continues until the recording is manually stopped.
FIFO
When the memory is full, a block of the oldest stored data is discarded to make room for the new sampled data. The sample/storage rate is unchanged.
Stop When Full
The memory is filled at the programmed sample/storage rate from four per second to one every 12 hours. When the memory is full, the recording stops automatically.
The Good:
The Bad:
The Bottom Line:
The Bad:
The Bottom Line:
Full Review
- True RMS current measurements
- DC current measurements when used with Hall Effect Current Probes on Model SDL A402
- Low-cost, self-contained, portable
- Measures up to 1000A (probe dependent)
- Programmable storage mode
- Programmable storage rate
- Records up to 480,000 measurements (1MB)
- 64 samples per cycle
- Includes DataView® software
- Optically isolated USB 2.0 communication
- Detachable current probes
- 600V Cat. III, 300V Cat. IV
- Display and analyze real-time waveform and harmonic data on your PC on demand
- Display waveforms, trend graphs, harmonics and text summaries
- Configure all data logger functions and parameters from your PC including sample rate, recording length, channel configuration and more
- Create and store a complete library of configurations that can be uploaded to the logger as needed
- Zoom in and out and pan through sections of the graph to analyze the data
- Download, display and analyze recorded data
- Create custom views and reports
- Print reports using standard or custom templates you design
- Free on-line software upgrades
MINIMUM SYSTEM REQUIREMENTS- Windows®98/2000/ME/XP
- 128MB of RAM for Windows®98/2000/ME (256MB recommended)
- 256MB of RAM for Windows®XP
- 35MB of Hard Disk Space (200MB recommended)

Tabbed configuration dialog boxes allow for easy setup of all recording functions.

Recorded data dialog box allows clear and easy access to all stored data sessions in the Sentinel® data logger. You can choose an individual session or all sessions to download.

Clear and easy-to-read status update is displayed when DataView® and Sentinel® Loggers connect. From this menu you can view real-time data, download recorded data and configure the Sentinel® Logger.

Typical real-time waveform display of data being monitored or recorded.

Harmonic content displayed in bargraph form in real time using DataView® for any or all inputs.

Harmonic content information can be displayed in a text format for all harmonics out to the 30th.
Product brochures
Product manuals
No user reviews available.