Acuvim-EL Series of Power Meters
Downloads:
manual


Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters Acuvim-EL Series of Power Meters

Acuvim-EL Series of Power Meters

Model: Acuvim-EL | Order No: Acuvim-EL Series

Built for energy and facilities professional who need a low cost single/three phase non-revenue grade time-of-use meter. Available with LCD display or DIN Rail mount transducer (no display). All versions include MODBUS RS485 output.

Help with Ordering

Select a Model

Include an Enclosure for the Acuvim L series

Clear selected options

Acuvim-EL-D-1A-P1

Acuvim-EL Power Meter with MODBUS RS485 output and Time-of-Use (TOU), plus integrated on-board LCD display, 1A input for current transformers and wide-range AC power supply input.

$350.00 USD

3 to 4 Weeks


Acuvim-EL-D-1A-P2

Acuvim-EL Power Meter with MODBUS RS485 output and Time-of-Use (TOU), plus integrated on-board LCD display, 1A input for current transformers and low voltage DC power supply input.

$410.00 USD

3 to 4 Weeks


Acuvim-EL-D-5A-P1

Acuvim-EL Power Meter with MODBUS RS485 output and Time-of-Use (TOU), plus integrated on-board LCD display, 5A input for current transformers and wide-range AC power supply input.

$350.00 USD

3 to 4 Weeks


Acuvim-EL-D-5A-P2

Acuvim-EL Power Meter with MODBUS RS485 output and Time-of-Use (TOU), plus integrated on-board LCD display, 5A input for current transformers and low voltage DC power supply input.

$410.00 USD

3 to 4 Weeks


Acuvim-EL-M-1A-P1

Acuvim-EL Power Meter with MODBUS RS485 output and Time-of-Use (TOU), plus DIN-rail mount transducer form factor (no local display), 1A input for current transformers and wide-range AC power supply input.

$330.00 USD

3 to 4 Weeks


Acuvim-EL-M-1A-P2

Acuvim-EL Power Meter with MODBUS RS485 output and Time-of-Use (TOU), plus DIN-rail mount transducer form factor (no local display), 1A input for current transformers and low voltage DC power supply input.

$360.00 USD

3 to 4 Weeks


Acuvim-EL-M-5A-P1

Acuvim-EL Power Meter with MODBUS RS485 output and Time-of-Use (TOU), plus DIN-rail mount transducer form factor (no local display), 5A input for current transformers and wide-range AC power supply input.

$330.00 USD

3 to 4 Weeks


Acuvim-EL-M-5A-P2

Acuvim-EL Power Meter with MODBUS RS485 output and Time-of-Use (TOU), plus DIN-rail mount transducer form factor (no local display), 5A input for current transformers and low voltage DC power supply input.

$360.00 USD

3 to 4 Weeks


About the Acuvim-EL

Built for energy and facilities professional who need a low cost single/three phase non-revenue grade time-of-use meter. Available with LCD display or DIN Rail mount transducer (no display). All versions include MODBUS RS485 output.

The Acuvim-EL also features Load Run Time (TOU) and 1 RS485 port with Modbus RTU protocol.


The Acuvim-L Series

The Acuvim-L series are multifunction power meters manufactured by Accuenergy. It is the ideal choice for monitoring and controlling of power distribution system.

Acuvim-L may be used as a data gathering device for an intelligent Power Distribution System or a Plant Automation System. All monitoring data is available via digital RS485 communication port running Modbus® Protocol (excluding Acuvim AL and BL models).

The quality of the power system is important with increasing use of electronic loads such as computers, ballasts or variable frequency drives. With the Acuvim-L power analysis option, any phase current or voltage can be displayed and the harmonic content calculated. By knowing the harmonic distribution, action can be taken to prevent overheated transformers, motors, capacitors, neutral wires and nuisance breaker trips. Redistribution of the system loading can also be determined.


Key Features

Metering

  • Voltage V1, V2, V3, V12, V23, V31
  • Current I1, I2, I3, In
  • Power P1, P2, P3, Psum
  • Reactive Power Q1, Q2, Q3, Qsum
  • Apparent Power S1, S2, S3, Ssum
  • Frequency F
  • Power Factor PF1, PF2, PF3, PF
  • Energy Ep_imp, Ep_exp
  • Reactive Energy Eq_imp, Eq_exp
  • Apparent Energy Es
  • Demand Dmd_I1, Dmd_I2, Dmd_I3, Dmd_P, Dmd_Q, Dmd_S

Monitoring

  • Power Quality (functions not included with the Acuvim-KL)
  • Voltage Harmonics 2nd to 15th and THD( Acuvim-DL is from 2nd to 25th)
  • Current Harmonics 2nd to 15th and THD( Acuvim-DL is from 2nd to 25th)
  • Voltage Unbalance Factor U_unbl (all models excluding the Acuvim-KL)
  • Current Unbalance Factor I_unbl (all models excluding the Acuvim-KL)
  • Max/Min Statistics (all models excluding the Acuvim-KL)
  • Meter Running Time and Load Running Time (Acuvim-DL/EL/KL)

Alarms

Two (2) parameters may be set within a specified time interval. If indicated parameter is over or under its setting limit and persists over the specified time interval, the event will be recorded with time stamps and trigger the alarm DO output. The indicated parameter can be selected from any of the 35 parameters available.

Communication

RS485, industry standard Modbus® RTU protocol; (Only on models CL/DL/EL/KL)
Option the second RS485, Modbus® RTU protocol; or PROFIBUS-DP/V0 (available for the DL/EL Models)
Protocol. (just for Acuvim-DL/EL)

Display

Clear and large character LCD Screen display with white back light; Wide environmental temperature endurance.


Applications

  • Metering of distribution feeders, transformers, generators, capacitor banks and motors.
  • Medium and low voltage systems.
  • Commercial, industrial, utility.
  • Power quality analysis.

Acuvim L Series Communications Options
Acuvim X1 I/O Module for Acuvim-DL and Acuvim-EL Power Meters
The X1 communications module adds 4 digital inputs and 2 digital outputs to Acuvim DL & EL power meters

Acuvim X2 I/O Module for Acuvim-DL and Acuvim-EL Power Meters
The X2 communications module adds 4 digital inputs, 2 digital outputs and RS485 communications to Acuvim DL & EL power meters

MODBUS RS485 to USB Adapter
MODBUS RS485 to USB Adapter converts MODBUS data running via RS485 to USB for use on local PC


Acuvim L Series is DIN Rail Mountable

Mounting & Display Options

The Acuvim II Series is available in two mounting options:

Standard with LCD Display

The standard model is ANSI C39.1 Standard Compliant with a small size 96x96 outline.

DIN Rail Mount (Remote LCD Display Optional)

The DIN Rail compatible units are DIN 43700 Standard Compliant. The Acuvim L series also offers an optional Remote LCD display.


Acuvim L Series Typical Wiring

Typical Wiring Setups for the Acuvim L Series

Specifications

Metering
Parameters Acuvim-L Accuracy Acuvim-EL/KL Accuracy Resolution Range
Voltage 0.5% 0.5% 0.1V 20V~1000kV
Current 0.5% 0.5% 0.001A 0~50000A
Current Demand 0.5% 0.5% 0.001A 0~50000A
Power 1.0% 0.5% 1W -9999MW~9999MW
Reactive Power 2.0% 0.5% 1var -9999Mvar~9999Mvar
Apparent Power 1.0% 0.5% 0.001V 0~9999MVA
Power Demand 1.0% 0.5% 1W -9999MW~9999MW
Reactive Power Demand 2.0% 0.5% 1var -9999Mvar~9999Mvar
Apparent Power Demand 1.0% 1VA 1VA 0~9999MVA
Power Factor 1.0% 0.5% 0.001 -1.0~1.0
Frequency 0.2% 0.2% 0.01Hz 45.00~65.00Hz
Energy 0.5% 0.5% 0.1kWh 0~99999999.9kWh
Reactive Energy 2.0% 0.5% 0.1kvarh 0~99999999.9kvarh
Apparent Energy 1.0% 0.5% 0.1VAh 0~99999999.9kVAh
Harmonics 2.0% - 0.01% 0~100.0%
Running Time 0.1hrs 0~999999999.9hrs
Communication
RS-485 (Option)
Modbus-RTU Protocol
2-wire connection, Half-duplex, Isolated
1200 to 38400 baud rate
Input
Current Inputs (Each Channel)
Nominal Current 5 A ac
Metering Range 0~6 A ac
Withstand 20Arms continuous100Arms for 1 second, non-recurring
Burden 0.05VA (typical) @5Arms
Pickup Current 10Vac
Accuracy 0.5%
Voltage Inputs (Each Channel)
Nominal Full Scale 400Vac L-N, 690Vac L-L (+20%)
Withstand 1500Vac continuous2500Vac, 50/60Hz for 1minute
Input Impedance 45Hz~65Hz
Pickup Voltage 10Vac
Accuracy 0.5%
Energy Accuracy (Acuvim-EL)
Active (according to IEC 62053-22) Class 0.5s(according to ANSI C12.20) Class 0.5
Reactive (according to IEC 62053-23) Class 2
Harmonic Resolution
Metered Value 2nd ~ 15th harmonics(THD of Acuvim-DL is 2nd to 25th)
Control Power
Universal AC or DC
AC/DC Control Power
Operating Range 100~415Vac, 50/60Hz, 100~300Vdc
Burden 3W
Withstand 3250Vac, 50/60Hz for 1 minute
Low Voltage DC Control Power (Optional)
Operating Range 20~60Vdx
Burden 3W
Digital Output Option
Digital Output (DO) (Photo-MOS)
Voltage Range 0~250Vac/dc
Load Current 100mA (Max)
Output Frequency 25Hz, 50% Duty Ratio
Isolation Voltage 2500V
Digital Input Option
Digital Output (DI)
Input Voltage Range 20~250Vac/dc
Input Current (Max) 2mA
Start Voltage 15V
Stop Voltage 5V
Pulse Frequency (Max) 100Hz, 50% Duty Ratio
SOE Resolution 2ms
Operating Environment
Operation Temperature -25°C to 70°C
Storage Temperature -40°C to 85°C
Relative Humidity 5% to 95% non-condensing
Pollution Degree 2
Standard Compliance
Product
USA UL 61010-1
Canada cUL 61010-1
Europe IEC 61010-1
Emission
Radiated/Conducted FCC Part 15 Subpart B, Class A
Radiated/Conducted EN 55011
Harmonic IEC 61000-3-2
Voltage Fluctuation IEC 50081-2
Radio Interference IEC 50081-2
Immunity
ESD IEC 61000-4-2
Radiated, radio-frequency, electromagnetic field IEC 61000-4-3
Electrical fast transient/bust IEC 61000-4-4
Surge IEC 61000-4-5
Conducted disturbances IEC 61000-4-6
Power frequency magnetic field IEC 61000-4-8
Voltage dips and interruptions IEC 61000-4-11
Generic Immunity Standard for Industrial Environment EN 50082-2

Acuvim II Series Comparison

Function Parameter Acuvim-AL Acuvim-BL Acuvim-CL Acuvim-DL Acuvim-EL Acuvim-KL
Real Time Metering Phase Voltage U1, U2, U3
Real Time Metering Line Voltage U12, U23, U31
Real Time Metering Current I1, I2, I3, In (Acuvim-KL no neutral current measurement)
Real Time Metering Power P1, P2, P3, Psum
Real Time Metering Reactive Power Q1, Q2, Q3, Qsum
Real Time Metering Apparent Power S1, S2, S3, Ssum
Real Time Metering Power Factor PF1, PF2, PF3, PF
Real Time Metering Load Nature L/C/R
Real Time Metering Frequency F Hz
Energy & Demand Energy Ep_imp, Ep_exp
Energy & Demand Reactive Energy Eq_imp, Eq_exp
Energy & Demand Apparent Energy Es
Energy & Demand Current Demand Dmd_I1,Dmd_I2 Dmd_I3
Energy & Demand Power Demand Dmd_Psum, Dmd_Qsum, Dmd_Ssum
Time of Use Energy TOU, 4 Tariffs, 12 Seasons, 14 Schedules
Power Quality Voltage Unbalance U_unbl
Power Quality Current Unbalance I_unbl Trigger, Manual, DI change, Sag/Dips, Swell, Over Current
Power Quality Voltage THD THD_V1, THD_V2, THD_V3
Power Quality Current THD THD_I1, THD_I2, THD_I3
Power Quality Individual Harmonics 2nd~15th (Voltage and Current) (Acuvim-DL is from 2nd to 25th)
Statistics Max Current Demand Dmd_I1_max,Dmd_I2 _max,Dmd_I3_max
Statistics Max Power Demand Dmd_Psum_max, Dmd_Qsum_max, Dmd_Ssum_max
Statistics Max & Min of Voltage
Statistics Max & Min of Current
Hour Running Time Hour
Hour Load Running Time Hour
I/O Energy Pulse Output 2 DO, configured as pulse output for kWh and kvarh, the pulse rate and width can be set
I/O Alarm Output
Communication RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate
Communication Second RS-485 Modbus®-RTU Protocol, 1200~38400 baud rate Opt Opt
Communication Profibus PROFIBUS-DP/V0 Protocol Opt Opt
Extension I/O 4DI, 2DO SOE, Pulse Counter, Pulse output, Alarm output Opt Opt

Acuview Software

As the need to better understand power and energy consumption increases, Accuenergy continues to offer a simple and effective software compliment to our metering products. Combining their meters with the Acuview software suite allows Accuenergy to offer one of the most powerful yet cost effective metering and monitoring solutions in the market.

Acuview Software Features

  • Simple setup feature for fast deployment and configuration Accuenergy meters.
  • Remote and real time monitoring of all meter parameters.
  • Dozens of meters can be connected to a single PC.
  • Multiple meters can be displayed and tiled in one window.
  • Real Time Data Logging.
  • Logging of data from the I/O modules (pulses from Water, gas, flow, etc).
  • All data logged into simple and easy to read Excel spreadsheets (.xls, .csv or .txt formats).
  • SmartSum feature provides aggregate Energy & Demand data for an average of the entire system being monitored.

Accessories

Click on a category to view a selection of compatible accessories with the Acuvim-EL Series of Power Meters.

AccuEnergy AcuCT-5170R-3000:5A Press Open Split Core Current Transformer, 3000A:5A, 5.1 x 7" AcuCT-5170R-3000:5A 88129
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 5.1 x 7". Has a Current Input of 3000A and Output of 5A.
$345.00 USD

Learn More

AccuEnergy AcuCT-0812-100:5 Split Core Current Transformer, 100:5A, 0.83 x 1.22" AcuCT-0812-100:5 87930
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 0.83 x 1.22". Has a Current Input of 100A and Output of 5A.
$53.60 USD

Learn More

AccuEnergy AcuCT-4161R-3000:5A Press Open Split Core Current Transformer, 3000A:5A, 4.1 x 6.1" AcuCT-4161R-3000:5A 88093
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 4.1 x 6.1". Has a Current Input of 3000A and Output of 5A.
$240.00 USD

Learn More

AccuEnergy AcuCT-3135R-1200:5A Press Open Split Core Current Transformer, 1200A:5A, 3.1 x 3.5" AcuCT-3135R-1200:5A 88039
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 3.1 x 3.5". Has a Current Input of 1200A and Output of 5A.
$104.00 USD

Learn More

AccuEnergy AcuCT-2031-400:5 Split Core Current Transformer, 400:5A, 1.97 x 3.15" AcuCT-2031-400:5 19296
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 1.97 x 3.15". Has a Current Input of 400A and Output of 5A.
$83.80 USD

Learn More

AccuEnergy AcuCT-4161R-800:5A Press Open Split Core Current Transformer, 800A:5A, 4.1 x 6.1" AcuCT-4161R-800:5A 88057
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 4.1 x 6.1". Has a Current Input of 800A and Output of 5A.
$240.00 USD

Learn More

AccuEnergy AcuCT-3163-3000:5 Split Core Current Transformer, 3000:5A, 3.15 x 6.3" AcuCT-3163-3000:5 87937
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 3.15 x 6.3". Has a Current Input of 3000A and Output of 5A.
$142.20 USD

Learn More

AccuEnergy AcuCT-5170R-4000:5A Press Open Split Core Current Transformer, 4000A:5A, 5.1 x 7" AcuCT-5170R-4000:5A 88135
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 5.1 x 7". Has a Current Input of 4000A and Output of 5A.
$345.00 USD

Learn More

AccuEnergy AcuCT-0812-250:5 Split Core Current Transformer, 250:5A, 0.83 x 1.22" AcuCT-0812-250:5 87931
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 0.83 x 1.22". Has a Current Input of 250A and Output of 5A.
$53.60 USD

Learn More

AccuEnergy AcuCT-4161R-4000:5A Press Open Split Core Current Transformer, 4000A:5A, 4.1 x 6.1" AcuCT-4161R-4000:5A 88099
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 4.1 x 6.1". Has a Current Input of 4000A and Output of 5A.
$240.00 USD

Learn More

AccuEnergy AcuCT-3135R-1500:5A Press Open Split Core Current Transformer, 1500A:5A, 3.1 x 3.5" AcuCT-3135R-1500:5A 88045
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 3.1 x 3.5". Has a Current Input of 1500A and Output of 5A.
$104.00 USD

Learn More

AccuEnergy AcuCT-2031-600:5 Split Core Current Transformer, 600:5A, 1.97 x 3.15" AcuCT-2031-600:5 19297
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 1.97 x 3.15". Has a Current Input of 600A and Output of 5A.
$83.80 USD

Learn More

AccuEnergy AcuCT-4161R-1000:5A Press Open Split Core Current Transformer, 1000A:5A, 4.1 x 6.1" AcuCT-4161R-1000:5A 88063
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 4.1 x 6.1". Has a Current Input of 1000A and Output of 5A.
$240.00 USD

Learn More

AccuEnergy AcuCT-3163-4000:5 Split Core Current Transformer, 4000:5A, 3.15 x 6.3" AcuCT-3163-4000:5 87938
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 3.15 x 6.3". Has a Current Input of 4000A and Output of 5A.
$152.20 USD

Learn More

AccuEnergy AcuCT-5170R-5000:5A Press Open Split Core Current Transformer, 5000A:5A, 5.1 x 7" AcuCT-5170R-5000:5A 88141
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 5.1 x 7". Has a Current Input of 5000A and Output of 5A.
$345.00 USD

Learn More

AccuEnergy AcuCT-0812-300:5 Split Core Current Transformer, 300:5A, 0.83 x 1.22" AcuCT-0812-300:5 87932
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 0.83 x 1.22". Has a Current Input of 300A and Output of 5A.
$53.60 USD

Learn More

AccuEnergy AcuCT-4161R-5000:5A Press Open Split Core Current Transformer, 5000A:5A, 4.1 x 6.1" AcuCT-4161R-5000:5A 88105
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 4.1 x 6.1". Has a Current Input of 5000A and Output of 5A.
$240.00 USD

Learn More

AccuEnergy AcuCT-4161R-600:5A Press Open Split Core Current Transformer, 600A:5A, 4.1 x 6.1" AcuCT-4161R-600:5A 88051
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 4.1 x 6.1". Has a Current Input of 600A and Output of 5A.
$240.00 USD

Learn More

AccuEnergy AcuCT-2031-800:5 Split Core Current Transformer, 800:5A, 1.97 x 3.15" AcuCT-2031-800:5 19298
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 1.97 x 3.15". Has a Current Input of 800A and Output of 5A.
$83.80 USD

Learn More

AccuEnergy AcuCT-4161R-1200:5A Press Open Split Core Current Transformer, 1200A:5A, 4.1 x 6.1" AcuCT-4161R-1200:5A 88069
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 4.1 x 6.1". Has a Current Input of 1200A and Output of 5A.
$240.00 USD

Learn More

AccuEnergy AcuCT-3163-5000:5 Split Core Current Transformer, 5000:5A, 3.15 x 6.3" AcuCT-3163-5000:5 87939
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 3.15 x 6.3". Has a Current Input of 5000A and Output of 5A.
$162.20 USD

Learn More

AccuEnergy AcuCT-0812-400:5 Split Core Current Transformer, 400:5A, 0.83 x 1.22" AcuCT-0812-400:5 87933
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 0.83 x 1.22". Has a Current Input of 400A and Output of 5A.
$53.60 USD

Learn More

AccuEnergy AcuCT-5170R-1000:5A Press Open Split Core Current Transformer, 1000A:5A, 5.1 x 7" AcuCT-5170R-1000:5A 88111
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 5.1 x 7". Has a Current Input of 1000A and Output of 5A.
$345.00 USD

Learn More

AccuEnergy AcuCT-2031-1000:5 Split Core Current Transformer, 1000:5A, 1.97 x 3.15" AcuCT-2031-1000:5 19299
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 1.97 x 3.15". Has a Current Input of 1000A and Output of 5A.
$83.80 USD

Learn More

AccuEnergy AcuCT-4161R-1600:5A Press Open Split Core Current Transformer, 1600A:5A, 4.1 x 6.1" AcuCT-4161R-1600:5A 88075
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 4.1 x 6.1". Has a Current Input of 1600A and Output of 5A.
$240.00 USD

Learn More

AccuEnergy AcuCT-3135R-600:5A Press Open Split Core Current Transformer, 600A:5A, 3.1 x 3.5" AcuCT-3135R-600:5A 88021
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 3.1 x 3.5". Has a Current Input of 600A and Output of 5A.
$104.00 USD

Learn More

AccuEnergy AcuCT-3147-1000:5 Split Core Current Transformer, 1000:5A, 3.15 x 4.72" AcuCT-3147-1000:5 87934
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 3.15 x 4.72". Has a Current Input of 1000A and Output of 5A.
$98.05 USD

Learn More

AccuEnergy AcuCT-5170R-1600:5A Press Open Split Core Current Transformer, 1600A:5A, 5.1 x 7" AcuCT-5170R-1600:5A 88117
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 5.1 x 7". Has a Current Input of 1600A and Output of 5A.
$345.00 USD

Learn More

AccuEnergy AcuCT-3147-1200:5 Split Core Current Transformer, 1200:5A, 3.15 x 4.72" AcuCT-3147-1200:5 19300
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 3.15 x 4.72". Has a Current Input of 1200A and Output of 5A.
$98.05 USD

Learn More

AccuEnergy AcuCT-4161R-2000:5A Press Open Split Core Current Transformer, 2000A:5A, 4.1 x 6.1" AcuCT-4161R-2000:5A 88081
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 4.1 x 6.1". Has a Current Input of 2000A and Output of 5A.
$240.00 USD

Learn More

AccuEnergy AcuCT-3135R-800:5A Press Open Split Core Current Transformer, 800A:5A, 3.1 x 3.5" AcuCT-3135R-800:5A 88027
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 3.1 x 3.5". Has a Current Input of 800A and Output of 5A.
$104.00 USD

Learn More

AccuEnergy AcuCT-3147-1600:5 Split Core Current Transformer, 1600:5A, 3.15 x 4.72" AcuCT-3147-1600:5 87935
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 3.15 x 4.72". Has a Current Input of 1600A and Output of 5A.
$98.05 USD

Learn More

AccuEnergy AcuCT-5170R-2000:5A Press Open Split Core Current Transformer, 2000A:5A, 5.1 x 7" AcuCT-5170R-2000:5A 88123
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 5.1 x 7". Has a Current Input of 2000A and Output of 5A.
$345.00 USD

Learn More

AccuEnergy AcuCT-3163-2000:5 Split Core Current Transformer, 2000:5A, 3.15 x 6.3" AcuCT-3163-2000:5 19301
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 3.15 x 6.3". Has a Current Input of 2000A and Output of 5A.
$127.20 USD

Learn More

AccuEnergy AcuCT-4161R-2500:5A Press Open Split Core Current Transformer, 2500A:5A, 4.1 x 6.1" AcuCT-4161R-2500:5A 88087
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 4.1 x 6.1". Has a Current Input of 2500A and Output of 5A.
$240.00 USD

Learn More

AccuEnergy AcuCT-3135R-1000:5A Press Open Split Core Current Transformer, 1000A:5A, 3.1 x 3.5" AcuCT-3135R-1000:5A 88033
High accuracy premium split-core current transformer with a unique press-open hinge is simpler and faster to install. Features a window size of 3.1 x 3.5". Has a Current Input of 1000A and Output of 5A.
$104.00 USD

Learn More

AccuEnergy AcuCT-0812-200:5 Split Core Current Transformer, 200:5A, 0.83 x 1.22" AcuCT-0812-200:5 19292
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 0.83 x 1.22". Has a Current Input of 200A and Output of 5A.
$53.60 USD

Learn More

AccuEnergy AcuCT-3163-2500:5 Split Core Current Transformer, 2500:5A, 3.15 x 6.3" AcuCT-3163-2500:5 87936
Light-weight and compact industrial standard split core 5A current transformers. Features a window size of 3.15 x 6.3". Has a Current Input of 2500A and Output of 5A.
$132.20 USD

Learn More

Acuvim X1 I/O Module for Acuvim-DL and Acuvim-EL Power Meters X1 8162
The X1 communications module adds 4 digital inputs and 2 digital outputs to Acuvim DL & EL power meters
$65.00 USD

Learn More

Acuvim X2 I/O Module for Acuvim-DL and Acuvim-EL Power Meters X2 8163
The X2 communications module adds 4 digital inputs, 2 digital outputs and RS485 communications to Acuvim DL & EL power meters.
$110.00 USD

Learn More

MODBUS RS485 to USB Adapter USB-RS485 6748
MODBUS RS485 to USB Adapter converts MODBUS data running via RS485 to USB for use on local PC.
$85.00 USD

Learn More

Acuvim REM-DES1 Remote Display for Acuvim DIN-Rail Mounted meters REM-DS1 9239
Acuvim DES-1 Remote Display unit for Acuvim II-Series & L-Series DIN-Rail mounted meters.
$115.00 USD

Learn More

Acuvim REM-DES2 Remote Display for Acuvim DIN-Rail Mounted meters REM-DS2 8623
Acuvim DES-2 Remote Display unit for Acuvim II-Series & L-Series DIN-Rail mounted meters.
$155.00 USD

Learn More

Hoffman 851FG Wall Mountable Enclosure with 1 x 1/4 DIN 851FG 6226
Hoffman Polycarbonate Wall Mountable Enclosure with 1 x 1/4 DIN opening. Hinged enclosure with locking accessory (92mm x 92mm).
$83.00 USD

Learn More

Flex-Core IKU8SC Shorting Block IKU8SC 15098
Shorting block with 8 terminals and cover for use in electrical applications.
$30.00 USD

Learn More

Flex-Core IKU6SC Shorting Block IKU6SC 6874
Shorting block with 6 terminals and cover for use in electrical applications.
$25.00 USD

Learn More

Flex-Core IKU4SC Shorting Block IKU4SC 11748
Shorting block with 4 terminals and cover for use in electrical applications.
$20.00 USD

Learn More

Flex-Core 3VTN-460-288-FF Potential Transformer 3VTN-460-288-FF 15095
3-Phase potential transformer for 288:120V line-to-neutral and 2.4:1 turns ratio. Comes complete with primary and secondary fuse
$615.00 USD

Learn More

Flex-Core 3VTL-460-480 Potential Transformer 3VTL-460-480 15090
3-Phase potential transformer for 480:120V line-to-line and 4:1 turns ratio.
$536.00 USD

Learn More

Flex-Core 3VTN-460-300-FF Potential Transformer 3VTN-460-300-FF 15096
3-Phase potential transformer for 300:120V line-to-neutral and 2.5:1 turns ratio. Comes complete with 1.5A primary and 1.6A secondary fuse
$615.00 USD

Learn More

Flex-Core 3VTN-460-069-FF Potential Transformer 3VTN-460-069-FF 15091
3-Phase potential transformer for 69.3:120V line-to-neutral and 0.58:1 turns ratio. Comes complete with 5A primary and 1.6A secondary fuse
$615.00 USD

Learn More

Flex-Core 3VTN-460-346-FF Potential Transformer 3VTN-460-346-FF 15097
3-Phase potential transformer for 346:120V line-to-neutral and 2.88:1 turns ratio. Comes complete with 1.5A primary and 1.6A secondary fuse
$615.00 USD

Learn More

Flex-Core 3VTN-460-120-FF Potential Transformer 3VTN-460-120-FF 15092
3-Phase potential transformer for 120:120V line-to-neutral and 1:1 turns ratio. Comes complete with 4A primary and 1.6A secondary fuse.
$615.00 USD

Learn More

Flex-Core 3VTL-460-120 Potential Transformer 3VTL-460-120 15087
3-Phase potential transformer for 120:120V line-to-line and 1:1 turns ratio.
$536.00 USD

Learn More

Flex-Core 3VTN-460-208-FF Potential Transformer 3VTN-460-208-FF 15093
3-Phase potential transformer for 208:120V line-to-neutral and 1.73:1 turns ratio. Comes complete with primary and secondary fuse.
$615.00 USD

Learn More

Flex-Core 3VTL-460-208 Potential Transformer 3VTL-460-208 14276
3-Phase potential transformer for 208:120V line-to-line and 1.73:1 turns ratio
$536.00 USD

Learn More

Flex-Core 3VTN-460-240-FF Potential Transformer 3VTN-460-240-FF 15094
3-Phase potential transformer for 240:120V line-to-neutral and 2:1 turns ratio. Comes complete with 2A primary and 1.6A secondary fuse
$615.00 USD

Learn More

Flex-Core 3VTL-460-240 Potential Transformer 3VTL-460-240 15088
3-Phase potential transformer for 240:120V line-to-line and 2:1 turns ratio.
$536.00 USD

Learn More

Flex-Core 3VTN-460-277-FF Potential Transformer 3VTN-460-277-FF 5884
3-Phase potential transformer for 277:120V line-to-neutral and 2.31:1 turns ratio. Comes complete with 2A primary and 1.6A secondary fuse
$615.00 USD

Learn More

Flex-Core 3VTL-460-288 Potential Transformer 3VTL-460-288 15089
3-Phase potential transformer for 288:120V line-to-line and 2.4:1 turns ratio
$536.00 USD

Learn More

Ask a question about the Acuvim-EL Series of Power Meters:

comments powered by Disqus

Review the Acuvim-EL Series of Power Meters

" data-description="Built for energy and facilities professional who need a low cost single/three phase non-revenue grade time-of-use meter. Available with LCD display or DIN Rail mount transducer (no display). All versions include MODBUS RS485 output.">