Dent CT-R72-1310-U Current Transformer
Downloads:
datasheet



Dent CT-R72-1310-U Current Transformer

Model: CT-R72-1310-U

72" Rocoil Flexible Current Transformers. 5 to 5000A, Unterminated.

$460.00 USD

1 to 2 Weeks


DENT RoCoil™ Flexible Current Transformers

TheDENT RoCoil™Current Transformers have been designed for accurate non?intrusivemeasurement of AC current, pulsed DC or distorted waveforms. Thistype ofsensormay be used to measure AC current over a wide dynamic range and from40Hz to 5 kHz.Note: The RoCoil™may require use ofintegrator/ ampli?er. See also RoCoil mV™.

RoCoil™ Dimensions

The Dimensions for RoCoil CTs
Dimensions R16
40 cm (16")
R24
60 cm (24")
R36
90 cm (36")
R72
183cm (72")
A - Window Size 13 cm(5") 19 cm(7") 26 cm(10") 56 cm(22")
B - Transformer Coil O.D. 15 cm(6") 21 cm(8") 29 cm(11") 58 cm(23")
C - Transformer Length 40 cm(16") 60 cm(24") 90 cm(36") 180 cm(72")
D - Locking ConnectorO.D. 3.6 cm(1.4")
E - Transformer Coil Diameter 1.5 cm(0.6")
F - Wire Lead Total Length 2m(80")

Key Specifications

Four Lengths 40cm(16"),60cm(24"),
90cm(36"), 183cm(72")
Window Size 13cm(5"),19cm(7"),
26cm(10"), 58cm(23")
Output Signal(di/dt) 131mVAC/1000A @ 60Hz
110mVAC/1000A @ 50Hz
Current Range 5 - 5000AAC
Accuracy < 1%

Electrical

All accuraciesspecified at 20°C (±2°C)withRoCoil™centered on conductor.

Output Signal 131mV/1000A@ 60Hz
110mV/1000A@ 50Hz
Wire Colors White = (+) positve
Brown = (?) negatve
Bare wire = shield
Phasing Arrow Points Towards Load
Phase Shift < 1° at 50/60Hz
Frequency Range 40Hzto 5 kHz
Useful Current Range 5 - 5000A AC*
Linearity ± 0.2%
Conductor Position Sensitivity ± 2%maximum
In?uence of External Field ± 1.5%maximum
Temperature Sensi?vity 0.07% per°C

Mechanical

Coil Materials Blue thermoplas?c rubber, ?ame retardantUL 94 V?0 rated
Coupling Materials PolypropyleneUL 94 V?0 rated
Shielding 85% transducer, 100% output lead
Working Temp ?20 °C to +80 °C (?4°to +176 °F)

Safety

Working Voltage 1000 Vrmsmaximum
Dielectric Strength 7400 VAC around coil
1000 VAC rated leads
Cert?cations Conforms to UL STD61010?1
Certi?ed to CAN/CSA STDC22.2
No. 61010

Accessories

Click on a category to view a selection of compatible accessories with the Dent CT-R72-1310-U Current Transformer.

Dent RoCoil TCA-5 5A Transconductance Amplifier TCA-5-AO 19278
RoCoil TCA-5. 5A Transconductace Amplifier. For use with DENT RoCoil CTs. Includes Amplifier Only. Does not include power supply or RoCoil CTs.
$650.00 USD

Learn More

Dent RoCoil TCA-5 Low Voltage Kit TCA-5-LV-KIT 19234
RoCoil TCA-5. For use with DENT RoCoil CTs. Includes Low Voltage (120/240V AC) power supply for use on 1-phase services, wiring harness, and TS35/7 DIN rail. Does not include RoCoil CTs.
$750.00 USD

Learn More

Dent RoCoil TCA-5 High Voltage Kit TCA-5-HV-KIT 19235
RoCoil TCA-5. For use with DENT RoCoil CTs. Includes High Voltage (200/500V AC) power supply for use on 3-phase services, wiring harness, and TS35/7 DIN rail. Does not include RoCoil CTs.
$750.00 USD

Learn More